Abdulwahhab Essa Hamza

Dr. Abdulwahhab Essa Hamza


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2026 in Journal of King Saud University Computer and Information Sciences
Verified
Journal Article
Open access
PDF file
Badiea Abdulkarem Mohammed AlshaibaniBadiea Abdulkarem Mohammed Alshaibani
Badiea Abdulkarem Mohammed Alshaibani
Mahmood A. Al-ShareedaMahmood A. Al-Shareeda
Mahmood A. Al-Shareeda
AHAbdulwahhab Essa Hamza
Abdulwahhab Essa Hamza
Bilal Naji AlhasnawiBilal Naji Alhasnawi
Bilal Naji Alhasnawi
Raad Z. HomodRaad Z. Homod
Raad Z. Homod
IAIbrahim Mohammad Alreshidi
Ibrahim Mohammad Alreshidi
The Internet of Medical Things (IoMT) is defined by the connectivity that does exist between wearable sensors, implant devices and hospital information systems to a cloud based platforms allowing for real-time-healthcare data monitoring and clinical decision making driven by data. On the other hand, heterogeneity and limited resources of IoMT communication infrastructures enlarge considerably their attack surface on the cybersecurity side leading to critical challenges around patient safety, data integrity and system availability. This narrative review introduces a novel communication-centric IoMT threat taxonomy which would systematically overview vulnerabilities across the device, network, data, application and system-availability layers followed by analysis of inter-layer propagation and ultimately cross-layer propagation of threats to IoMT. PRISMA principles on literature selection permits transparency of methods. Well- this is to build a one comprehensive technical comparative evaluation report rather than descriptive surveys, especially if we replicate the above said references in relation with IoMT-specific Daggers and teeths flourished around classical cryptography, lightweight security primitives, AI-powered anomoly detection systems, Blockchain-based trusted architecture compositions rooted around post-quantum paradigms. From the analysis, it is concluded that lightweight cryptographic schemes and ECC-based authentication are still the most applicable communication protocols for resource-constrained medical devices while AI- and consortium-based blockchain architectures act as supplementary enhancements at the infrastructure level rather than as a substitute to secure communication protocols. Multiple real-life healthcare cyber incidents further emphasize the impact of infrastructure-enabled attacks in IoMT surroundings. This review is based on layered threat model, technical trade-off analysis, regulatory compliance mapping and empirical case studies to provide an implementation-aware design guide for enhancing resilience of the IoMT communication security design in accordance with regulations.

20 February 2026 in Applied Mechanics and Materials
Verified
Journal Article
Closed access
PDF file
AKAbbas Fadhil Kadhim
Abbas Fadhil Kadhim
AHAbdulwahhab Essa Hamza
Abdulwahhab Essa Hamza
Mahmood A. Al-ShareedaMahmood A. Al-Shareeda
Mahmood A. Al-Shareeda
KHKhalid Asaad Hashim
Khalid Asaad Hashim
NSNurfarhana Mohamad Sapiee
Nurfarhana Mohamad Sapiee
NBNorhafizah Burham
Norhafizah Burham
Medical storage systems are essential for ensuring the safety and efficacy of sensitive medical products such as pharmaceuticals and vaccines. These systems must maintain optimal environmental conditions, especially temperature, humidity, and security, to prevent spoilage and preserve product quality. However, conventional monitoring methods often rely on manual supervision and periodic inspections, which can result in human error, inefficiencies, and delayed responses to environmental changes. This study presents the design and validation of a smart, low-power medical storage monitoring system to overcome the limitations of traditional methods by providing real-time, remote oversight. An ESP32 microcontroller was integrated with temperature, humidity, and gas sensors to monitor the storage environment continuously. The system leverages Wi-Fi and Internet of Things (IoT) technology for remote data access and sends immediate mobile notifications upon detecting motion or anomalous environmental conditions. A camera was also incorporated to record video for enhanced security when detecting motion. The system's temperature readings demonstrated high accuracy, with a linear slope of 1.0636 and a y-intercept of -1.9545 when validated against a reference thermometer across a 20°C to 30°C range. A high coefficient of determination, R 2 value of 0.9681, confirms that the system's measurements account for 96.81% of the variance in the reference values. Consistency assessments at intervals from 30 to 150 minutes revealed minimal fluctuations, with standard deviations of 0°C to 0.55°C for temperature, 0% to 1.64% RH for humidity, and 0% to 0.55% for gas levels of the volatile organic compounds (VOCs) such as CO2, indicating high stability. The entire system operates with a low power consumption of 3W. The developed IoT-based monitoring system offers a highly accurate, stable, and cost-effective solution for medical storage. Its real-time monitoring and alert capabilities significantly enhance the safety, efficacy, and security of stored medical products compared to conventional methods.