Kazunori Takada

Dr. Kazunori Takada


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2024 in Endoscopy
Verified
Journal Article
Closed access
PDF file
KTKazunori Takada
Kazunori Takada
Naohisa YoshidaNaohisa Yoshida
Naohisa Yoshida
YHYoshikazu Hayashi
Yoshikazu Hayashi
DTDaichi Togo
Daichi Togo
SOShiro Oka
Shiro Oka
OGon behalf of the ABCD-J Working Group
on behalf of the ABCD-J Working Group
Background The effectiveness of prophylactic clip closure in reducing the risk of delayed bleeding after colorectal endoscopic submucosal dissection (ESD) is uncertain among patients on anticoagulants. We therefore aimed to assess this effectiveness using data from a large multicenter study. Methods We used the ABCD-J study database to analyze delayed bleeding among 34 455 colorectal ESD cases from 47 Japanese institutions. Delayed bleeding rates among the no/partial and complete closure groups were compared in patients on direct oral anticoagulants (DOACs) or warfarin. Propensity score matching was used for baseline characteristics to reduce the effects of selection bias. Results Overall, data from 1478 patients on anticoagulants who underwent colorectal ESD were examined. After propensity score matching, the complete and no/partial closure groups were compared in 212 patients on DOACs and 82 on warfarin. The complete closure group showed a significantly lower delayed bleeding rate in patients receiving DOACs (10.8 % vs. 5.2 %, absolute risk reduction [ARR] 5.7 %, P = 0.048) and warfarin (17.1 % vs. 6.1 %, ARR 11.0 %, P = 0.049). Additionally, complete closure significantly reduced the risk of delayed bleeding among patients taking DOACs for right-sided lesions (ARR 6.7 %, P = 0.04), whereas no risk reduction was observed for left-sided (P > 0.99) or rectal (P = 0.50) lesions. A similar trend was observed among patients on warfarin. Conclusions Prophylactic complete clip closure after colorectal ESD significantly reduced the delayed bleeding rate in patients receiving DOACs or warfarin. It should be performed after ESD, particularly for right-sided lesions.

5 July 2022 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
KTKazunori Takada
Kazunori Takada
KHKinichi Hotta
Kinichi Hotta
KIKenichiro Imai
Kenichiro Imai
SISayo Ito
Sayo Ito
YKYoshihiro Kishida
Yoshihiro Kishida
HOHiroyuki Ono
Hiroyuki Ono

26 July 2023 in Journal of Gastroenterology and Hepatology
Verified
Journal Article
Closed access
KIKazuma Ishikawa
Kazuma Ishikawa
HIHirotoshi Ishiwatari
Hirotoshi Ishiwatari
KSKeiko Sasaki
Keiko Sasaki
FNFumitaka Niiya
Fumitaka Niiya
TSTatsunori Satoh
Tatsunori Satoh
HOHiroyuki Ono
Hiroyuki Ono

5 May 2022 in Journal of Gastroenterology and Hepatology
Verified
Journal Article
Closed access
KHKinichi Hotta
Kinichi Hotta
SOShozo Osera
Shozo Osera
KSKei Shinoki
Kei Shinoki
KIKenichiro Imai
Kenichiro Imai
SISayo Ito
Sayo Ito
HOHiroyuki Ono
Hiroyuki Ono

25 January 2024 in Journal of Gastroenterology and Hepatology
Verified
Journal Article
Closed access
TOTaishi Okumura
Taishi Okumura
KIKenichiro Imai
Kenichiro Imai
MMMasashi Misawa
Masashi Misawa
SKShin‐Ei Kudo
Shin‐Ei Kudo
KHKinichi Hotta
Kinichi Hotta
HOHiroyuki Ono
Hiroyuki Ono

29 May 2024 in DEN Open
Verified
Journal Article
Open access
TOTaishi Okumura
Taishi Okumura
KHKinichi Hotta
Kinichi Hotta
KIKenichiro Imai
Kenichiro Imai
SISayo Ito
Sayo Ito
YKYoshihiro Kishida
Yoshihiro Kishida
HOHiroyuki Ono
Hiroyuki Ono
Objective: A newly launched endoscopy system (EVIS X1, CV‐1500; Olympus) is equipped with texture and color enhancement imaging (TXI). We aimed to investigate the efficacy of TXI for the visibility and diagnostic accuracy of non‐polypoid colorectal lesions.Methods: We examined 100 non‐polypoid lesions in 42 patients from the same position, angle, and distance of the view in three modes: white light imaging (WLI), narrow‐band imaging (NBI), and TXI. The primary outcome was to compare polyp visibility in the three modes using subjective polyp visibility score and objective color difference values. The secondary outcome was to compare the diagnostic accuracy without magnification.Results: Overall, the visibility score of TXI was significantly higher than that of WLI (3.7 ± 1.1 vs. 3.6 ± 1.1; p = 0.008) and lower than that of NBI (3.7 ± 1.1 vs. 3.8 ± 1.1; p = 0.013). Color difference values of TXI were higher than those of WLI (11.5 ± 6.9 vs. 9.1 ± 5.4; p < 0.001) and lower than those of NBI (11.5 ± 6.9 vs. 13.1 ± 7.7; p = 0.002). No significant differences in TXI and NBI (visibility score: 3.7 ± 1.0 vs. 3.8 ± 1.1; p = 0.833, color difference values: 11.6 ± 7.1 vs. 12.9 ± 8.3; p = 0.099) were observed for neoplastic lesions. Moreover, the diagnostic accuracy of TXI was significantly higher than that of NBI (65.5% vs. 57.6%, p = 0.012) for neoplastic lesions.Conclusions: TXI demonstrated higher visibility than that of WLI and lower than that of NBI. Further investigations are warranted to validate the performance of the TXI mode comprehensively.