Andreas Weber

Mr. Andreas Weber

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AWAndreas Weber
Andreas Weber
Jagoba IturriJagoba Iturri
Jagoba Iturri
RBRafael Benitez
Rafael Benitez
SZSpela Zemljic-Jokhadar
Spela Zemljic-Jokhadar
Jose Luis Toca-HerreraJose Luis Toca-Herrera
Jose Luis Toca-Herrera
The interest in studying the mechanical and adhesive properties of cells has increased in recent years. The cytoskeleton is known to play a key role in cell mechanics. However, the role of the microtubules in shaping cell mechanics is not yet well understood. We have employed Atomic Force Microscopy (AFM) together with confocal fluorescence microscopy to determine the role of microtubules in cytomechanics of Human Umbilical Vein Endothelial Cells (HUVECs). Additionally, the time variation of the adhesion between tip and cell surface was studied. The disruption of microtubules by exposing the cells to two colchicine concentrations was monitored as a function of time. Already, after 30 min of incubation the cells stiffened, their relaxation times increased (lower fluidity) and the adhesion between tip and cell decreased. This was accompanied by cytoskeletal rearrangements, a reduction in cell area and changes in cell shape. Over the whole experimental time, different behavior for the two used concentrations was found while for the control the values remained stable. This study underlines the role of microtubules in shaping endothelial cell mechanics.

1 January 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
JGJuan Carlos Gil-Redondo
Juan Carlos Gil-Redondo
AWAndreas Weber
Andreas Weber
BZBarbara Zbiral
Barbara Zbiral
MVMaria Vivanco
Maria Vivanco
Jose Luis Toca-HerreraJose Luis Toca-Herrera
Jose Luis Toca-Herrera
Cells sense stiffness of surrounding tissues and adapt their activity, proliferation, motility and mechanical properties based on such interactions. Cells probe the stiffness of the substrate by anchoring and pulling to their surroundings, transmitting force to the extracellular matrix and other cells, and respond to the resistance they sense, mainly through changes in their cytoskeleton. Cancer and other diseases alter stiffness of tissues, and the response of cancer cells to this stiffness can also be affected. In the present study we show that MCF-7 breast cancer cells seeded on polyacrylamide gels have the ability to detect the stiffness of the substrate and alter their mechanical properties in response. MCF-7 cells plated on soft substrates display lower stiffness and viscosity when compared to those seeded on stiffer gels or glass. These differences can be associated with differences in the morphology and cytoskeleton organisation, since cells seeded on soft substrates have a round morphology, while cells seeded on stiffer substrates acquire a flat and spread morphology with formation of actin filaments, similar to that observed when seeded on glass. These findings show that MCF-7 cells can detect the stiffness of the surrounding microenvironment and thus, modify their mechanical properties.

20 May 2019 in Microscopy Research and Technique
Verified
Journal Article
Open access
PDF file
AWAndreas Weber
Andreas Weber
Jagoba IturriJagoba Iturri
Jagoba Iturri
RBRafael Benitez
Rafael Benitez
Jose Luis Toca-HerreraJose Luis Toca-Herrera
Jose Luis Toca-Herrera
Atomic force microscopy (AFM) is today an established tool in imaging and determination of mechanical properties of biomaterials. Due to their complex organization, those materials show intricate properties such as viscoelasticity. Therefore, one has to consider that the loading rate at which the sample is probed will lead to different mechanical response (properties). In this work, we studied the dependence of the mechanical properties of endothelial cells on the loading rate using AFM in force spectroscopy mode. We employed a sharp, four‐sided pyramidal indenter and loading rates ranging from 0.5 to 20 μm/s. In addition, by variation of the load (applied forces from 100 to 10,000 pN), the dependence of the cell properties on indentation depth could be determined. We then showed that the mechanical response of endothelial cells depends nonlinearly on the loading rate and follows a weak power‐law. In addition, regions of different viscous response at varying indentation depth could be determined. Based on the results we obtained, a general route map for AFM users for design of cell mechanics experiments was described.

23 June 2022 in Microscopy Research and Technique
Verified
Journal Article
Open access
AWAndreas Weber
Andreas Weber
RBRafael Benitez
Rafael Benitez
Jose Luis Toca-HerreraJose Luis Toca-Herrera
Jose Luis Toca-Herrera
Cells are complex, viscoelastic bodies. Their mechanical properties are defined by the arrangement of semiflexible cytoskeletal fibers, their crosslinking, and the active remodeling of the cytoskeletal network. Atomic force microscopy (AFM) is an often‐used technique for the study of cell mechanics, enabling time‐ and frequency‐dependent measurements with nanometer resolution. Cells exhibit time‐dependent deformation when stress is applied. In this work, we have investigated the stress relaxation of HeLa cells when subjected to a constant strain. We have varied the applied force (1, 2, 4, and 8 nN) and pause time (1, 10, and 60 s) to check for common assumptions for the use of models of linear viscoelasticity. Then, we have applied three models (standard linear solid, five element Maxwell, power law rheology) to study their suitability to fit the datasets. We show that the five element Maxwell model captures the stress relaxation response the best while still retaining a low number of free variables. This work serves as an introduction and guide when performing stress relaxation experiments on soft matter using AFM.Research Highlights: Cells exhibit linear viscoelastic properties when subjected to stress relaxation measurements at the studied different forces and times. The stress relaxation is best described by a five element Maxwell model. All three used models capture a softening and fluidization of cells when disrupting actin filaments.

Verified
Journal Article
Open access
PDF file
Jagoba IturriJagoba Iturri
Jagoba Iturri
AWAndreas Weber
Andreas Weber
AMAlberto Moreno-Cencerrado
Alberto Moreno-Cencerrado
MVMaria Vivanco
Maria Vivanco
RBRafael Benitez
Rafael Benitez
Jose Luis Toca-HerreraJose Luis Toca-Herrera
Jose Luis Toca-Herrera
Atomic force microscopy (AFM) combined with fluorescence microscopy has been used to quantify cytomechanical modifications induced by resveratrol (at a fixed concentration of 50 µM) in a breast cancer cell line (MCF-7) upon temporal variation. Cell indentation methodology has been utilized to determine simultaneous variations of Young’s modulus, the maximum adhesion force, and tether formation, thereby determining cell motility and adhesiveness. Effects of treatment were measured at several time-points (0–6 h, 24 h, and 48 h); longer exposures resulted in cell death. Our results demonstrated that AFM can be efficiently used as a diagnostic tool to monitor irreversible morpho/nano-mechanical changes in cancer cells during the early steps of drug treatment.

25 June 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MSMaria Sumarokova
Maria Sumarokova
Jagoba IturriJagoba Iturri
Jagoba Iturri
AWAndreas Weber
Andreas Weber
MMMaria Maares
Maria Maares
CKClaudia Keil
Claudia Keil
Jose Luis Toca-HerreraJose Luis Toca-Herrera
Jose Luis Toca-Herrera
Mucins, the main component of the mucus secretions of goblet and epithelial cells, are known for exhibiting a different behaviour in accordance with their surrounding environment (i.e. among others the environmental pH), which induces a drastic change in their measured mechanical properties. In this work, we have first employed Atomic Force Microscopy (AFM) in Force Spectroscopy mode to evaluate the adhesion of porcine mucin films at the nanoscale, and the changes caused in this particular factor by a pH variation between 7.0 and 4.0, both quite common values in biological conditions. Measurements also involved additional varying factors such as the indenting tip chemistry (hydrophobic vs hydrophilic), its residence time on the measured film (0, 1 and/or 2 seconds), and increasing pulling rates (ranging from 0.1 up to 10 µm/s). A second approach regarded the macroscale behaviour of the films, due to their potential applicability in the development of a new set of stimuli-responsive biomaterials. This was possible by means of complementary Wilhelmy plate method (to test the wetting properties) and cell proliferation studies on films previously exposed to the corresponding pH solution. According to our results, treatment with lowest pH (4.0) provides porcine mucin with a more hydrophilic character, showing a much stronger adhesion for analogous chemistries, as well as enhanced capability for cell attachment and proliferation, which opens new pathways for their future use and consideration as scaffold-forming material.