Background: There is still little known regarding the effects of meniscus resection size on tibiofemoral stability. Purpose: To determine if partial medial meniscectomy of the posterior horn significantly alters tibiofemoral stability as measured by the anterior-posterior (AP) position and laxity of the medial femoral condyle. Study Design: Controlled laboratory study. Methods: Five cadaveric knees were dissected to the capsule, preserving all ligaments and the quadriceps tendon. Each specimen was first tested on a rig where the AP position and laxity of the medial femoral condyle were measured while a range of forces was applied from full extension to 90° of flexion. Magnetic resonance imaging (MRI) at 3 tesla was then performed for baseline measurements of the meniscus before partial meniscectomy. Arthroscopic partial medial meniscectomy aimed at 30% of the posterior horn was then performed, followed by repeat mechanical testing and MRI. The sequence was then repeated for arthroscopic partial meniscectomy aimed at 60% and 100% of the posterior horn of the medial meniscus. Results: The MRI analysis demonstrated that 22% ± 9% of the original width of the posterior horn was removed at the first resection, 46% ± 11% was removed at the second resection, and the third resection was 100% removal of the posterior horn for all specimens. After 22% resection, no significant difference in AP laxity was observed. A statistically significant increase in AP laxity was observed with 46% resection under a 500-N compressive load compared with the intact meniscus. After full resection, significant increases in AP laxity were observed under a 50-N compressive load compared with the intact and 22% and 46% resections. The 22% resection had similar AP positions as the intact knee, whereas the 46% resection and 100% removal of the posterior horn had statistically further posterior AP positions than the intact knee. Conclusion: Partial medial meniscectomy with ≥46% resection of the original width of the posterior horn significantly altered the AP position of the medial femoral condyle and also increased laxity. Clinical Relevance: These mechanical changes may lead to abnormal cartilage loading and early osteoarthritis.
28 January 2015 in Journal of Orthopaedic Research
The purposes of determining the motion of a total knee replacement in vitro are to characterize the stability and laxity characteristics and to predict the kinematic behavior of the total knee replacement when implanted. With this information, different total knee replacement designs can be compared, the stability of the implanted knee replacement with and without the retention of ligaments can be assessed, and tests can be formulated to measure the wear and deformation of the materials, the strength of the components, and the fixation to the bone. Initially, different ways are described for characterizing the kinematics of the natural knee. We propose a rationale for the kinematic testing of total knee replacements in vitro using mechanical tests. One of the key questions is whether there is an objective method of measuring the kinematics of a total knee replacement in vitro, which will relate to or predict its behavior in vivo.
Aims: This aim of this study was to assess the feasibility of designing and introducing generic 3D-printed instrumentation for routine use in total knee arthroplasty. Materials and Methods: Instruments were designed to take advantage of 3D-printing technology, particularly ensuring that all parts were pre-assembled, to theoretically reduce the time and skill required during surgery. Concerning functionality, ranges of resection angle and distance were restricted within a safe zone, while accommodating either mechanical or anatomical alignment goals. To identify the most suitable biocompatible materials, typical instrument shapes and mating parts, such as dovetails and screws, were designed and produced. Results: Before and after steam sterilization, dimensional analysis showed that acrylonitrile butadiene styrene could not withstand the temperatures without dimensional changes. Oscillating saw tests with slotted cutting blocks produced debris, fractures, or further dimensional changes in the shape of Nylon-12 and polymethylmethacrylate (MED610), but polyetherimide ULTEM 1010 was least affected. Conclusion: The study showed that 3D-printed instrumentation was technically feasible and had some advantages. However, other factors, such as whether all procedural steps can be accomplished with a set of 3D-printed instruments, the logistics of delivery, and the economic aspects, require further study. Cite this article: Bone Joint J 2019;101-B(7 Supple C):115–120