Since the introduction of the 13-valent pneumococcal conjugate vaccine, a number of studies have demonstrated the limited efficacy of the pneumococcal serotype 3 component of this vaccine. Evidence from seven countries (Denmark, France, Greece, Portugal, Sweden, UK, US) shows limited or no effectiveness of the 13-valent pneumococcal conjugate vaccine against serotype 3 invasive pneumococcal disease and carriage. The serotype 3 capsule has some unique characteristics that may serve to explain this lack of efficacy—capsular polysaccharide is abundantly expressed, leading to a greater thickness of capsule, and free capsular polysaccharide may be released during growth. The serotype 3 component of the Luminex multiplex assay demonstrates inferior inter-laboratory reproducibility than other components and results may not be reliable. This communication outlines this evidence and discusses whether it is necessary to include serotype 3 in the assay in the future.
8 February 2021 in Diagnostic and Prognostic Research
Background: The aim of RApid community Point-of-care Testing fOR COVID-19 (RAPTOR-C19) is to assess the diagnostic accuracy of multiple current and emerging point-of-care tests (POCTs) for active and past SARS-CoV2 infection in the community setting. RAPTOR-C19 will provide the community testbed to the COVID-19 National DiagnOstic Research and Evaluation Platform (CONDOR). Methods: RAPTOR-C19 incorporates a series of prospective observational parallel diagnostic accuracy studies of SARS-CoV2 POCTs against laboratory and composite reference standards in patients with suspected current or past SARS-CoV2 infection attending community settings. Adults and children with suspected current SARS-CoV2 infection who are having an oropharyngeal/nasopharyngeal (OP/NP) swab for laboratory SARS-CoV2 reverse transcriptase Digital/Real-Time Polymerase Chain Reaction (d/rRT-PCR) as part of clinical care or community-based testing will be invited to participate. Adults (≥ 16 years) with suspected past symptomatic infection will also be recruited. Asymptomatic individuals will not be eligible. At the baseline visit, all participants will be asked to submit samples for at least one candidate point-of-care test (POCT) being evaluated (index test/s) as well as an OP/NP swab for laboratory SARS-CoV2 RT-PCR performed by Public Health England (PHE) (reference standard for current infection). Adults will also be asked for a blood sample for laboratory SARS-CoV-2 antibody testing by PHE (reference standard for past infection), where feasible adults will be invited to attend a second visit at 28 days for repeat antibody testing. Additional study data (e.g. demographics, symptoms, observations, household contacts) will be captured electronically. Sensitivity, specificity, positive, and negative predictive values for each POCT will be calculated with exact 95% confidence intervals when compared to the reference standard. POCTs will also be compared to composite reference standards constructed using paired antibody test results, patient reported outcomes, linked electronic health records for outcomes related to COVID-19 such as hospitalisation or death, and other test results. Discussion: High-performing POCTs for community use could be transformational. Real-time results could lead to personal and public health impacts such as reducing onward household transmission of SARS-CoV2 infection, improving surveillance of health and social care staff, contributing to accurate prevalence estimates, and understanding of SARS-CoV2 transmission dynamics in the population. In contrast, poorly performing POCTs could have negative effects, so it is necessary to undertake community-based diagnostic accuracy evaluations before rolling these out. Trial registration: ISRCTN, ISRCTN14226970
Objective: To measure the association between self-reported signs and symptoms and SARS-CoV-2 seropositivity. Design: Cross-sectional study of three key worker groups. Setting: Six acute NHS hospitals and two Police and Fire and Rescue sites in England. Participants: Individuals were recruited from three streams: (A) Police and Fire and Rescue services (n = 1147), (B) healthcare workers (n = 1546) and (C) healthcare workers with previously positive virus detection (n = 154). Main outcome measures: Detection of anti-SARS-CoV-2 antibodies in plasma. Results: 943 of the 2847 participants (33%) reported belief they had had COVID-19, having experienced compatible symptoms (including 152 from Stream C). Among individuals reporting COVID-19 compatible symptoms, 466 (49%) were seronegative on both Nucleoprotein (Roche) and Spike-protein (EUROIMMUN) antibody assays. However, among the 268 individuals with prior positive SARS-CoV-2 tests, of whom 96% reported symptoms with onset a median of 63 days (IQR 52 – 75 days) prior to venesection, Roche and EUROIMMUN assays had 96.6% (95% CI 93.7% – 98.2%) and 93.3% (95% CI 89.6% – 95.7%) sensitivity respectively. Symptomatic but seronegative individuals had significantly earlier symptom onset dates than the symptomatic seropositive individuals, shorter illness duration and a much lower anosmia reporting frequency. Conclusions: Self-reported belief of COVID-19 was common among our frontline worker cohort. About half of these individuals were seronegative, despite a high sensitivity of serology in this cohort, at least in individuals with previous positive PCR results. This is compatible with non-COVID-19 respiratory disease during the COVID-19 outbreak having been commonly mistaken for COVID-19 within the key worker cohort studied. What is already known on this topic: Screening for SARS-CoV-2 antibodies is under way in some key worker groups; however, how this adds to self-reported COVID-19 illness is unclear. There are limited studies that investigate the association between self-reported belief of COVID-19 illness and seropositivity. What this study adds: About one third of a large cohort of key frontline workers believed they had had COVID-19 infection. In around half of these there was no serological evidence of infection. Individuals who believed they had previous infection, but were seronegative, differed systematically from the seropositive individuals: disordered sense of taste and smell was less common, illness duration was shorter, and reported onset of illness commonly predated the main COVID-19 epidemic in the UK. Although some individuals with previous COVID-19 may be seronegative, among symptomatic individuals who had PCR-confirmed SARS-CoV-2 within our cohort, sensitivity of the two immunoassays used (Roche Elecsys ® and EUROIMMUN) exceeded 90%. Together, these data indicate that many key workers may falsely believe, based on symptomatic illness experienced during 2020, that they have had COVID-19. Further research investigating the relationship between antibody detection and protection from future infection, with and without a history of COVID-19 disease, will help define the role serological testing can play in clinical practice.
1 March 2023 in The Pediatric Infectious Disease Journal
Background: Antibodies are a measure of immunity after primary infection, which may help protect against further SARS-CoV-2 infections. They may also provide some cross-protection against SARS-CoV-2 variants. There are limited data on antibody persistence and, especially, cross-reactivity against different SARS-CoV-2 variants after primary infection in children. Methods: We initiated enhanced surveillance in 18 secondary schools to monitor SARS-CoV-2 infection and transmission in September 2020. Students and Staff provided longitudinal blood samples to test for variant-specific SARS-CoV-2 antibodies using in-house receptor binding domain assays. We recruited 1189 students and 1020 staff; 160 (97 students, 63 staff) were SARS-CoV-2 nucleocapsid-antibody positive at baseline and had sufficient serum for further analysis. Results: Most participants developed sustained antibodies against their infecting [wild-type (WT)] strain as well as cross-reactive antibodies against the Alpha, Beta and Delta variants but at lower titers than WT. Staff had significantly lower antibodies titers against WT as cross-reactive antibodies against the Alpha, Beta and Delta variants than students (all P < 0.01). In participants with sufficient sera, only 2.3% (1/43) students and 17.2% (5/29) staff had cross-reactive antibodies against the Omicron variant; they also had higher antibody titers against WT (3042.5; 95% confidence interval: 769.0–12,036.2) than those who did not have cross-reactive antibodies against the Omicron variant (680.7; 534.2–867.4). Conclusions: We found very high rates of antibody persistence after primary infection with WT in students and staff. Infection with WT induced cross-reactive antibodies against Alpha, Beta and Delta variants, but not Omicron. Primary infection with WT may not be cross-protective against the Omicron variant.
Background: Dried blood spot samples (DBS) provide an alternative sample type to venous blood samples for antibody testing. DBS are used by NHS for diagnosing HCV and by PHE for large scale HIV and Hepatitis C serosurveillance; the applicability of DBS based approaches to SARS-CoV-2 antibody detection is uncertain. Objective: To compare antibody detection in dried blood spot eluates using the Roche Elecsys ® immunoassay (index test) with antibody detection in paired plasma samples, using the same assay (reference test). Setting: One Police and one Fire & Rescue facility in England. Participants: 195 participants within a larger sample COVID-19 serodiagnostics study of keyworkers, EDSAB-HOME. Outcome Measures: Sensitivity and specificity of DBS (the index test) relative to plasma (the reference test), at an experimental cut-off; quality of DBS sample collected; estimates of relative sensitivity of DBS vs. plasma immunoassay in a larger population. Results: 18/195 (9.2%) participants tested positive using plasma samples. DBS sample quality varied markedly by phlebotomist, and low sample volume significantly reduced immunoassay signals. Using a cut-off of ten median absolute deviations above the immunoassay result with negative samples, sensitivity and specificity of DBS were 89.0% (95% CI 67.2, 96.9%) and 100.0% (95% CI 97.9, 100%) respectively compared with using plasma. The limit of detection for DBS is about 30 times higher than for plasma. Conclusion: DBS use for SARS-CoV-2 serology, though feasible, is insensitive relative to immunoassays on plasma. Sample quality impacts on assay performance. Alternatives, including the collection of capillary blood samples, should be considered for screening programs.