Shreyaa Rohindra Lall

Dr. Shreyaa Rohindra Lall

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2026 in American Journal of Ophthalmology
Verified
Journal Article
Open access
SLShreyaa Rohindra Lall
Shreyaa Rohindra Lall
NSNiroj Kumar Sahoo
Niroj Kumar Sahoo
NHNasiq Hasan
Nasiq Hasan
SSSumit Randhir Singh
Sumit Randhir Singh
AZArman Zarnegar
Arman Zarnegar
Jay ChhablaniJay Chhablani
Jay Chhablani

27 July 2026 in Retina
Verified
Journal Article
Closed access
SLShreyaa Rohindra Lall
Shreyaa Rohindra Lall
NSNiroj Kumar Sahoo
Niroj Kumar Sahoo
NHNasiq Hasan
Nasiq Hasan
AZArman Zarnegar
Arman Zarnegar
PGPriyanka Gandhi
Priyanka Gandhi
Jay ChhablaniJay Chhablani
Jay Chhablani
Purpose: To compare baseline characteristics and clinical course between Hispanic and non-Hispanic patients with Central Serous Chorioretinopathy (CSC). Methods: This retrospective, multicentre study from the Macula Society CSC Research Network (MICRoN) included Hispanic and non-Hispanic patients with CSC. Demographic characteristics and multimodal imaging variables were compared between groups. Regression analyses identified factors associated with visual outcomes, structural changes, and disease recurrence/persistence. Results: A total of 480 patients were included (130 Hispanic, 350 non-Hispanic). Non-Hispanic patients were significantly older at presentation (48.8±11.1 vs 45.3±11.6 years, p=0.003) and had better baseline best recorded visual acuity (BRVA; 20/25 vs 20/40, p<0.001). A significantly higher percentage of Hispanic patients presented with complex CSC (73.8% vs 28.3%, p<0.001), multifocal RPE alterations (58.5% vs 9.7%, p<0.001), and greater neurosensory detachment height (NSD; 193 [IQR 100–301] vs 113 [IQR 66–193] microns, p<0.001). Conversely, non-Hispanic patients demonstrated larger areas of RPE alteration (1.5 [IQR 1–3] vs 1 [IQR 0.25–1.5] disc areas, p<0.001). At last follow-up, both groups showed significant improvement in BRVA (Hispanics: 20/40 to 20/25, p<0.001; non-Hispanics: 20/25 to 20/20, p<0.001), with no significant difference in rates of recurrence (40% vs 35.7%, p=0.08) or persistence (11.5% vs 13.1%, p=0.08). Conclusion: In our cohort, Hispanic patients more commonly presented with complex CSC, multifocal RPE alterations, and greater NSD height, while non-Hispanic patients were older with better baseline vision and larger areas of RPE alteration. Despite these differences, visual outcomes improved meaningfully in both groups, with comparable rates of recurrence and persistence.

26 October 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
NHNasiq Hasan
Nasiq Hasan
AGAdarsh Gadari
Adarsh Gadari
SVSharat Chandra Vupparaboina
Sharat Chandra Vupparaboina
SLShreyaa Rohindra Lall
Shreyaa Rohindra Lall
MEMaria Emfietzoglou
Maria Emfietzoglou
Jay ChhablaniJay Chhablani
Jay Chhablani
Objectives: To validate a deep learning-based algorithm for automated detection, segmentation, and quantitative assessment of retinal fluid on optical coherence tomography (OCT) across multiple retinal diseases. Methods: In this retrospective validation study, spectral-domain OCT volume scans from eyes with neovascular age-related macular degeneration (nAMD), diabetic macular edema (DME), and macular telangiectasia type 2 (MacTel) were analyzed. Automated segmentation was performed using the fluid analyzer on Skopix by NetraMind Innovations, a deep learning-based framework trained to identify intraretinal fluid (IRF), subretinal fluid (SRF), pigment epithelial detachment (PED), and subretinal hyperreflective material (SHRM). Automated segmentations were reviewed and manually corrected by two masked experienced retina graders, with discrepancies adjudicated by a senior retina specialist. Scan-level detection performance was evaluated using accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), area under the receiver operating characteristic curve (AUC), and Gwet’s first-order agreement coefficient (AC1). Spatial segmentation agreement across all B-scans was assessed using the Dice coefficient. Quantitative agreement between automated and manually corrected fluid volumes was evaluated using correlation and Bland–Altman analyses. Inter-grader reliability was assessed using the intraclass correlation coefficient (ICC). Results: A total of 98 OCT volumes comprising 31 nAMD, 25 DME, and 42 MacTel eyes were included. In nAMD, IRF detection demonstrated a sensitivity of 81.8%, specificity of 83.0%, and AUC of 0.876, while SRF demonstrated a sensitivity of 81.4%, specificity of 96.7%, and AUC of 0.901. In DME, sensitivity, specificity, and AUC were 99.6%, 97.3%, and 0.989 for IRF and 98.4%, 96.4%, and 0.978 for SRF, respectively. In MacTel, IRF demonstrated a sensitivity of 87.3%, specificity of 95.1%, and AUC of 0.927, while SRF demonstrated a sensitivity of 86.8%, specificity of 98.4%, and AUC of 0.929. Segmentation agreement between automated and manually corrected annotations was high across disease groups, with Dice coefficients of 0.829 and 0.922 for IRF and SRF in nAMD, 0.858 and 0.941 in DME, and 0.908 and 0.97 in MacTel, respectively. Automated fluid volumes demonstrated strong correlations with manually corrected measurements, with minimal systematic bias on Bland–Altman analysis. Conclusions: The automated segmentation algorithm demonstrated strong validation performance for the detection and quantitative assessment of retinal fluid across nAMD, DME, and MacTel. High segmentation agreement, particularly for IRF and SRF, and strong volumetric agreement with expert-corrected measurements support the potential use of automated OCT fluid quantification in clinical practice and research.