Jordan M Prutkin

Dr. Jordan M Prutkin

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2014 in Circulation
Verified
Journal Article
Closed access
JPJordan M Prutkin
Jordan M Prutkin
MRMatthew R. Reynolds
Matthew R. Reynolds
HBHaikun Bao
Haikun Bao
JCJeptha P. Curtis
Jeptha P. Curtis
SASana M. Al-Khatib
Sana M. Al-Khatib
DUDaniel Z. Uslan
Daniel Z. Uslan
Background—: The rate of implantable cardioverter-defibrillator (ICD) infections has been increasing faster than that of implantation. We sought to determine the rate and predictors of ICD infection in a large cohort of Medicare patients. Methods and Results—: Cases submitted to the ICD Registry from 2006 to 2009 were matched to Medicare fee-for-service claims data using indirect patient identifiers. ICD infections occurring within 6 months of hospital discharge after implantation were identified by ICD-9 codes. Logistic regression was used to examine factors associated with risk of ICD infection. Of 200 909 implants, 3390 patients (1.7%) developed an ICD infection. The infection rate was 1.4%, 1.5%, and 2.0% for single, dual, and biventricular ICDs, respectively ( P <0.001). Generator replacement had a higher rate compared with initial implant (1.9% versus 1.6%, P <0.001). The factors associated with infection were adverse event during implant requiring reintervention (odds ratio [OR], 2.692; 95% confidence interval [CI], 2.304–3.145), previous valvular surgery (OR, 1.525; 95% CI, 1.375–1.692), reimplantation for device upgrade, malfunction, or manufacturer advisory (OR, 1.354; 95% CI, 1.196–1.533), renal failure on dialysis (OR, 1.342; 95% CI, 1.123–1.604), chronic lung disease (OR, 1.215; 95% CI, 1.125–1.312), cerebrovascular disease (OR, 1.172; 95% CI, 1.076–1.276), and warfarin (OR, 1.155; 95% CI, 1.060–1.257). Conclusions—: Patients who developed an ICD infection were more likely to have had peri-ICD implant complications requiring early reintervention, previous valve surgery, device replacement for reasons other than battery depletion, and increased comorbidity burden. Efforts should be made to carefully consider when to reenter the pocket at any time other than battery replacement.

25 March 2014 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
MWMariko Welch
Mariko Welch
DUDaniel Z. Uslan
Daniel Z. Uslan
AGArnold J. Greenspon
Arnold J. Greenspon
MSMuhammad Rizwan Sohail
Muhammad Rizwan Sohail
LBLarry M. Baddour
Larry M. Baddour
FIfor the MEDIC Investigators
for the MEDIC Investigators

2 November 2016 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
JHJason Huang
Jason Huang
KPKristen K. Patton
Kristen K. Patton
JPJordan M Prutkin
Jordan M Prutkin

1 September 2019 in Journal of Electrocardiology
Verified
Journal Article
Closed access
BWBrooks Walsh
Brooks Walsh
PMPeter Macfarlane
Peter Macfarlane
JPJordan M Prutkin
Jordan M Prutkin
SSStephen Wallner Smith
Stephen Wallner Smith


21 June 2014 in Current Cardiology Reports
Verified
Journal Article
Closed access
PDF file
HGH. Sawyer Gillespie
H. Sawyer Gillespie
CLCharles C. H. Lin
Charles C. H. Lin
JPJordan M Prutkin
Jordan M Prutkin