Christiano de Oliveira-Santos

Dr. Christiano de Oliveira-Santos


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2011 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
COChristiano de Oliveira-Santos
Christiano de Oliveira-Santos
PSPaulo Henrique Couto Souza
Paulo Henrique Couto Souza
SBSoraya de Azambuja Berti-Couto
Soraya de Azambuja Berti-Couto
LSLien Stinkens
Lien Stinkens
KMKristin Moyaert
Kristin Moyaert
RJReinhilde Jacobs
Reinhilde Jacobs

16 May 2012 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
COChristiano de Oliveira-Santos
Christiano de Oliveira-Santos
IRIzabel Regina Rubira-Bullen
Izabel Regina Rubira-Bullen
SMSolange A. C. Monteiro
Solange A. C. Monteiro
JLJorge Esquiche León
Jorge Esquiche León
RJReinhilde Jacobs
Reinhilde Jacobs

1 June 2011 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
COChristiano de Oliveira-Santos
Christiano de Oliveira-Santos
ACAna Lúcia Álvares Capelozza
Ana Lúcia Álvares Capelozza
MDMariela Siqueira Gião Dezzoti
Mariela Siqueira Gião Dezzoti
CRCássia Maria Fischer Rubira
Cássia Maria Fischer Rubira
MPMarcelo Lupion Poleti
Marcelo Lupion Poleti
IRIzabel Regina Rubira-Bullen
Izabel Regina Rubira-Bullen
The aim of this study was to assess the visibility of the MC in different regions on CBCT cross-sectional images. CBCT cross-sectional images of 58 patients (116 hemi-mandibles) were analyzed, and the visibility of the MC in different regions was assessed. The MC was clearly visible in 53% of the hemi-mandibles. Difficult and very difficult visualizations were registered in 25% and 22% of the hemi-mandibles, respectively. The visibility of the MC on distal regions was superior when compared to regions closer to the mental foramen. No differences were found between edentulous and tooth-bearing areas. The MC presents an overall satisfactory visibility on CBCT cross-sectional images in most cases. However, the discrimination of the canal from its surrounds becomes less obvious towards the mental foramen region when cross-sectional images are individually analyzed.

1 December 2015 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
Ruben PauwelsRuben Pauwels
Ruben Pauwels
LSL Seynaeve
L Seynaeve
JHJ C G Henriques
J C G Henriques
COChristiano de Oliveira-Santos
Christiano de Oliveira-Santos
PSP C Souza
P C Souza
RJReinhilde Jacobs
Reinhilde Jacobs
Objectives: To investigate the effect of tube current-exposure time (mAs) reduction on clinical and technical image quality for different CBCT scanners, and to determine preliminary minimally acceptable values for the mAs and contrast-to-noise ratio (CNR) in CBCT. Methods: A polymethyl methacrylate (PMMA) phantom and an anthropomorphic skull phantom,, containing a human skeleton embedded in polyurethane, were scanned using four CBCT devices, including seven exposure protocols. For all protocols, the mAs was varied within the selectable range. Using the PMMA phantom, the CNRAIR was measured and corrected for voxel size. Eight axial slices and one coronal slice showing various anatomical landmarks were selected for each CBCT scan of the skull phantom. The slices were presented to six dentomaxillofacial radiologists, providing scores for various anatomical and diagnostic parameters. Results: A hyperbolic relationship was seen between CNRAIR and mAs Similarly, a gradual reduction in clinical image quality was seen at lower mAs values; however, for several protocols, image quality remained acceptable for a moderate or large mAs reduction compared with the standard exposure setting, depending on the clinical application. The relationship between mAs, CNRAIR and observer scores was different for each CBCT device. Minimally acceptable values for mAs were between 9 and 70, depending on the criterion and clinical application. Conclusions: Although noise increased at a lower mAs, clinical image quality often remained acceptable at exposure levels below the manufacturer's recommended setting, for certain patient groups. Currently, it is not possible to determine minimally acceptable values for image quality that are applicable to multiple CBCT models.

1 April 2018 in International Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
RSR.J. da Silva
R.J. da Silva
CSC.V. Valadares Souza
C.V. Valadares Souza
GSG.A. Souza
G.A. Souza
GAG.M.B. Ambrosano
G.M.B. Ambrosano
DFDeborah Queiroz Freitas
Deborah Queiroz Freitas
COChristiano de Oliveira-Santos
Christiano de Oliveira-Santos

21 November 2012 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
TIThaís Sumie Nozu Imada
Thaís Sumie Nozu Imada
LFLuciana Maria Paes da Silva Ramos Fernandes
Luciana Maria Paes da Silva Ramos Fernandes
BCBruna Stuchi Centurion
Bruna Stuchi Centurion
COChristiano de Oliveira-Santos
Christiano de Oliveira-Santos
Heitor Marques HonórioHeitor Marques Honório
Heitor Marques Honório
IRIzabel Regina Rubira-Bullen
Izabel Regina Rubira-Bullen