Olena Yatsenko

Dr. Olena Yatsenko

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Journal of Building Engineering
Verified
Journal Article
Closed access
VDValerii Deshko
Valerii Deshko
IBInna Bilous
Inna Bilous
ISIryna Sukhodub
Iryna Sukhodub
OYOlena Yatsenko
Olena Yatsenko

1 January 2021 in Rocznik Ochrona Środowiska
Verified
Journal Article
Closed access
VDValerii Deshko
Valerii Deshko
IBInna Bilous
Inna Bilous
DBDmytro Biriukov
Dmytro Biriukov
OYOlena Yatsenko
Olena Yatsenko
Transient Energy Models of Housing Facilities Operation

20 September 2021 in POWER ENGINEERING: economics, technique, ecology
Verified
Journal Article
Open access
PDF file
VDValerii Deshko
Valerii Deshko
IBInna Bilous
Inna Bilous
ISI. Sukhodub
I. Sukhodub
OYOlena Yatsenko
Olena Yatsenko
Modern results of Ukrainian buildings energy analysis show that 30-50% of the energy for heating goes to heat the supply air, and that is the largest share in the building energy balance. In terms of energy consumption, efficiency of the air exchange mode largely depends on occupancy schedule and air distribution in time and space. The application of air exchange schedule approach makes more sense in case when individual heating control is carried out. Therefore, during occupied hours, the comfortable ventilation level can be ensured, and, during unoccupied hours, it can be reduced to a minimum. According to the results of the study, the use of intermittent air exchange mode in the studied apartment on weekdays, leads to decrease in energy consumption compared to constant air exchange at the level of upper values of the ventilation schedule. In terms of energy efficiency, the use of the constant air change rate from ASHRAE Std 62 is the most efficient approach. In terms of indoor air quality and concentration of CO2 and VOCs, the scheduled air exchange approach with increased air change rates (from EN 16798) during occupied hours is more efficient. Therefore, the use of required and experimental air change rate values to create the hourly schedules allows to define more precisely a building energy consumption and to choose an optimal operation schedule for building engineering systems to provide thermal comfort and indoor air quality during occupied hours.

17 March 2025 in POWER ENGINEERING: economics, technique, ecology
Verified
Journal Article
Open access
PDF file
MSMaryna Shovkaliuk
Maryna Shovkaliuk
YRYevhenii Rabenko
Yevhenii Rabenko
OYOlena Yatsenko
Olena Yatsenko
Increasing the energy efficiency of the building stock is a strategic task for Ukraine, and to attract funding for comprehensive thermal modernization projects, it is necessary to conduct an energy audit and draw up an energy certificate for residential and multi-apartment buildings. Energy auditors in Ukraine usually develop their own models for calculations, but there are software products that allow modeling the energy consumption of buildings taking into account the features of operation, characteristics of enclosures and engineering systems. Studying their capabilities and comparative analysis is a relevant task. The use of software products by energy auditors helps automate energy consumption calculations before and after the implementation of energy saving measures, develop an energy certificate, and accelerate the implementation of complex thermal modernization projects. The purpose of the work is to review the capabilities of software products for calculating specific energy consumption for various needs and energy efficiency classes, as well as developing an energy certificate with a comparative analysis using the example of a residential multi-apartment building. Research methods: analytical methods, comparative and structural analysis method, feasibility studies using E-Audit, Audytor OZC, MS Excel, etc. In accordance with the purpose of the work, the following tasks were set: - to study the capabilities of software products for modeling energy characteristics; - to conduct an energy survey of the building; - to develop a mathematical model for calculating specific energy consumption and energy efficiency class according to the national calculation methodology; - to calculate energy consumption using specialized software products with the development of an energy certificate; - to justify measures to increase energy efficiency for the building with the determination of energy and economic effects.

13 October 2026 in Eng
Verified
Journal Article
Open access
PDF file
VDValerii Deshko
Valerii Deshko
MPMYKOLA Politykin
MYKOLA Politykin
OYOlena Yatsenko
Olena Yatsenko
KLKristina Lebedeva
Kristina Lebedeva
The increasing deployment of rooftop photovoltaic (PV) systems in multi-apartment buildings offers opportunities to improve energy resilience and reduce dependence on grid electricity, yet their real-world performance remains insufficiently documented. This study evaluates a rooftop PV system (32.3 kWp, 76 modules) with 92.16 kWh of lithium iron phosphate storage supplying the shared and critical infrastructure of a 16-story apartment building in Kyiv, Ukraine. Eleven months of metered operation, from October 2025 to August 2026, are compared month by month with a three-dimensional PV*SOL model of the same array. In the warm half of the year, the metered generation agrees with the simulation within −8.5%, which confirms the model inputs. From October to February, it falls to 43% of the simulated values, although measurements on clear days at the end of February show a peak output of about 15 kW, the same level as on clear summer days, so that the deviation is associated with the weather of the monitored season rather than with the configuration of the installation. Over the monitored period the plant generated 19.0 MWh, of which 34% was exported to the grid, and covered 38 to 48% of the 26.4 MWh demand of the monitored loads, compared with 27.5% obtained from a simulation without storage. The measured operation also documents a daily control strategy in which the battery is charged from the PV array during the day, discharged into the grid during the evening peak, and switched to a reserve mode with a minimum state of charge of 50 to 60% as soon as scheduled outages resume, which provides an explicit trade-off between revenue and resilience. The results show that the realized output of rooftop PV in such buildings is governed by the operating strategy and by the actual weather rather than by the rated capacity of the array alone.