Songhua Liu

Dr. Songhua Liu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Neurocomputing
Verified
Journal Article
Closed access
SLSonghua Liu
Songhua Liu
CDCaiying Ding
Caiying Ding
FJFei Jiang
Fei Jiang
YWYan Wang
Yan Wang
BYBaoyong Yin
Baoyong Yin

22 February 2024 in Journal of Circuits, Systems and Computers
Verified
Journal Article
Closed access
XZXinglong Zhou
Xinglong Zhou
KYKuntao Ye
Kuntao Ye
SLSheng Li
Sheng Li
SLSonghua Liu
Songhua Liu

2 November 2026 in Pattern Recognition Letters
Verified
Journal Article
Closed access
QHQiuzhi Hao
Qiuzhi Hao
MCMeiling Cai
Meiling Cai
XYXiaoya Yang
Xiaoya Yang
JZJuanjuan Zhao
Juanjuan Zhao
SLSonghua Liu
Songhua Liu

1 June 2026 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
QHQiuzhi Hao
Qiuzhi Hao
MCMeiling Cai
Meiling Cai
YRYe Ren
Ye Ren
LZLijing Zhang
Lijing Zhang
SLSonghua Liu
Songhua Liu
Computational pathology models are sensitive to artifacts arising from tissue preparation and whole-slide imaging. Common artifacts—including tissue folds, uneven staining, ink markings, blur, and contamination—alter both structural and chromatic characteristics of histopathological images, adversely affecting model reliability. To address this, we present AC-AttnNet, a multi-color-space network for robust artifact classification. Input images are transformed into RGB (Red-Green-Blue), HSV (Hue-Saturation-Value), HED (via hematoxylin–eosin deconvolution), and CIELAB (L*a*b*) color spaces, from which features are extracted using attention-enhanced residual blocks. A cross-color attention module (CCAM) models inter-space feature dependencies through sample-adaptive 4 × 4 attention matrices, enabling dynamic fusion of color-domain representations. AC-AttnNet achieves a multi-seed mean test accuracy of 97.91 ± 0.16 % (best single run: 97.96%) and 99.10% validation accuracy on a breast histopathology artifact dataset with only 7.7 M parameters and 1.58G FLOPs. Cross-dataset evaluation demonstrates strong generalization with an average accuracy of 87.3%, outperforming AR-Classifier (81.1%) and ResNet-50 (76.7%). Ablation studies confirm that multi-color-space modeling improves accuracy by +0.72% over the RGB-only baseline, and CCAM fusion yields modest but consistent gains over static concatenation across seeds (+0.08% mean improvement), with stronger qualitative support from t-SNE silhouette improvement and Grad-CAM focus. These findings demonstrate the effectiveness of cross-color feature interaction for artifact classification and support the use of AC-AttnNet as a reliable component in computational pathology quality control and restoration pipelines.


9 October 2026 in Electronics
Verified
Journal Article
Open access
PDF file
XZXuesong Zhang
Xuesong Zhang
JZJuanjuan Zhao
Juanjuan Zhao
THTao Hu
Tao Hu
ZLZerui Liu
Zerui Liu
SLSonghua Liu
Songhua Liu
YQYan Qiang
Yan Qiang
Transjugular intrahepatic portosystemic shunt (TIPS) is an effective treatment for portal hypertension, but post-TIPS hepatic encephalopathy (HE) remains a major complication. Conventional clinical scores use limited clinical and biochemical variables and cannot fully characterize preoperative imaging phenotypes. Although contrast-enhanced abdominal computed tomography(CT) contains morphological, textural, and spatial cues, available datasets are small, CT sequences are redundant, and local details must be modeled together with broader context. We therefore propose Medical Global Zoom Mamba (MGZ Mamba). A medical visual invariance constraint stratifies CT slices by feature density using the nonzero-pixel ratio and gray-level entropy, allowing multiple training instances to be constructed from each patient sequence. A double-nested parallel aggregate attention module combines multi-receptive-field convolution with global channel recalibration, while a feature rearrangement 2D scan module introduces dynamic windows and spatial-neighborhood rearrangement alongside the original two-dimensional selective scan branch. In patient-level five-fold cross-validation on the Post-TIPS Hepatic Encephalopathy Dataset of Shanxi Medical University (HE-SMU), MGZ Mamba achieved 81.65% accuracy, 82.76% recall, 80.53% F1-score, and an ROC-AUC of 0.829. Relative to the strongest baseline for each metric, accuracy, recall, and F1-score increased by 0.41, 1.07, and 0.56 percentage points, respectively, and ROC-AUC increased by 0.007. These findings support MGZ Mamba as an imaging-based approach for preoperative risk stratification and may provide complementary evidence for clinical assessment and treatment planning.