Andrew Li

Dr. Andrew Li


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2026 in Medicina
Verified
Journal Article
Open access
PDF file
OSOlivia Schaffer
Olivia Schaffer
MKMitchell Francis Kennedy
Mitchell Francis Kennedy
ALAndrew Li
Andrew Li
DNDavid Novikov
David Novikov
MMMorteza Meftah
Morteza Meftah
RSRan Schwarzkopf
Ran Schwarzkopf
Background and Objectives: Cementless total knee arthroplasty (TKA) has gained popularity but comparative outcome data across implant systems remain limited. This study compared survivorship and clinical outcomes of two cementless cruciate-retaining TKA implants from different manufacturers. Materials and Methods: We performed a retrospective, single-institution review of 220 patients who had a cementless cruciate-retaining TKA implant between 2019 and 2024; 110 patients received Implant A and 110 patients received Implant B. Baseline variables included demographics, comorbidities, and preoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR). Clinical outcomes included 90-day readmission, all-time revision, reoperation, manipulation under anesthesia, and postoperative KOOS, JR scores. Propensity score-based overlap weighting was used to create a balanced pseudo-population for adjusted analyses. Adjusted outcomes included weighted logistic regression for two-year revision and a weighted Cox proportional hazards model for time to revision. Results: Crude revision rates were low and not significantly different (A: 0.9 versus B: 2.7%, p = 0.622). Overlap weighting achieved balance across all measured baseline covariates. Unadjusted rates of 90-day readmission, reoperation, and manipulation under anesthesia were similar between groups. In adjusted analyses, no statistically significant difference was observed for two-year revision in Implant B vs. A cohorts (OR 2.17, 95% CI 0.10 to 157, p = 0.621) or time to revision (HR 2.22, 95% CI 0.18 to 27.09, p = 0.533). Conclusions: Both cementless cruciate-retaining TKA systems demonstrated low early revision rates in this cohort. Propensity score-adjusted analyses reduced measured baseline imbalances and did not identify a significant difference in revision risk between implants; however, interpretation is limited by sparse revision events, potential residual confounding, and the retrospective observational design.