Hui-Ju Tien

Dr. Hui-Ju Tien

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2020 in British Journal of Radiology
Verified
Journal Article
Open access
HYHsin-Pei Yeh
Hsin-Pei Yeh
YHYu-Chuen Huang
Yu-Chuen Huang
LWLi-Ying Wang
Li-Ying Wang
PSPei-Wei Shueng
Pei-Wei Shueng
HTHui-Ju Tien
Hui-Ju Tien
CHCHEN-HSI HSIEH
CHEN-HSI HSIEH
Objectives: To evaluate the feasibility and optimal restricted angle of the complete-directional-complete block (CDCB) technique in helical tomotherapy (HT) by including regional nodal irradiation (RNI) with the internal mammary node (IMN) in left-sided breast cancer. Methods: Ten left-sided breast cancer patients treated with 50 Gy in 25 fractions were compared with five-field intensity-modulated radiation therapy (5F-IMRT) and six types of HT plans. In the HT plans, complete block (CB), organ-based directional block (OBDB) and CDCB with different restricted angles were used. Results: The conformity index (CI) between the CDCB0,10,15,20 and 5F-IMRT groups was similar. Compared to CB, OBDB and 5F-IMRT, CDCB20 resulted in a decreased ipsilateral mean lung dose. The low-dose region (V5) of the ipsilateral lung in OBDB (84.0%) was the highest among all techniques (p < 0.001). The mean dose of the heart in CB was significantly reduced (by 11.5–22.4%) compared with other techniques. The V30 of the heart in CDCB20 (1.9%) was significantly lower than that of CB, OBDB and 5F-IMRT. Compared to the mean dose of the left anterior descending (LAD) artery of 5F-IMRT (27.0 Gy), CDCB0, CDCB10, CDCB15, CDCB20 and OBDB reduced the mean dose effectively by 31.7%, 38.3%, 39.6%, 42.0 and 56.2%, respectively. Considering the parameters of the organs-at-risk (OARs), CDCB10,15,20 had higher expectative values than the other techniques (p = 0.01). Conclusions: HT with the CDCB technique is feasible for treating left-sided breast cancer patients. The CDCB10-20 techniques not only achieved similar planning target volume coverage, homogeneity and dose conformity but also allowed better sparing of the heart and bilateral lungs. Advances in knowledge: For left-sided breast cancer patients whose RNI field includes the IMN, heart avoidance is an important issue. The CDCB technique achieved good PTV coverage, homogeneity and dose conformity and allowed better sparing of the mean dose of the lung, the LAD artery, and the heart and reduced the V30 of the heart.

13 July 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
ASAn-Cheng Shiau
An-Cheng Shiau
CHChen-Hsi Hsieh
Chen-Hsi Hsieh
HTHui-Ju Tien
Hui-Ju Tien
HYHsin-Pei Yeh
Hsin-Pei Yeh
CLChi-Ta Lin
Chi-Ta Lin
LWLe-Jung Wu
Le-Jung Wu
Purpose. Limited-tomotherapy and hybrid-IMRT treatment techniques were compared for reductions in ipsilateral and contralateral lung, heart, and contralateral breast radiation doses.Methods and Materials.Thirty consecutively treated left-sided early-stage breast cancer patients were scheduled for lTomo and hIMRT. For the hIMRT plan conventional tangential-field and four-field IMRT plans were combined with different weightings in the prescribed dose. For the lTomo plan a geometrically limited arc was designed for the beamlet entrance. ADpof 50.4 Gy in 28 fractions was used for the PTV. The dose coverage, homogeneity index, conformity index of the target, and the dose volumes of critical structures were compared.Results.Both modalities presented similar target coverage. The homogeneity and conformity were improved for lTomo withP<0.001andP=0.006, respectively. In the lTomo plan a concave dose distribution was generated with significant dose reductions in both high and low dose regions for ipsilateral lung and heart (P<0.001).Conclusions. lTomo plan can have similar dose coverage and better homogeneity and conformity to the target. By properly designing the directionally and completely blocked structure, lTomo plan was developed successfully in reducing doses to the healthy tissues for early-stage left-sided breast cancer radiotherapy.

26 September 2013 in Journal of Translational Medicine
Verified
Journal Article
Open access
PDF file
CHChen-Hsi Hsieh
Chen-Hsi Hsieh
MHMei-Ling Hou
Mei-Ling Hou
MCMeng-Hsuan Chiang
Meng-Hsuan Chiang
HTHung-Chi Tai
Hung-Chi Tai
HTHui-Ju Tien
Hui-Ju Tien
Yu-Jen ChenYu-Jen Chen
Yu-Jen Chen
Background: 5-fluorouracil (5-FU) and cisplatin (CDDP) are used to enhance radiotherapy (RT) effect for head and neck (HN) cancers. However, the effect of local RT on systemic chemotherapeutics remains unclear. Here, we evaluated the influence of HN irradiation on the pharmacokinetics (PK) of 5-FU and CDDP in rats as experimental model. Methods: The radiation dose distributions of HN cancer patients were determined for the low dose areas, which are generously deposited around the target volume. Two Gy and 0.5 Gy RT were selected. Single-fraction radiation was delivered to the HN of Sprague–Dawley rats. 5-FU at 100 mg/kg or CDDP at 5 mg/kg was intravenously infused 24 hours after radiation. Results: Radiation at 2 Gy reduced the area under the plasma concentration vs. time curve (AUC) of 5-FU and CDDP by 16% and 29% compared to non-irradiated controls, respectively. This was accompanied by incremental total plasma clearance values. Intriguingly, low dose radiation at 0.5 Gy resulted in a similar pharmacokinetic profile, with a 17% and 33% reduction in the AUC of 5-FU and CDDP, respectively. The changes in AUC of bile, which increases with RT, were opposite to AUC of plasma for both drugs. Conclusions: The local HN RT could modulate systemic PK of 5-FU and CDDP in rats. This unexpected RT-PK phenomena may provide a reference for adjustment of drug administration and is worthy of further investigation. Trial registration: ClinicalTrials.gov ID NCT01755585 and NCT01609114

23 February 2016 in BMC Cancer
Verified
Journal Article
Open access
PDF file
CHCHEN-HSI HSIEH
CHEN-HSI HSIEH
PSPei-Wei Shueng
Pei-Wei Shueng
LWLi-Ying Wang
Li-Ying Wang
YHYu-Chuen Huang
Yu-Chuen Huang
LLLi-Jen Liao
Li-Jen Liao
HTHui-Ju Tien
Hui-Ju Tien
We compared the outcome of patients who received non-image-guided intensity-modulated radiotherapy (IMRT) with those who received helical tomotherapy (HT), a daily image-guided radiotherapy (IGRT), after surgery for oral cavity cancer (OCC). During the period November 2006 to December 2013, a total of 152 postoperative OCC patients underwent either IMRT (n = 79) or daily IGRT (n = 73) 4 to 6 weeks after surgery. Patients in the IMRT group received 6 MV photon beams to 7 fields and those in the IGRT group received daily fractions of 1.8 or 2 Gy on five consecutive days. Patients who received daily IGRT had higher 5-year overall survival than those who received IMRT (87 % versus 48 %, p = 0.015). The local progression-free survival rate was also higher in patients who received IGRT (85 % versus 58 %, p = 0.006). More patients in the IGRT group completed the package of overall treatment time in ≤ 13 weeks and completed their course of radiation therapy in ≤ 8 weeks than patients in the IMRT group (89 % versus 68 %, p = 0.002; 84 % versus 58 %, p = 0.001), respectively. The rate of local failure in the primary tumor area was 24.0 % in the IMRT group and 6.8 % in the IGRT group. Among patients with primary local failure, the marginal failure rate was 52.6 % in the IMRT group and 0 % in the IGRT group. For patients with locally advanced OCC, postoperative IGRT results in better overall survival, better local progression-free survival, less marginal failure and shorter overall treatment time than postoperative non-image-guided IMRT.

12 February 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
CCChiu-Han Chang
Chiu-Han Chang
GMGreta S. P. Mok
Greta S. P. Mok
PSPei-Wei Shueng
Pei-Wei Shueng
HYHsin-Pei Yeh
Hsin-Pei Yeh
ASAn-Cheng Shiau
An-Cheng Shiau
TWTung-Hsin Wu
Tung-Hsin Wu
Radiation pneumonitis (RP) is a common complication for radiotherapy of esophageal cancer and is associated with the low dose irradiated lung volume. This study aims to reduce the mean lung dose (MLD) and the relative lung volume at 20 Gy (V20) and at low dose region using various designs of the fan-shaped complete block (FSCB) in helical tomotherapy. Hypothetical esophageal tumor was delineated on an anthropomorphic phantom. The FSCB was defined as the fan-shaped radiation restricted area located in both lungs. Seven treatment plans were performed with nonblock design and FSCB with different fan angles, that is, from 90° to 140°, with increment of 10°. The homogeneous index, conformation number, MLD, and the relative lung volume receiving more than 5, 10, 15, and 20 Gy (V5,V10,V15, andV20) were determined for each treatment scheme. There was a substantial reduction in the MLD,V5,V10,V15, andV20when using different types of FSCB as compared to the nonblock design. The reduction ofV20,V15,V10, andV5was 6.3%–8.6%, 16%–23%, 42%–57%, and 42%–66% for FSCB 90°–140°, respectively. The use of FSCB in helical tomotherapy is a promising method to reduce the MLD,V20, and relative lung volume in low dose region, especially inV5andV10for esophageal cancer.

28 January 2019 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
CHCHEN-HSI HSIEH
CHEN-HSI HSIEH
HTHui-Ju Tien
Hui-Ju Tien
YYYuan-Bin Yu
Yuan-Bin Yu
YWyuanhung wu
yuanhung wu
PSPei-Wei Shueng
Pei-Wei Shueng
LWLi-Ying Wang
Li-Ying Wang
Helical irradiation of the total skin (HITS) was modified as simultaneous integrated boost (SIB)-helical arc radiotherapy of total skin (HEARTS) technique and applied to an acute myeloid leukemia (AML) patient with disseminated leukemia cutis. The original HITS plan was revised for different regimens, i.e. HEARTS, low-dose HEARTS and SIB-HEARTS. The uniformity index (UI), conformity index (CI), and dose of organs at risk (OARs) were used to evaluate the plans. Additionally, the SIB-HEART (21/15 Gy) was delivered to the total skin and chloromas. No significant differences were observed for the CI and UI between HITS and HEARTS regimens. Compared with HITS, the reduced mean doses to various bone marrows ranged from 17 to 88%. The mean OARs doses for the head, chest and abdomen of a patient with AML treated with SIB-HEARTS (21/15 Gy) were 2.1 to 21.9 Gy, 1.8 to 7.8 Gy and 1.7 to 3.3 Gy, respectively. No severe adverse effects were noted except for grade 4 leukocytopenia and thrombocytopenia. HEARTS and different regimens reduced the dose to OARs and bone marrow while maintaining the uniformity and conformity. SIB-HEARTS deliveries different doses to the total skin and enlarged tumors simultaneously. Retrospectively registered and approved by the Institutional Review Board of our hospital ( FEMH-106151-C ).