Miren Ostra

Dr. Miren Ostra

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Corrosion Science
Verified
Journal Article
Closed access
NIN. Imaz
N. Imaz
MOMiren Ostra
Miren Ostra
MVM. Vidal
M. Vidal
JDJ.A. Díez
J.A. Díez
MPMaria Sarret Pons
Maria Sarret Pons
Eva Garcia-LecinaEva Garcia-Lecina
Eva Garcia-Lecina

1 July 2018 in Talanta
Verified
Journal Article
Closed access
Maider VidalMaider Vidal
Maider Vidal
RGRosa Garcia-Arrona
Rosa Garcia-Arrona
ABAne Bordagaray
Ane Bordagaray
MOMiren Ostra
Miren Ostra
GAGorka Albizu
Gorka Albizu

14 February 2008 in The Analyst
Verified
Journal Article
Closed access
PDF file
MOMiren Ostra
Miren Ostra
CUCarlos Ubide
Carlos Ubide
MVMaider Vidal
Maider Vidal
JZJuan Zuriarrain
Juan Zuriarrain
A methodology is proposed to estimate the limit of detection (LOD) of analytical methods when multivariate calibration is applied. It tries to follow the same premises as the IUPAC methodology for univariate calibration. The mathematical support is given and algorithms such as partial least squares (PLS) regression, PLS2 and principal component regression (PCR) are used. Only multivariate raw data are used; that is, no surrogate univariate signal is deduced. Non-linearities are allowed. Near infrared (NIR) data of 5 component pseudo-gasoline samples together with simulated fluorescence synchronous spectra of binary mixtures (first order data) are used for evaluation. Experimental verification is performed using different kinds of data, namely: binary mixtures of bentazone and fenamiphos (very overlapped spectra, second order data) obtained by sequential injection (SI), and kinetic data of the reaction between the Fenton's reagent (FR) and pesticides such as atrazine, bentazone and alachlor (individual or binary mixtures, second order data). Results are always compared with independent methods previously proposed in the literature, based in the use of surrogate univariate signals. In general, similar results are found and no statistically significant differences seem to be present, except in a few cases when complex chemical systems are involved.

1 January 2016 in Surface and Coatings Technology
Verified
Journal Article
Closed access
MVM. Vidal
M. Vidal
MOMiren Ostra
Miren Ostra
NIN. Imaz
N. Imaz
Eva Garcia-LecinaEva Garcia-Lecina
Eva Garcia-Lecina
CUC. Ubide
C. Ubide

5 July 2004 in Analytica Chimica Acta
Verified
Journal Article
Closed access
GLG López-Cueto
G López-Cueto
MOMiren Ostra
Miren Ostra
CUC Ubide
C Ubide
JZJ Zuriarrain
J Zuriarrain

1 November 2011 in Analytica Chimica Acta
Verified
Journal Article
Closed access
MVM. Vidal
M. Vidal
JAJ.M. Amigo
J.M. Amigo
Rasmus BroRasmus Bro
Rasmus Bro
FBF. van Den Berg
F. van Den Berg
MOMiren Ostra
Miren Ostra
CUC. Ubide
C. Ubide