Mihael Makek

Prof. Mihael Makek

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2021 in Condensed Matter
Verified
Journal Article
Open access
PDF file
AKAna Marija Kožuljević
Ana Marija Kožuljević
DBDamir Bosnar
Damir Bosnar
ZKZdenka Kuncic
Zdenka Kuncic
MMMihael Makek
Mihael Makek
SPSiddharth Parashari
Siddharth Parashari
PŽPetar Žugec
Petar Žugec
When a positron annihilates, two gamma photons are created with orthogonal polarizations. It is possible to use coincidence measurements where both photons undergo Compton scattering to estimate their initial relative polarization orientation. This information is of great interest in gamma imaging systems, such as Positron Emission Tomography, where it may be used as an additional tool to distinguish true coincidence events from scatter and random background. The successful utilization of this principle critically depends on the detector’s angular and energy resolution, which determine its polarimetric performance. In this study, we use Monte Carlo simulations based on the Geant4 toolkit to model two multi-pixel detector configurations identified as prospective for the measurement of gamma-ray polarization in PET. One is based on 2 mm × 2 mm × 20 mm LYSO scintillators and the other is based on 3 mm × 3 mm × 20 mm GAGG scintillators. Each configuration has a pair of modules, each consisting of 64 crystals set up in a single 8 × 8 matrix, where both the recoil electron and the Compton-scattered photon are absorbed. We simulate positron annihilation by generating two back-to-back gamma photons of 511 keV with orthogonal polarizations. The Compton scattering is successfully identified and the modulation of the azimuthal angle difference is clearly observed. The configuration based on GAGG crystals demonstrates slightly better polarimetric performance than the one based on LYSO crystals, reflected in the more pronounced azimuthal modulation.

25 November 2020 in Crystals
Verified
Journal Article
Open access
PDF file
MMMihael Makek
Mihael Makek
DBDamir Bosnar
Damir Bosnar
AKAna Marija Kožuljević
Ana Marija Kožuljević
LPLuka Pavelić
Luka Pavelić
We investigated two detector modules, each consisting of a 8 × 8 matrix of GaGG:Ce crystals with a crystal size of 3 × 3 × 20 mm3 and a 3.2 mm pitch. The light is collected by a 8 × 8 silicon photomultiplier array, with one silicon photomultiplier matching one crystal. The signals are read out and processed using the TOFPET2 ASIC. Performed laboratory tests of the detectors were performed using a 22Na source, where energy and coincidence time resolution with different optical coupling were examined between the crystals and silicon photomultipliers, as well as under various operating voltages. The mean energy resolution of 9.8±0.6% at 511 keV was observed and it was shown that the coincidence time resolution of 384±33 ps could be achieved. The results reassure that the GaGG scintillator is a very promising candidate for the development of imaging systems, in particular, ones utilizing Compton scattering where the energy resolution plays a critical role and a moderate timing performance is acceptable.

5 April 2024 in Physics Letters B
Verified
Journal Article
Open access
SPSiddharth Parashari
Siddharth Parashari
DBDamir Bosnar
Damir Bosnar
IFIvica Friščić
Ivica Friščić
AKAna Marija Kožuljević
Ana Marija Kožuljević
ZKZdenka Kuncic
Zdenka Kuncic
MMMihael Makek
Mihael Makek

1 April 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MMMihael Makek
Mihael Makek
DBDamir Bosnar
Damir Bosnar
LPLuka Pavelić
Luka Pavelić
PŠPavla Šenjug
Pavla Šenjug
PŽPetar Žugec
Petar Žugec

21 July 2008 in Physical Review C
Verified
Journal Article
Closed access
PDF file
NSN. F. Sparveris
N. F. Sparveris
PAPatrick Achenbach
Patrick Achenbach
CGC. Ayerbe Gayoso
C. Ayerbe Gayoso
DBD. Baumann
D. Baumann
JBJ. Bernauer
J. Bernauer
MWM. Weis
M. Weis
We report on new H(e,e'p)γ measurements in the Δ(1232) resonance at Q2=0.06 (GeV/c)2 carried out simultaneously with H(e,e'p)π0. It is the lowest Q2 for which the virtual Compton scattering (VCS) reaction has been studied in the first resonance region. The VCS measured cross sections are well described by dispersion-relation calculations in which the multipole amplitudes derived from H(e,e'p)π0 data are used as input, thus confirming the compatibility of the results. The derived resonant magnetic dipole amplitude M1+3/2=(40.60±0.70stat+sys)(10−3/mπ+) at W=1232 MeV is in excellent agreement with the value extracted from H(e,e'p)π0 measurements.

16 July 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SPSiddharth Parashari
Siddharth Parashari
TBTomislav Bokulić
Tomislav Bokulić
DBDamir Bosnar
Damir Bosnar
AKAna Marija Kožuljević
Ana Marija Kožuljević
ZKZdenka Kuncic
Zdenka Kuncic
MMMihael Makek
Mihael Makek