Jiazheng Sun

Mr. Jiazheng Sun


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2026 in Sensors
Verified
Journal Article
Open access
PDF file
CCCai Chen
Cai Chen
JSJiazheng Sun
Jiazheng Sun
DLDanyang Lv
Danyang Lv
CTChongxuan Tian
Chongxuan Tian
SLShuxian Li
Shuxian Li
Tao JingTao Jing
Tao Jing
Electroencephalogram (EEG)-based biometric sensing provides a promising pathway for secure and user-specific human authentication, but practical deployment remains limited by cross-session non-stationarity and potentially optimistic evaluation protocols caused by window- or event-level leakage. This study developed a cross-session EEG biometric sensing framework using interpretable spectral features and target-session calibration, with trial-level non-overlapping data partitioning to prevent overlap between training, calibration, and blind-test sets. Multi-channel EEG events were segmented into non-overlapping 2 s windows and aggregated into event-level samples to ensure strict isolation among training, validation, calibration, and blind testing subsets. Power spectral density, differential entropy, and log-variance features were evaluated using support vector machine, linear discriminant analysis, logistic regression, random forest, and a compact convolutional neural network designed for EEG decoding (EEGNet). Both closed-set identification and biometric verification were assessed using Rank-N accuracy, cumulative match characteristic curves, macro-F1, equal error rate, area under the curve, and true acceptance rate (TAR) at fixed false acceptance rate (FAR) levels. In the in-house cross-day dataset, limited target-session calibration improved Rank-1 accuracy from 44.82% to 98.70% for support vector machine (SVM) and from 19.93% to 99.94% for linear discriminant analysis (LDA). SVM with differential entropy achieved an equal error rate (EER) of 1.04 ± 0.60%, area under the receiver operating characteristic curve (AUC) of 0.9985 ± 0.0008, and TAR@FAR = 0.1% of 98.44 ± 1.06%. External validation on the public multi-session motor imagery dataset confirmed the calibration benefit. These results demonstrate strong closed-set identification and score-level verification performance under a cohort-wide, calibration-assisted cross-session experimental protocol.

29 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
CCCai Chen
Cai Chen
DLDanyang Lv
Danyang Lv
JSJiazheng Sun
Jiazheng Sun
LLLijun Liu
Lijun Liu
SLShuxian Li
Shuxian Li
Tao JingTao Jing
Tao Jing
Objective: To compare electroencephalography (EEG)-based subject-identification and open-set rejection performance across experimental paradigms while examining model robustness and cross-session generalization. Methods: The M3CV database was analyzed across resting state, transient sensory stimulation, steady-state sensory stimulation, P300 Oddball, and motor execution. Closed-set identification was evaluated across feature representations, conventional machine-learning models, and raw-EEG deep-learning baselines. Open-set performance was further assessed using an identity-first leakage-free nested procedure with 60 enrolled identities, 15 development unknown identities, and 20 final-test unknown identities. Results: Under the P4 within-session protocol, transient sensory stimulation achieved the highest Rank-1 accuracy (98.10%). Differential entropy and shrinkage linear discriminant analysis achieved mean Rank-1 accuracies of 98.01% and 98.29%, respectively. Under leakage-free nested open-set evaluation, transient sensory stimulation achieved DIR@FPIR = 5%, DIR@FPIR = 1%, and AU-OSCR values of 91.75%, 77.32%, and 97.36%, respectively. Deep-learning analyses confirmed strong within-session identity discrimination but showed model-dependent open-set paradigm rankings. In contrast, strict cross-session transfer produced marked degradation across all model families, with Rank-1 accuracy falling to approximately 1.9–5.4% and verification AUC to approximately 0.53–0.56; unsupervised target normalization provided little recovery. Conclusions: EEG paradigms exhibited strong but largely session-dependent identity discriminability. Transient sensory stimulation provided the most favorable within-session open-set performance under the primary conventional framework, whereas cross-session variability dominated paradigm-dependent differences under zero-shot transfer.