This paper presents a device used to measure and register temperature for long-term subsoil measurements in boreholes. The borehole of this study is located in Gijón (Asturias, Spain). The measurements were made through two fixed sets of sensors coupled to the geothermal pipe, constituting two independent installations: (a) a commercial device called “Hobo”, which uses TMCx-HD-specific sensors based on resistors with variable resistance; and (b) a device built by this research group, which uses DS12B20 Maxim sensors, a bus 1-wire, and a recording device based on a conventional Arduino board. Temperature was registered every 5 min across several years. These measurements were used to thermally characterize the subsoil, determining the apparent thermal diffusivity, and to study the thermo-hydrogeology of the Lower Jurassic Gijón’s formation made of Liassic limestones and dolomites. This work is part of the Q-Thermie group’s research called “Shallow Thermal Energy”.
The aim of the present study is to develop an apparatus for the measurement of the thermal conductivity of geothermal grouting materials. The apparatus, named MCT, is designed and constructed as a direct application of a mathematical model of heat transference for conduction in an infinite homogeneous isotropic medium using a linear heat source of infinite length, infinitesimal radius and radial heat flow. This application is known as the transient hot wire method. The apparatus mainly consists of a hot wire, a power supply, a temperature sensor and a datalogger. The commissioning of the developed apparatus is carried out by means of the calibration of the temperature sensor, as well as measurements of thermal conductivity using four reference samples whose thermal conductivity is known. Each of the reference samples is formed of two solid rectangular prisms of the same material and of the same dimensions. MCT is precise and accurate. In good experimental conditions the uncertainty of the measurements is within 10%. In addition, the MCT apparatus is light and with reduced dimensions.