Maximillian Soong

Dr. Maximillian Soong

Orthopedic Surgery, Lahey Clinic, Burlington, Massachusetts, USA
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2011 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
Maximillian SoongMaximillian Soong
Maximillian Soong
BEBrandon E Earp
Brandon E Earp
GBGavin Bishop
Gavin Bishop
ALAlbert Leung
Albert Leung
PBPhilip Blazar
Philip Blazar
Background: Flexor tendon injury is a recognized complication of volar plate fixation of distal radial fractures. A suspected contributing factor is implant prominence at the watershed line, where the flexor tendons lie closest to the plate. Methods: Two parallel series of patients who underwent volar locked plating of distal radial fractures from 2005 to 2008 and with at least six months of follow-up were retrospectively reviewed. Group 1 included seventy-three distal radial fractures that were treated by three orthopaedic hand surgeons with use of a single plate design at one institution, and Group 2 included ninety-five distal radial fractures that were treated by four orthopaedic hand surgeons with use of a different plate design at another institution. On the postoperative lateral radiographs, a line was drawn tangential to the most volar extent of the volar rim, parallel to the volar cortical bone of the radial shaft. Plates that did not extend volar to this line were recorded as Grade 0. Plates volar to the line, but proximal to the volar rim, were recorded as Grade 1. Plates directly on or distal to the volar rim were recorded as Grade 2. Results: In Group 1, the average duration of follow-up was thirteen months (range, six to forty-nine months). Three cases of flexor tendon rupture were identified among seventy-three plated radii (prevalence, 4%). Grade-2 plate prominence was found in two of the three cases with rupture and in forty-six cases (63%) overall. In Group 2, the average duration of follow-up was fifteen months (range, six to fifty-six months). There were no cases of flexor tendon rupture and no plates with Grade-2 prominence among ninety-five plated radii. Conclusions: Flexor tendon rupture after volar plating of the distal part of the radius is an infrequent but serious complication. The plate used in Group 1 is prominent at the watershed line of the distal part of the radius, which may increase the risk of tendon injury. We found no ruptures in Group 2, perhaps as a result of the lower profile of the plate. Further studies are needed before recommending one plate over another. Regardless of plate selection, surgeons should avoid implant prominence in this area. Level of Evidence: Therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence.

1 January 2011 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
Maximillian SoongMaximillian Soong
Maximillian Soong
RLRoderick van Leerdam
Roderick van Leerdam
TGThierry G. Guitton
Thierry G. Guitton
CGChristopher Got
Christopher Got
JKJulia Katarincic
Julia Katarincic
DRDavid Ring
David Ring

1 June 2018 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
CDC. Liam Dwyer
C. Liam Dwyer
Maximillian SoongMaximillian Soong
Maximillian Soong
AHAlice Hunter
Alice Hunter
JDJesse Dashe
Jesse Dashe
ETEric Tolo
Eric Tolo
NKN. George Kasparyan
N. George Kasparyan

11 December 2014 in HAND
Verified
Journal Article
Closed access
NENathan G. Everding
Nathan G. Everding
GBGavin B. Bishop
Gavin B. Bishop
CBChristopher M. Belyea
Christopher M. Belyea
Maximillian SoongMaximillian Soong
Maximillian Soong
Background: Open trigger finger release is generally considered a simple low-risk procedure. Reported complication rates vary widely from 1 to 43 %, mostly based on small studies. Our goal was to determine the incidence of complications in a large consecutive series, while also identifying potential risk factors. Methods: All open trigger finger releases performed from 2006 to 2009 by four fellowship-trained hand surgeons at a single institution were retrospectively reviewed. There were 795 digits released in 543 patients. Complications were defined as signs or symptoms requiring further treatment and/or considered unresolved by 1 month postoperatively. Complications requiring operative intervention were regarded as major. Multivariable analysis was performed to determine possible risk factors for complications. Results: There were 95 documented complications among 795 digits (12 %). The most common complications involved persistent pain, stiffness, or swelling, persistent or recurrent triggering, or superficial infection. Most were treated nonoperatively with observation, therapy, steroid injection, or oral antibiotics. There were 19 reoperations (2.4 %), mostly including revision release, tenosynovectomy, and irrigation and debridement. Male gender, sedation, and general anesthesia were independently associated with complications, while age, diabetes, hypothyroidism, recent injection, and concurrent procedures were not associated. Conclusions: Open trigger finger release is generally a low-risk procedure, although there is potential for complications, some requiring reoperation. Male gender, sedation, and general anesthesia may be associated with greater risk. Surgeons should be careful to thoroughly discuss the risk of both major and minor complications when counseling patients.

1 February 2006 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
Maximillian SoongMaximillian Soong
Maximillian Soong
JJJesse Jupiter
Jesse Jupiter
DRDaniel Rosenthal
Daniel Rosenthal

1 December 2008 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
Maximillian SoongMaximillian Soong
Maximillian Soong
CGChristopher Got
Christopher Got
JKJulia Katarincic
Julia Katarincic
EAEdward Akelman
Edward Akelman