Andrea Faini

Dr. Andrea Faini

Department of Cardiovascular, Neural and Metabolic Sciences, Istituto Auxologico Italiano, IRCCS, 20149 Milan, Italy
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2012 in Hypertension
Verified
Journal Article
Open access
PDF file
GSGiuseppe Schillaci
Giuseppe Schillaci
GBGrzegorz Bilo
Grzegorz Bilo
GPGiacomo Pucci
Giacomo Pucci
SLStéphane Laurent
Stéphane Laurent
IMIsabelle Macquin-Mavier
Isabelle Macquin-Mavier
GPGianfranco Parati
Gianfranco Parati
Short-term blood pressure (BP) variability predicts cardiovascular complications in hypertension, but its association with large-artery stiffness is poorly understood and confounded by methodologic issues related to the assessment of BP variations over 24 hours. Carotid-femoral pulse wave velocity (cfPWV) and 24-hour ambulatory BP were measured in 911 untreated, nondiabetic patients with uncomplicated hypertension (learning population) and in 2089 mostly treated hypertensive patients (83% treated, 25% diabetics; test population). Short-term systolic BP (SBP) variability was calculated as the following: (1) SD of 24-hour, daytime, or nighttime SBP; (2) weighted SD of 24-hour SBP; and (3) average real variability (ARV), that is, the average of the absolute differences between consecutive SBP measurements over 24 hours. In the learning population, all of the measures of SBP variability showed a direct correlation with cfPWV (SD of 24-hour, daytime, and nighttime SBP, r =0.17/0.19/0.13; weighted SD of 24-hour SBP, r =0.21; ARV, r =0.26; all P <0.001). The relationship between cfPWV and ARV was stronger than that with 24-hour, daytime, or nighttime SBP (all P <0.05) and similar to that with weighted SD of 24-hour SBP. In the test population, ARV and weighted SD of 24-hour SBP had stronger relationships with cfPWV than SD of 24-hour, daytime, or nighttime SBP. In both populations, SBP variability indices independently predicted cfPWV along with age, 24-hour SBP, and other factors. We conclude that short-term variability of 24-hour SBP shows an independent, although moderate, relation to aortic stiffness in hypertension. This relationship is stronger with measures of BP variability focusing on short-term changes, such as ARV and weighted 24-hour SD.

1 November 2005 in American Journal of Kidney Diseases
Verified
Journal Article
Closed access
PDF file
SGSimonetta Genovesi
Simonetta Genovesi
DPDaniela Pogliani
Daniela Pogliani
AFAndrea Faini
Andrea Faini
MVMaria G. Valsecchi
Maria G. Valsecchi
ARAlessandra Riva
Alessandra Riva
AVAntonio Vincenti
Antonio Vincenti

1 November 2013 in Autonomic Neuroscience
Verified
Journal Article
Closed access
Marco  Di RienzoMarco Di Rienzo
Marco Di Rienzo
EVEmanuele Vaini
Emanuele Vaini
Paolo CastiglioniPaolo Castiglioni
Paolo Castiglioni
GMGiampiero Merati
Giampiero Merati
PMPaolo Meriggi
Paolo Meriggi
GRGiovannibattista Rizzo
Giovannibattista Rizzo

24 May 2016 in Amyotrophic Lateral Sclerosis and Frontotemporal Degeneration
Verified
Journal Article
Closed access
BPBarbara Poletti
Barbara Poletti
FSFederica Solca
Federica Solca
LCLaura Carelli
Laura Carelli
FMFabiana Madotto
Fabiana Madotto
ALAnnalisa Lafronza
Annalisa Lafronza
VSVincenzo Silani
Vincenzo Silani
This study presents the Italian validation of the recently developed Edinburgh Cognitive and Behavioural ALS Screen (ECAS), a short screen for cognitive/behavioural alterations in patients with amyotrophic lateral sclerosis (ALS). We evaluated the psychometric properties of the ECAS Italian version in terms of reliability and convergent validity for both cognitive and behavioural features. Furthermore, we investigated the relationship with affective and clinical variables, in addition to ECAS usability and patients’ insight into cognitive/behaviour changes. Finally, correlations between genetic and cognitive/behavioural data were analysed. We recruited 107 patients with ALS. Normative data were collected on 248 healthy subjects. Participants were administered the ECAS and two standard cognitive screening tools (FAB, MoCA), two psychological questionnaires (BDI, STAI/Y) and an ad hoc usability questionnaire. The FBI was also carried out with caregivers. Results showed that the ECAS Italian version discriminated well between patients and controls. The most prevalent deficit occurred in executive functions and fluency. Correlations were observed between the ECAS and standard cognitive screening tools and between the ECAS carer interview and the FBI, supporting its full convergent validity. In conclusion, the ECAS Italian version provides clinicians with a rapid, feasible and sensitive tool, useful to identify different profiles of cognitive-behavioural impairment in ALS.

10 March 2011 in Blood
Verified
Journal Article
Closed access
PDF file
APAlberto Piperno
Alberto Piperno
SGStefania Galimberti
Stefania Galimberti
RMRaffaella Mariani
Raffaella Mariani
SPSara Pelucchi
Sara Pelucchi
GRGiulia Ravasi
Giulia Ravasi
FIfor the HIGHCARE investigators
for the HIGHCARE investigators
Iron is tightly connected to oxygen homeostasis and erythropoiesis. Our aim was to better understand how hypoxia regulates iron acquisition for erythropoiesis in humans, a topic relevant to common hypoxia-related disorders. Forty-seven healthy volunteers participated in the HIGHCARE project. Blood samples were collected at sea level and after acute and chronic exposure to high altitude (3400-5400 m above sea level). We investigated the modifications in hematocrit, serum iron indices, erythropoietin, markers of erythropoietic activity, interleukin-6, and serum hepcidin. Hepcidin decreased within 40 hours after acute hypoxia exposure (P < .05) at 3400 m, reaching the lowest level at 5400 m (80% reduction). Erythropoietin significantly increased (P < .001) within 16 hours after hypoxia exposure followed by a marked erythropoietic response supported by the increased iron supply. Growth differentiation factor-15 progressively increased during the study period. Serum ferritin showed a very rapid decrease, suggesting the existence of hypoxia-dependent mechanism(s) regulating storage iron mobilization. The strong correlation between serum ferritin and hepcidin at each point during the study indicates that iron itself or the kinetics of iron use in response to hypoxia may signal hepcidin down-regulation. The combined and significant changes in other variables probably contribute to the suppression of hepcidin in this setting.

1 August 2007 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
Paolo CastiglioniPaolo Castiglioni
Paolo Castiglioni
AFAndrea Faini
Andrea Faini
GPGianfranco Parati
Gianfranco Parati
Marco  Di RienzoMarco Di Rienzo
Marco Di Rienzo
Seismocardiogram (SCG) is the recording of body vibrations induced by the heart beat. SCG contains information on cardiac mechanics, in particular heart sounds and cardiac output. In this paper we present a new wearable device for SCG recordings during long term monitorings, and the results of a validation test in 4 subjects. The system is based on the integration of the MagIC smart shirt (i.e., a textile-based wearable system for the assessment of ECG and respiratory movements), and an external triaxial MEMS accelerometer positioned on the left clavicle. SCG was estimated as the average of accelerations occurred in each heart beat. The SCG components due to the valve closure and to recoil forces following the heart contraction (ballistocardiogram) were extracted by high-pass (>18 Hz) and band-pass (0.6-20 Hz) filters respectively. Then the difference between the I and J waves of the ballistocardiogram ( lI-Jl index, possibly related to the cardiac output) was identified by an ad-hoc procedure and compared with the model flow indirect estimation of cardiac output. Validation on 4 volunteers showed that: 1) our wearable system provides statistically consistent estimates of both heart- sound related vibrations and recoil movements; 2) reliable estimates of the II-Jl index can be obtained by considering about 1 minute of SCG recording in stationary conditions; and 3) changes of the II-Jl index during exercise correlate well with changes of cardiac output estimated by the model flow.