Hong Liang

Dr. Hong Liang


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Strategic Study of CAE
Verified
Journal Article
Open access
PDF file
XJXu Jianguo
Xu Jianguo
LKLiu Kaitai
Liu Kaitai
CBChen Bowen
Chen Bowen
JGJia Guang
Jia Guang
SRShao Ruitai
Shao Ruitai
DZDai Zheng
Dai Zheng

5 December 2022 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
JWJunzheng Wu
Junzheng Wu
HZHang Zhang
Hang Zhang
TLTong Lian
Tong Lian
YDYaling Ding
Yaling Ding
CSChunlei Song
Chunlei Song
HLHong Liang
Hong Liang

20 November 2022 in Journal of Cardiac Surgery
Verified
Journal Article
Open access
ZZZengxiao Zou
Zengxiao Zou
CWChaojie Wang
Chaojie Wang
WZWenqian Zhang
Wenqian Zhang
ZWZhixiong Wu
Zhixiong Wu
RZRongjun Zou
Rongjun Zou
Xiaoping FanXiaoping Fan
Xiaoping Fan
Acute type A aortic dissection involving the aortic sinus is often combined with varying degrees of aortic regurgitation, while the structure of the aortic valve is often undamaged. The aim of this study was to evaluate the clinical effects of reconstruction of the aortic sinus using patches in patients with acute type A aortic dissection. From January 2016 to December 2019, 52 patients with acute type A aortic dissection involving the aortic sinus were treated with aortic sinus reconstruction using pericardial or artificial vascular patches. The clinical and follow-up data were summarized. Bovine pericardial patches were used in 31 cases and artificial vascular patches were used in 21 cases for aortic sinus reconstruction. Cardiopulmonary bypass time was (250.4 ± 65.7) min, aortic cross clamp time was (143.7 ± 42.3) min, and hypothermic circulatory arrest time was (9.6 ± 8.1) min. Three patients died in hospital, with a mortality rate of 5.8%. Fifteen patients (28.8%) had mild postoperative aortic regurgitation. The follow-up duration was 40 ± 12 (range, 21-66) months. Five patients (10.2%) developed moderate to severe aortic regurgitation and 3 (6.1%) died during the follow-up period. The application of patches for aortic sinus reconstruction is a relatively easy method in aortic valve-sparing root reconstruction for acute type A aortic dissection involving the aortic sinus. The clinical and follow-up results are favorable.

13 March 2026 in iScience
Verified
Journal Article
Open access
CSCongyan Shu
Congyan Shu
JWJunzheng Wu
Junzheng Wu
YDYaling Ding
Yaling Ding
KCKerong Chen
Kerong Chen
HYHaisheng Yu
Haisheng Yu
YLYan Li
Yan Li
Although the COVID-19 pandemic is no longer considered an emergency, the ongoing spread of the virus poses a persistent threat to public health. COVID-19 poses a challenge to the system due to the risk of saturation and the associated economic burden. To assess changes in the anti-SARS-CoV-2 antibody profile, we analyzed nine batches of intravenous immunoglobulin (IVIG) prepared from plasma samples collected between November 2020 and June 2023. Antibody changes against SARS-CoV-2 spike, nucleocapsid, and membrane proteins, and neutralizing antibodies were measured. Antibody titers against wild-type SARS-CoV-2 and the three variants consistently increased. Furthermore, different IVIG batches demonstrated that antibody-dependent cellular cytotoxicity activity was correlated with anti-spike and neutralizing antibody titers. The anti-SARS-CoV-2 antibody titers fluctuated according to the progress of the pandemic and changes in COVID-19 vaccine coverage. Our research shows that immune cell-mediated virus elimination and the neutralizing effects of anti-SARS-CoV-2 antibodies underlie the therapeutic effects of IVIG.