Muscle spasticity, common in conditions such as cerebral palsy, spinal cord injury, and multiple sclerosis, is traditionally assessed using the Modified Ashworth Scale, which lacks consistency. This study evaluates near‐infrared spectroscopy (NIRS) as a non‐invasive tool for measuring muscle contraction intensity. Thirty‐seven healthy adults performed isometric contractions at varying intensities (15%, 30%, 45%, and 60% of maximal voluntary contraction), with NIRS sensors monitoring changes in the Tissue Oxygenation Index (TOI) and electromyography (EMG) measuring muscle activity. Results demonstrated a significant negative correlation between contraction intensity and ΔTOI, indicating that higher contraction levels resulted in greater reductions in muscle oxygenation. Additionally, a multinomial logistic regression model confirmed that TOI could reliably predict contraction intensity ( p < 0.001). This technique could provide real‐time, objective data for spasticity assessment, potentially improving treatment plans.
Continuous peripheral oxygen saturation (SpO2) monitoring can describe systemic oxygenation during exercise, but its value for identifying blood lactate threshold (LT) depends on the timing of recognizable signal changes. Two independent cohorts of 18 healthy adults completed the same incremental cycling protocol with forehead or fingertip pulse oximetry. We characterized SpO2 at key landmarks and throughout exercise and evaluated three changes: a decrease exceeding individual early-exercise variation, a rapid recent decline, and a sustained transition to a steeper decline. All detectors used only measurements available at each update. Event times were compared with Dmax and modified Dmax LT, distinguishing the sustained transition’s estimated breakpoint from its later detection. The first decrease typically preceded LT by 13–16 min. Rapid recent declines also showed substantial timing errors; requiring steeper declines reduced detection coverage. Sustained transitions were detected in 14/18 forehead and 13/18 fingertip recordings. Detection times were closer to LT than breakpoints, but median absolute detection errors remained 3.09–4.25 min across cohorts and LT definitions. Only 4–5 of 18 recordings per cohort had detection times within ±2 min of LT. Timing accuracy remained limited under alternative processing and detection settings. In a separate trajectory comparison, the fingertip cohort showed a larger SpO2 decline. Separate adjustments for exercise frequency and attained workload per kilogram of body mass reduced the estimated cohort difference, but the design could not isolate anatomical-site or sensor-configuration effects. Continuous SpO2 therefore characterized exercise-related oxygenation changes, but these three features had limited accuracy as stand-alone LT markers in healthy adults under this cycling protocol.
Conventional cardiopulmonary resuscitation (CPR) is guided primarily by process metrics that do not directly quantify cerebral hemodynamics or perfusion. Near-infrared spectroscopy (NIRS) provides continuous, non-invasive monitoring of regional tissue oxygenation and has emerged as a candidate modality for physiologic feedback during low-flow states. However, CPR applications vary across devices and signal processing. This scoping review maps how NIRS has been implemented during conventional CPR in humans and porcine models, with emphasis on instrumentation characteristics, signal processing, acquisition bandwidth, artifact handling, physiologic associations, and feasibility constraints. From 1048 records, 39 studies met the inclusion criteria. Most used forehead-based cerebral rSO2 monitoring (30/39). Rising cerebral oxygenation trajectories were consistently associated with return of spontaneous circulation (ROSC). In contrast, persistently low or non-increasing patterns were associated with non-ROSC, and absolute thresholds varied substantially across devices and studies. A minority of investigations derived compression-rate or waveform features from hemoglobin signals. Feasibility findings emphasized rapid probe placement without interrupting compressions but highlighted motion artifact, workflow constraints, and incomplete acquisition reporting. Overall, during conventional CPR, NIRS primarily serves as a dynamic monitor of oxygenation trends rather than a validated prognostic tool. Emerging waveform-based and hemodynamic analyses suggest the potential to evaluate CPR efficiency using perfusion-responsive optical features.