Over the past decade, PV power plants have increasingly contributed to power generation. However, PV power generation widely varies due to environmental factors; thus, the accurate forecasting of PV generation becomes essential. Meanwhile, weather data for environmental factors include many missing values; for example, when we estimated the missing values in the precipitation data of the Korea Meteorological Agency, they amounted to ~16% from 2015–2016, and further, 19% of the weather data were missing for 2017. Such missing values deteriorate the PV power generation prediction performance, and they need to be eliminated by filling in other values. Here, we explore the impact of missing data imputation methods that can be used to replace these missing values. We apply four missing data imputation methods to the training data and test data of the prediction model based on support vector regression. When the k-nearest neighbors method is applied to the test data, the prediction performance yields results closest to those for the original data with no missing values, and the prediction model’s performance is stable even when the missing data rate increases. Therefore, we conclude that the most appropriate missing data imputation for application to PV forecasting is the KNN method.
A Time-of-Use (TOU)-tariff scheme, helps residential customers to adjust their energy consumption voluntarily and reduce energy cost. The TOU tariff provides flexibility in demand, alleviate volatility caused by an increase in renewable energy in the power system. However, the uncertainty in the customer’s behavior, causes difficulty in predicting changes in residential demand patterns through the TOU tariff. In this study, the dissatisfaction model for each time slot is set as the energy consumption data of the customer. Based on the actual customer’s consumption pattern, the user sets up a model of dissatisfaction that enables aggressive energy cost reduction. In the proposed Home Energy Management System (HEMS) model, the efficient use of jointly invested offsite photovoltaic (PV) power generation is also considered. The optimal HEMS scheduling result considering the dissatisfaction, cost, and PV curtailment was obtained. The findings of this study indicate, that incentives are required above a certain EV battery capacity to induce EV charging for minimizing PV curtailment.
Rooftop photovoltaic (PV) systems are usually behind the meter and invisible to utilities and retailers and, thus, their power generation is not monitored. If a number of rooftop PV systems are installed, it transforms the net load pattern in power systems. Moreover, not only generation but also PV capacity information is invisible due to unauthorized PV installations, causing inaccuracies in regional PV generation forecasting. This study proposes a regional rooftop PV generation forecasting methodology by adding unauthorized PV capacity estimation. PV capacity estimation consists of two steps: detection of unauthorized PV generation and estimation capacity of detected PV. Finally, regional rooftop PV generation is predicted by considering unauthorized PV capacity through the support vector regression (SVR) and upscaling method. The results from a case study show that compared with estimation without unauthorized PV capacity, the proposed methodology reduces the normalized root mean square error (nRMSE) by 5.41% and the normalized mean absolute error (nMAE) by 2.95%, It can be concluded that regional rooftop PV generation forecasting accuracy is improved.
31 October 2021 in The Journal of Next-generation Convergence Technology Association
본 연구는 가상증강현실을 이용하여 재난적 문제해결의 사고과정을 뇌파의 진폭변화로 분석하였다. 안정 상태(I), 유도사인이 없는 미로 상황(II), 유도사인이 있는 미로 상황(III)으로 나누어 뇌파의 진폭의 변화를 연구하 였다. 대뇌두피의 뇌파전극의 부착부위는 좌우전두극(Fp1(Frontal-pole), Fp2), 좌우전두부(F(Frontal)3, F4), 좌우 중심부(C(Central)3, C4), 좌우 두정부(P(Parietal)3, P4)에 부착하고 측정하였다. 분석 결과 세 가지 반복측정에 걸친 관심변수의 다변량(multivariate) 평균 차는 유의하였다(F=2.861, p=0.048). 8개 측정변수 각각에 대한 단변 량(univariate) 검정의 경우에도 F3, F4 변수를 제외한 모든 변수가 반복측정 간 유의한 차이를 드러냈다. 그러나 반복측정별 대조(contrast)를 통해 C4 변수를 제외한 모든 변수에 있어 Ⅱ번과 Ⅲ번 상황의 차이는 유의하지 않 음을 관찰하였다. 본 연구는 재난적 상황에 문제해결과정을 뇌파분석으로 위기상황에 대뇌두피영역 변화의 기초자 료로 이용될 것이다
A Fourier neural operator (FNO) is one of the physics-inspired machine learning methods. In particular, it is a neural operator. In recent times, several types of neural operators have been developed, e.g., deep operator networks, Graph neural operator (GNO), and Multiwavelet-based operator (MWTO). Compared with other models, the FNO is computationally efficient and can learn nonlinear operators between function spaces independent of a certain finite basis. In this study, we investigated the bounding of the Rademacher complexity of the FNO based on specific group norms. Using capacity based on these norms, we bound the generalization error of the model. In addition, we investigated the correlation between the empirical generalization error and the proposed capacity of FNO. From the perspective of our result, we inferred that the type of group norms determines the information about the weights and architecture of the FNO model stored in the capacity. And then, we confirmed these inferences through experiments. Based on this fact, we gained insight into the impact of the number of modes used in the FNO model on the generalization error. And we got experimental results that followed our insights.