Dorian Audot

Dr. Dorian Audot

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2025 in Sports Biomechanics
Verified
Journal Article
Open access
ITIsobel Thompson
Isobel Thompson
DADorian Audot
Dorian Audot
MWMartin B. Warner
Martin B. Warner
JBJoseph Banks
Joseph Banks
OLOliver Logan
Oliver Logan
DHDominic Hudson
Dominic Hudson
Motion analysis technology is used in various settings to assess human kinematics. Assessing human movement underwater presents many challenges, making it important to understand measurement error associated with the setup and calibration of the system ensuring accuracy in resulting kinematics. This study assessed the accuracy across the entire domain of a submerged motion capture methodology. Six Qualisys cameras created an underwater capture volume of 6.9 × 2.1 × 2.1 m3. Average error levels were acceptable in four uncertainty trials (<± 5 mm error). By selecting an area of interest that excluded areas with low accuracy near domain borders, measurement error reduced by up to 0.13 mm, up to 1.27 mm lower than outside this area. Interpolated error indicated that intracyclic measurement error may alter measured kinematics by up to 13.80 mm, with error greater than 5 mm affecting over 50% of the kick cycle. Investigating error levels across the domain can inform researchers whether a recalibration is necessary or help to identify areas where high error levels would affect kinematics. This study highlights the need to investigate error levels across a motion capture domain, particularly when this is a large volume, to ensure results obtained from investigations are reliable.

24 October 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DADorian Audot
Dorian Audot
ITIsobel Thompson
Isobel Thompson
JBJoseph Banks
Joseph Banks
DHDominic A. Hudson
Dominic A. Hudson
MWMartin Warner
Martin Warner
OLOliver Logan
Oliver Logan
Underwater undulatory swimming (UUS) is a technique used in competitive swimming and its performance is usually associated with faster race times. Previous research mainly focused on maximal-effort UUS. It remains unclear how swimmers adjust their UUS technique to race-specific sub-maximal paces. This study investigated how swimmers naturally modified their UUS technique when tasked to swim at maximum effort, at a 100 m pace, and at a 200 m pace. Nine competitive male swimmers (World Aquatics points: 778±137) undertook multiple UUS trials at each prescribed pace in prone orientation. Kinematic data were captured using six underwater motion capture cameras, and nine key kinematic variables were calculated. The metrics were then analysed using repeated-measures ANOVA and correlation analyses. Results showed that kick frequency, toe delay, kick amplitude, and hip extension at peak toe vertical position were strongly affected by the pace. Moreover, toe delay appeared to be a good indicator of coordination and was strongly associated with changes in amplitude and frequency. Correlation analyses revealed the participants employed different coordination changes to achieve similar decreases in swimming velocity at the slower prescribed paces. These findings improve the knowledge of sub-maximal race-relevant UUS techniques while highlighting the importance of further investigating such paces.