A low-vision assessment (LVA) is central to developing a vision rehabilitation plan. However, access to LVAs is often limited by the quantity and geographic distribution of low-vision providers, as well as patient-centred transportation challenges. A tablet-based LVA tool kit, delivered virtually, has the potential to overcome many of these barriers. The purpose of this research was to validate a key component of the tablet-based tool kit – a commercially available iPad visual acuity (VA) test (Eye Chart Pro) iPad app – in a low-vision population. Participants with low vision (n = 26) and those who were normally sighted (n = 25) underwent VA testing with both the iPad VA test application and the Early Treatment Diabetic Retinopathy Study (ETDRS) chart. The VA data were compared using a t-test, linear regression and Bland–Altman analysis. There was no significant difference in the mean absolute difference in VA (log of minimum angle of resolution (logMAR)=0.11; p = 0.82). Eye Chart Pro and Standard ETDRS Chart measures were also not significantly different (p = 0.98). However, there were significant differences between test methods in the low-vision group and the normally sighted group (p > 0.0001 and p = 0.007, respectively). The Bland–Altman analysis showed a mean bias (difference) of –0.0005 logMAR between methods, and 95% limits of agreement of 0.298 and –0.299 logMAR. The ETDRS chart function on the Eye Chart Pro application can reliably measure VA across a range, from normally sighted patients to those with low vision.
PurposeCompetency-based medical education relies on a strong program of assessment, and quality comments play a vital role in ensuring its success. The goal of this study is to determine the effect of the timeliness of assessment completion on the quality of the feedback.Materials and methodsUsing the Quality of Assessment for Learning (QuAL) score 2478 assessments were evaluated. The assessments included those completed between July 2017 and December 2020 for 18 ophthalmology residents. Spearman correlation, Mann-Whitney U and Kruskal-Wallis tests were used to assess variations in QuAL scores based on the timeliness of assessment completion.ResultsThe timeliness of assessment completion ranged from 0 to 299 d with the mean time for completion being 3 d. As the delay increased, the QuAL score decreased. Feedback provided 4, 5, and 14 d post-encounter demonstrated statistically significant differences in the QuAL score. Additionally, there was a significant difference in the timeliness of feedback when there is no written comment.ConclusionsThis study demonstrates that the timeliness of assessment completion might have an effect on the quality of written feedback. Written feedback should be completed within 14 d of the encounter to optimize quantity and quality.
26 September 2020 in Journal of Telemedicine and Telecare
A low-vision assessment (LVA) is critical in developing a vision rehabilitation plan. A remotely delivered LVA that replicates a standard in-clinic assessment may bridge the gap for patients not accessing care due to the limited quantity and distribution of low-vision providers. Within an LVA, an accurate and consistent assessment of refraction error is an essential component. No system has currently been validated for the purposes of a remote LVA. The purpose of this study was to validate a commercially available portable refraction approach in a low-vision population. Low-vision patients (n = 26) or normally sighted patients (n = 25) underwent a refraction assessment using the Adaptica® 2WIN autorefractor, adaptor scope (Kaleidos) and VisionFit phoropter portable refraction devices, as well as a standard autorefractor (Huvitz) and phoropter (Haag-Streit). Refraction data between systems and populations were compared using intraclass correlations. Bland–Altman plots were used to assess the differences between devices. Spherical equivalent values were found to be reproducible between standard and experimental autorefraction devices (intraclass correlation coefficient (ICC) > 0.8) in both low-vision and normally sighted groups. Similarly, manifest refraction was highly consistent (ICC > 0.8) between devices in all groups. The Bland–Altman plots showed clinically acceptable mean differences of 0.701 between autorefraction methods and –0.116 between manifest refraction methods. The 2WIN/VisionFit system can reliably generate refraction values across a spectrum of errors in normally sighted and visually impaired people, and would be feasible to deliver remotely.
Our institution simultaneously transitioned all postgraduate specialty training programs to competency-based medical education (CBME) curricula. We explored experiences of CBME-trained residents graduating from five-year programs to inform the continued evolution of CBME in Canada. We utilized qualitative description to explore residents' experiences and inform continued CBME improvement. Data were collected from fifteen residents from various specialties through focus groups, interviews, and written responses. The data were analyzed inductively, using conventional content analysis. We identified five overarching themes. Three themes provided insight into residents' experiences with CBME, describing discrepancies between the intentions of CBME and how it was enacted, challenges with implementation, and variation in residents' experiences. Two themes - adaptations and recommendations - could inform meaningful refinements for CBME going forward. Residents graduating from CBME training programs offered a balanced perspective, including criticism and recognition of the potential value of CBME when implemented as intended. Their experiences provide a better understanding of residents' needs within CBME curricula, including greater balance and flexibility within programs of assessment and curricula. Many challenges that residents faced with CBME could be alleviated by greater accountability at program, institutional, and national levels. We conclude with actionable recommendations for addressing residents' needs in CBME.
This case study of an art education program for medical students examines the efficacy of different types of content and modes of delivery. Through the delivery of art analysis, art history, sculpting, and life drawing seminars, art educators were able to teach empathy, observation, and flexible thinking to first-year medical students. This interdisciplinary approach to museum education can be used across many contexts to complement existing curricula.
Objective The aim of the study is to compare performance and ease-of-use (EOU) of optic disk assessment using a smartphone direct ophthalmoscope attachment (D-EYE) to the gold standard direct ophthalmoscope (DO). Design The type of study involved is prospective, randomized, crossover, and educational trial. Participants The participants involved were first year medical students inexperienced in ophthalmoscopy. Methods Optic disks of standardized and volunteer patients were examined using the D-EYE and a conventional DO. Optic disk identification, EOU ratings of the devices, self-reported confidence level in their examination with the devices, and estimation of vertical cup-to-disk ratio (VCDR) were compared. Analyses included Chi-square tests, independent samples t-tests, correlations, and multivariable linear regression. Results Forty-four medical students voluntarily participated in the study. Students using the DO required more attempts (3.57 vs. 2.69, p = 0.010) and time (197.00 vs. 168.02 seconds, p = 0.043) to match the patient's fundus to the correct photograph. Overall EOU between the devices (6.40 vs. 4.79, p < 0.001) and overall confidence in examination (5.65 vs. 4.49, p = 0.003) were greater when using the D-EYE. There were no statistically significant differences in accuracy of VCDR estimations between the two ophthalmoscopes. Conclusion Smartphone ophthalmoscopy could offer additional learning opportunities in medical education and may be considered in clinical practice by non-specialist physicians given its greater EOU and increased success in visualizing the optic disk.