To investigate the performance degradation patterns and underlying damage mechanisms of permeable concrete under freeze–thaw cycles in cold regions, permeable concrete with varying porosities was selected as the research subject. A total of 120 rapid low-temperature freeze–thaw cycles were conducted. The evolution of porosity, mass loss, skid resistance, permeability, and compressive strength was systematically analyzed. Exploratory numerical simulations, conducted under idealized assumptions, suggest that rising porosity may reduce effective thermal conductivity, extend phase-change duration, and amplify internal temperature gradients—trends that are consistent with the observed porosity-dependent frost damage but require experimental temperature validation for quantitative confirmation. With the increase in freeze–thaw cycles, mass loss and porosity continuously increase, while compressive strength and permeability gradually decrease. After 120 cycles, the mass loss of all specimen groups was below 1%, with compressive strength decreasing by 5.5% to 12.9%. Despite this, the specimens maintained good permeability and skid resistance. Numerical simulations indicate that permeable concrete exhibits a three-stage temperature response during both freezing and thawing processes. An increase in porosity reduces the material’s effective thermal conductivity, prolongs the phase transition duration, and intensifies the internal temperature gradient, thereby amplifying the thermo–mechanical coupling damage effects. Therefore, optimizing the pore structure is crucial for improving the long-term service performance of permeable pavements in cold regions.
Pulsating heat pipes (PHPs) beneath a battery cold plate operate with the evaporator above the condenser, so that vapour expands directly against gravity. This orientation is imposed by vehicle packaging, yet its internal flow has rarely been resolved. A closed-loop borosilicate glass PHP of 2 mm/3 mm bore charged with methanol was visualized at 960 frames per second at 17, 22 and 27 W and charged volume fractions of 8.5, 17.0 and 25.6 %, and modelled with a one-dimensional force balance. Eleven flow regimes are grouped into three families-evaporation froth (A), oscillation confined to the condenser and adiabatic sections (B) and turn-to-turn migration (C)-and mapped in the power/filling-ratio plane. Vapour pressure dominates the force balance at 0.12 N, twice the wall friction, while gravity contributes less than 5 %. The model reproduces the measured plug amplitude to within 0.013 m at low filling ratio. Thermal resistance rises from 1.13-1.43 K/W at 8.5 % to 2.11-3.85 K/W at 25.6 %, so underfilling is favourable here. The map allows dry-out and flooding to be diagnosed from the observed regime in gravity-suppressed PHP battery modules.