NAZİFE NUR AKBULUT

Dr. NAZİFE NUR AKBULUT

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Clinical and Experimental Otorhinolaryngology
Verified
Journal Article
Open access
PDF file
EDEmine Demir
Emine Demir
NANAZİFE NUR AKBULUT
NAZİFE NUR AKBULUT
MÇMetin Çeliker
Metin Çeliker
FÇFatma Beyazal Çeliker
Fatma Beyazal Çeliker
MİMehmet Fatih İNECİKLİ
Mehmet Fatih İNECİKLİ
EDEngin DURSUN
Engin DURSUN
We explored whether wideband tympanometry (WBT) could be used as a screening test for superior semicircular canal dehiscence (SSCD), and obtained new WBT data (given that the test is not yet in common clinical use) on patients with SSCD. We compared the WBT data of patients clinically and radiologically diagnosed with SSCD in our hospital between 2013 and 2018 to those of healthy volunteers. We compared the resonance frequency (RF), maximum absorbance frequency (MAF), and maximum absorbance ratio (MAR). The t-test was used for statistical analysis with the significance level set to P<0.05. In addition, we used receiver operating characteristic analysis to derive cutoff values for SSCD diagnosis in terms of sensitivity and specificity. Seventeen patients (four with bilateral and 13 with unilateral disease; 17 ears) diagnosed with SSCD and 27 healthy volunteers (47 ears) were included. The mean RFs of the SSCD patients and healthy subjects were 548.7 Hz (range, 243 to 853 Hz) and 935.1 Hz (range, 239 to 1,875 Hz), respectively (P<0.001). The mean MARs of the SSCD patients and healthy subjects were 89.4% (range, 62% to 100%) and 82.4% (range, 63% to 99%), respectively (P=0.005). The mean MAFs of the SSCD patients and healthy subjects were 1,706.3 Hz (range, 613 to 3,816 Hz) and 2,668 Hz (range, 876 to 4,387 Hz), respectively (P<0.001). In terms of SSCD diagnosis, a MAR above 86% afforded 81% sensitivity and 77% specificity; an RF below 728 Hz, 86% sensitivity and 81% specificity; and an MAF below 1,835 Hz, 79% sensitivity and 67% specificity. WBT may be a useful clinical screening test for SSCD. The RF and MAF were lower, and the MAR higher, in SSCD patients than in normal controls.

25 July 2022 in Clinical Otolaryngology
Verified
Journal Article
Closed access
NANAZİFE NUR AKBULUT
NAZİFE NUR AKBULUT
ZCZerrin Özergin Coşkun
Zerrin Özergin Coşkun
MÇMetin Çeliker
Metin Çeliker
ÖEÖzlem Çelebi Erdivanlı
Özlem Çelebi Erdivanlı
STSuat Terzi
Suat Terzi
EDEngin Dursun
Engin Dursun