Susana Lage Cal

Dr. Susana Lage Cal

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Energy Reports
Verified
Journal Article
Open access
SCSusana Lage Cal
Susana Lage Cal
MFM.B. Folgueras-Díaz
M.B. Folgueras-Díaz
MAM. Alonso-Hidalgo
M. Alonso-Hidalgo
DAVID GARCIADAVID GARCIA
DAVID GARCIA
FFF.J. Fernández-García
F.J. Fernández-García

1 February 2020 in Energy Reports
Verified
Journal Article
Open access
LSL. Sanz-Prada
L. Sanz-Prada
MFM.B. Folgueras-Díaz
M.B. Folgueras-Díaz
MAM. Alonso-Hidalgo
M. Alonso-Hidalgo
SCSusana Lage Cal
Susana Lage Cal

6 November 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
MFM. Belén Folgueras
M. Belén Folgueras
MAManuela Alonso
Manuela Alonso
JFJuan R. Folgueras
Juan R. Folgueras
SCSusana Lage Cal
Susana Lage Cal
In this work, data about REY concentrations in sewage sludges and their ashes have been analysed. The source of REY in them is mainly geogenic, which is why sludges from regions like China and Brazil have higher concentrations. Thus, the combustion or co-combustion of sewage sludge as a way of recovery its energy potential and, secondarily, the processing of their ashes in order to obtain REY may be interesting, in certain regions, depending on the techno-economic and environmental context of the moment.

29 November 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
SCSusana Lage Cal
Susana Lage Cal
MFM. Belén Folgueras
M. Belén Folgueras
JLJuan Carlos Luengo-García
Juan Carlos Luengo-García
Attached sunspaces are widely employed in the higher floors of traditional residences in the North of Spain. More specifically, in Asturias, it is easy to find them south-oriented and cantilever-positioned. This helps to take the greatest advantage of sun rays, especially during long winter months, and provides a ground-leveled, rain-protected, arcaded space. The function of such space is being a passing area (if it is to be found in a city house), or an exterior mudroom (if it is to be found in a country estate). With respect to the thermal impact of attached sunspaces in inner comfort condition, it is worth determining whether they are truly valuable elements, suitable to be employed in contemporary passive residences in the Atlantic area, or if their climate-dependant performance invalidates such use.

29 November 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
SCSusana Lage Cal
Susana Lage Cal
MFM. Belén Folgueras
M. Belén Folgueras
JLJuan Carlos Luengo-García
Juan Carlos Luengo-García
Thermal and hygric inertia are determining factors when studying residences habitability, most particularly when no HVAC systems are available. Since the Asturian house under consideration is a listed building that, due to its protection grade, cannot be artificially air-conditioned, such is precisely the case. When it was built, living spaces were limited to the ground floor (where social and working activities were to take place) and the first floor (where private family rooms were set). By contrast, the attic was the house store and both the entrance and the stairs were (and still are) passing areas. The results of the field study confirm the adequacy of inner spaces to the purpose they were meant for.

4 March 2024
Verified
Conference Paper
Open access
PDF file
SCSusana Lage Cal
Susana Lage Cal
FBFolgueras Díaz María Belén
Folgueras Díaz María Belén
AMAlonso Hidalgo Manuela
Alonso Hidalgo Manuela
LCLuengo García Juan Carlos
Luengo García Juan Carlos
El sector residencial es responsable, en España, del 17% del consumo final de energía y del 25% de la demanda de energía eléctrica [1]. Además, en todas las áreas geográficas del país, la calefacción es el elemento más exigente, llegando a representar el 47% del consumo energético de una vivienda estándar [2].En semejante contexto, resulta fundamental definir las condiciones de confort térmico suficientes para asegurar la habitabilidad de los edificios de uso residencial y trabajar en su obtención, a partir de la fase de diseño. En el caso que nos ocupa, el objetivo pasa por evaluar la contribución al comportamiento térmico de un inmueble de unos elementos que se encuentran en muchas casas tradicionales asturianas: las galerías. Para ello, se eligió una vivienda unifamiliar de tres plantas, situada en Avilés (Asturias) y se siguió una metodología de estudio de caso. Haciendo uso del programa TRNSYS 17, se modelizó el comportamiento térmico del interior de una de las galerías de la mencionada residencia, durante un periodo de 12 h. De este modo fue posible obtener datos de la evolución de la temperatura del aire en dicho espacio, que se validaron comparándolos con registros experimentales correspondientes al mismo intervalo de tiempo. Finalmente, se llevaron a cabo nuevas modelizaciones de la conducta térmica del espacio estudiado, tanto sin ninguna galería, como con la galería dispuesta según una orientación menos favorable. En ambos casos fue posible concluir que,