Ismail hakki Baltacıoğlu

Dr. Ismail hakki Baltacıoğlu

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2009 in Operative Dentistry
Verified
Journal Article
Closed access
YBY. H. Bagis
Y. H. Bagis
IBIsmail hakki Baltacıoğlu
Ismail hakki Baltacıoğlu
SKS. Kahyaogullari
S. Kahyaogullari
Clinical Relevance: This in vitro study showed that the Silorane-based microhybrid resin composite system had no microleakage for wide Class II MOD restorations with oblique and vertical layering techniques.

16 November 2017 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
IBIsmail hakki Baltacıoğlu
Ismail hakki Baltacıoğlu
KOKaan Orhan
Kaan Orhan
Although numerous studies have used digital intraoral imaging, only a few studies have used photo-optical methods for the diagnosis of caries. Moreover, several limitations exist in terms of observers (experience and specialty) and the caries lesion itself. Hence, the aims of this study were to evaluate the diagnostic capability of near-infrared light transillumination (NILT) and PSP-Bitewing radiographs and to compare the interobserver and intraobserver differences in addition to observers’ experience level to detect early interproximal caries lesions in vivo. A total of 52 untreated posterior teeth with and without varying degrees of early interproximal carious lesions were included. Bitewing radiographs using digital phosphor plates (PSP-Bitewing) and NILT were used to clarify the diagnosis. An oral and maxillofacial radiologist and a restorative dentistry consultant evaluated the images twice. A separate appointment for clinical validation and restoration was made. Kappa coefficients were calculated to assess both intraobserver and interobserver agreements for each evaluation method. Scores obtained from PSP-Bitewing and NILT were compared with the clinical validation via receiver operating characteristic (ROC) analysis. No significant differences were found between PSP-Bitewing radiography and NILT for detecting early interproximal carious lesions with high average Az results. Both intraobserver and interobserver agreement values were relatively higher for NILT evaluation. The Az values increased at second evaluations for both caries detection methods. NILT examination has an appropriate sensitivity and diagnostic accuracy for detecting early interproximal caries lesions and can be considered as a method of choice for detecting caries without the use of ionizing radiation.

13 February 2024 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
IBIsmail hakki Baltacıoğlu
Ismail hakki Baltacıoğlu
GDGülbike Demirel
Gülbike Demirel
BÖBURCU ÖZTÜRK
BURCU ÖZTÜRK
FAFULYA AYDIN
FULYA AYDIN
KOKaan Orhan
Kaan Orhan
Background: The purpose of this study is to evaluate the marginal adaptation of bulk-fill resin composites with different viscosities (paste-like and flowable) in Class II restorations using micro-CT imaging. Methods: Forty extracted human molars were used. Mesial and distal Class II box cavities (approximately 3 mm x 3 mm x 4 mm) were prepared for each tooth, with cavity floors located 1 mm below the enamel-cementum junction. Following adhesive application, teeth were restored using eight different groups: Group XB: X-tra Base Bulk-fill Flowable (VOCO), Group XF: X-tra Fill Bulk-fill (VOCO), Group FB: Filtek Bulk-fill Posterior (3 M ESPE), Group FF: Filtek Bulk-fill Flowable (3 M ESPE), Group BB: Beautifil-Bulk (SHOFU), Group BF: Beautifil-Bulk Flowable (SHOFU), and Group CO: “as a control group”, Clearfil Majesty Posterior (KURARAY) and Group CF: “as a control group”, Clearfil Majesty Flow + Clearfil Majesty Posterior (KURARAY). The restored teeth underwent an aging protocol involving 1000 cycles in a water bath fluctuating between 5 ± 1.0 °C and 55 ± 1.0 °C. Post-aging, teeth were immersed in 50% silver nitrate solution for 24 h and then in a film developer solution for 8 h. Microleakage analysis was performed using micro-CT, evaluated with 3D Slicer software. A two-way ANOVA was employed for statistical analysis. Results: Two-way ANOVA results indicated significant effects of both viscosity (p < 0.0001) and composite type (p < 0.0001) on marginal adaptation. Viscosity analysis (comparing flowable and paste-like) revealed no significant differences in the FB-FF, XB-XF and BB-BF groups but significant differences in the and CO-CF group, with flowable type exhibiting less microleakage than paste-like type. Conclusions: The study suggests that while the viscosity of bulk-fill composites did not significantly affect marginal adaptation, the brand of bulk-fill composite did influence it.

22 August 2016 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ÖIÖzgür Irmak
Özgür Irmak
IBIsmail hakki Baltacıoğlu
Ismail hakki Baltacıoğlu
NUNuran Ulusoy
Nuran Ulusoy
YBYıldırım Hakan Bağış
Yıldırım Hakan Bağış
Air-drying of etched and rinsed dentin surface may force the exposed collagen fibrils to collapse. Blot-drying is an alternative method to wipe the excess water from the dentin surface without compromising the monomer penetration. Contemporary total etch adhesives contain ethanol/water or acetone as solvent in which resin monomers are dissolved. Solvent type of the adhesive system has an important role in bonding to dentin. An adhesive containing tertiary butanol as an alternative solvent has been in the market. Purpose of this study is to determine the shear bond strengths of three total-etch adhesives with different solvents (acetone, ethanol or tertiary butanol) applied to air or blot dried moist dentin. Sixty extracted non-carious human third molars were divided into three main groups according to solvent content of the adhesives [acetone based - One Step (OS, Bisco, IL, USA); ethanol/water based - Optibond Solo Plus (OB, Kerr, CA, USA); and tertiary butanol based - XP Bond (XP, Caulk/Dentsply, DE, USA)]. Each main group was divided into two groups according to drying methods (blot or air) (n = 10). Shear bond strengths (SBS) were measured. Data were analyzed by Student’s t test and Tukey HSD test (p < 0,05). XP showed highest SBS values in both drying methods applied (p < 0.05). Drying method did not influence the SBS in OS and OB (p > 0.05). XP-blot produced significantly higher SBS than XP-air (p < 0.05). Tertiary butanol based adhesive showed higher bond strength values than ethanol or acetone based adhesives. Blot drying of dentin improved the bond strength values of tertiary butanol based adhesive. Further research is necessary to determine in vivo and in vitro performance of tertiary butanol based adhesives.

1 January 2019 in Restorative Dentistry & Endodontics
Verified
Journal Article
Open access
GDGülbike Demirel
Gülbike Demirel
IBIsmail hakki Baltacıoğlu
Ismail hakki Baltacıoğlu
The aim of this study was to investigate the microshear bond strength (μSBS) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) restorative materials repaired with a composite resin. Four types of CAD-CAM hybrid block materials-Lava Ultimate (LA), Vita Enamic (VE), CeraSmart (CS), and Shofu Block HC (SH)-were used in this study, in combination with the following four adhesive protocols: 1) control: porcelain primer + total etch adhesive (CO), 2) Single Bond Universal (SB), 3) All Bond Universal (AB), and 4) Clearfil Universal Bond (CU). The μSBS of the composite resin (Clearfil Majesty Esthetic) was measured and the data were analyzed using two-way analysis of variance and the Tukey test, with the level of significance set at p < 0.05. The CAD-CAM block type and block-adhesive combination had significant effects on the bond strength values (p < 0.05). Significant differences were found between the following pairs of groups: VE/CO and VE/AB, CS/CO and CS/AB, VE/CU and CS/CU, and VE/AB and CS/AB (p < 0.05). The μSBS values were affected by hybrid block type. All tested universal adhesive treatments can be used as an alternative to the control treatment for repair, except the AB system on VE blocks (the VE/AB group). The μSBS values showed variation across different adhesive treatments on different hybrid CAD-CAM block types.

1 July 2016 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
IBIsmail hakki Baltacıoğlu
Ismail hakki Baltacıoğlu
HEHakan Eren
Hakan Eren
YYYasemin Yavuz
Yasemin Yavuz
kıvanç of kamburoğlukıvanç of kamburoğlu
kıvanç of kamburoğlu
Objective:To assess the in vitro diagnostic ability of CBCT images using 7 different display types in the detection of recurrent caries.Methods:Our study comprised 128 extracted human premolar and molar teeth. Eight (8) groups each containing 16 teeth were obtained as follows: 1: Black Class I (Occlusal) amalgam filling without caries; 2: Black Class I (Occlusal) composite filling without caries; 3: Black Class II (Proximal) amalgam filling without caries; 4: Black Class II (Proximal) composite filling without caries; 5: Black Class I (Occlusal) amalgam filling with caries; 6: Black Class I (Occlusal) composite filling with caries; 7: Black Class II (Proximal) amalgam filling with caries; 8: Black Class II (Proximal) composite filling with caries. Teeth were imaged using 100 × 90 mm Field of View (FOV) at 3 different voxel sizes of a CBCT unit (Planmeca Promax 3D Proface, Helsinki, Finland). CBCT TIFF images were opened and viewed using custom-designed software for computers on different display types. In...