This paper proposes a system made up of four subsystems connected in sequence. The first and third subsystems each have one unit, the second has two, and the fourth has three. Every subsystem operates in parallel and is governed by the K-Out-of-n:G rule. Nonetheless, each subsystem needs at least one operational unit in order for the system to work. While a unit’s failure has an exponential distribution, repair is simulated using a general distribution and a distribution from the Gumbel–Hougaard family of copula. This study’s primary objective is to assess and contrast the system performance while our system is running under these two different repair policies. The problem is solved by combining the supplementary variable technique with Laplace transforms. We use reliability metrics to assess system performance. The second objective of this study is to present a reduction approach plan aimed at improving the overall reliability metrics of our system.
Wireless Sensor Networks (WSNs) deployed in agricultural and industrial environments require high reliability to ensure continuous monitoring and data transmission. This study presents a reliability analysis of a hybrid WSN system comprising four series-connected subsystems: (1) the central processing unit, (2) sensor nodes in cluster A, (3) sensor nodes in cluster B, and (4) communication relay units. The system operates under a k-out-of-n: G mechanism, where subsystems 2 and 3 require at least one operational unit, while subsystem 4 requires at least two. Whereas unit failures follow exponential distributions, repair processes are modeled using either general distributions or Gumbel–Hougaard copula-based approaches to capture dependencies among multiple repair units. Using Laplace transforms and supplementary variable techniques, we evaluate system reliability metrics and demonstrate that copula-based repair strategies significantly improve availability and the expected profit function. Furthermore, we propose a reduction technique governed by a factor that decreases component failure rates, thereby enhancing overall system reliability relative to the baseline configuration.
This work offers a reliability framework for a five-subsystem hybrid series-parallel system representing smart factory monitoring infrastructure under heat and vibration stressors. A central programmable logic controller (1-out-of-1), pressure and temperature sensors (2-out-of-5), wireless communication units (2-out-of-4), solar power modules (3-out-of-6), and a cold standby database server (1-out-of-2) are connected in series. Unit failures are modeled using exponential distributions with component-specific failure rates and two environmental failure rates for thermal stress () and vibration stress () which go beyond the single-parameter models used in prior research. Repair of degraded states is governed by general distributions. The Gumbel–Hougaard copula family deals with total failure states, permitting positive repair time dependence due to common maintenance resources and environmental recovery. The state probabilities are obtained in closed form by using Laplace transforms and the supplementary variable method. Those state probabilities are used to find system availability, reliability, , sensitivity, indices and profit for three cases: copula-based repair, general distribution repair and a reduction technique with parameter . Numerical analysis reveals steady state availability of 96.80%when using copula repair, and 99.35% when using the reduction technique ( = 0.2). Sensitivity analysis reveals that the solar power module subsystem is the main cause of degradation, however cost analysis reveals that proactive quality enhancement is more profitable than reactive repair options at all maintenance expenditure levels.