Manihars Situmorang

Prof. Dr. Manihars Situmorang


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 1998 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MSManihars Situmorang
Manihars Situmorang
J. GoodingJ. Gooding
J. Gooding
DHD.BRynn Hibbert
D.BRynn Hibbert
DBDonald Barnett
Donald Barnett

1 January 1999 in The Analyst
Verified
Journal Article
Closed access
PDF file
MSManihars Situmorang
Manihars Situmorang
DHD. Brynn Hibbert
D. Brynn Hibbert
J. GoodingJ. Gooding
J. Gooding
DBDonald Barnett
Donald Barnett
The development of a sulfite biosensor based on the immobilization of sulfite oxidase (SOD) in electrodeposited polytyramine is described. Electropolymerization of polytyramine and simultaneous immobilization of SOD on platinized glassy carbon (GC/Pt) were performed in an aqueous solution of 0.1 M tyramine containing SOD. The sulfite biosensor constructed with five voltammetric sweep cycles showed a sensitive response to sulfite with a linear calibration curve in the concentration range 0.002–0.3 mM sulfite, slope 2.70 µA l mmol–1, and detection limit 0.001 mM sulfite (S/N = 3). Deposited polytyramine enhanced the selectivity of the biosensor by eliminating direct oxidation of sulfite and other interfering agents at the electrode. The biosensor was applied for the determination of sulfite in various types of wine samples, and the results obtained are in agreement with those using an AOAC method.

11 January 2001 in Analytical Sciences
Verified
Journal Article
Closed access
J. GoodingJ. Gooding
J. Gooding
PEPaul Erokhin
Paul Erokhin
Dusan LosicDusan Losic
Dusan Losic
WYWenrong Yang
Wenrong Yang
VPVanessa Policarpio
Vanessa Policarpio
JSJoe Shapter
Joe Shapter
The fabrication of enzyme electrodes using self-assembled monolayers (SAMs) has attracted considerable interest because of the spatial control over the enzyme immobilization. A model system of glucose oxidase covalently bound to a gold electrode modified with a SAM of 3-mercaptopropionic acid was investigated with regard to the effect of fabrication variables such as the surface topography of the underlying gold electrode, the conditions during covalent attachment of the enzyme and the buffer used. The resultant monolayer enzyme electrodes have excellent sensitivity and dynamic range which can easily be adjusted by controlling the amount of enzyme immobilized. The major drawback of such electrodes is the response which is limited by the kinetics of the enzyme rather than mass transport of substrates. Approaches to bringing such enzyme electrodes into the mass transport limiting regime by exploiting direct electron transfer between the enzyme and the electrode are outlined.

1 August 1999 in Analytica Chimica Acta
Verified
Journal Article
Closed access
MSManihars Situmorang
Manihars Situmorang
J. GoodingJ. Gooding
J. Gooding
DHD.Brynn Hibbert
D.Brynn Hibbert

1 January 1999 in Analytical Communications
Verified
Journal Article
Closed access
PDF file
J. GoodingJ. Gooding
J. Gooding
MSManihars Situmorang
Manihars Situmorang
PEPaul Erokhin
Paul Erokhin
DHD. Brynn Hibbert
D. Brynn Hibbert
This paper presents a simple assay for the estimation of the amount of glucose oxidase immobilised onto the surface of enzyme electrodes. The two flavin adenine dinucleotide (FAD) cofactors were stripped from immobilised glucose oxidase using an 8 M urea solution. The resultant concentration of FAD in the urea solution was quantified using either fluorescence or voltammetry to determine the amount of glucose oxidase on the electrode surface. The assay is applied to a variety of different enzyme electrodes and is verified for a monolayer enzyme electrode using a quartz crystal microbalance.

24 September 2015 in International Education Studies
Verified
Journal Article
Open access
PDF file
MSManihars Situmorang
Manihars Situmorang
MSMarham Sitorus
Marham Sitorus
WHWesly Hutabarat
Wesly Hutabarat
ZSZakarias Situmorang
Zakarias Situmorang
The development of innovative chemistry learning material for bilingual Senior High School (SHS) students in Indonesia is explained. The study is aimed to obtain an innovative chemistry learning material based on national curriculum in Indonesia to be used as a learning media in the teaching and learning activities. The learning material is developed by enhancing the chemistry topics to meet the requirement of a national curriculum followed by integration of laboratory experiments, learning media, and contextual application of the relevant chemistry topics. The material is then designed in printed and electronic bases. The performance of developed chemistry material is standardized to meet good quality learning material for class purposes. The results showed that the performance of developed chemistry materials is categorized as very good. The developed learning material is found effective to be used in teaching and learning process, and be able to motivate the students to learn chemistry. The facilities provided in the material are adequate to guide the student to study chemistry independently that make learning activities moving from teacher centre learning become students centre learning. Students achievements in experimental class (M = 83.0) is found higher than that with control class (M = 73.5), where both are significantly different. There is a positive correlation between the student’s motivations with the student’s achievement in chemistry subject, where the correlation in experimental class (R² = 0.711) is better than in control class (R² = 0.467).