Thomas Landry

Dr. Thomas Landry

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2011 in Hearing Research
Verified
Journal Article
Closed access
TLThomas Landry
Thomas Landry
AWAndrew K. Wise
Andrew K. Wise
JFJames B. Fallon
James B. Fallon
RSRobert K. Shepherd
Robert K. Shepherd


1 January 2022 in BME Frontiers
Verified
Journal Article
Open access
PDF file
TLThomas Landry
Thomas Landry
JGJessica Gannon
Jessica Gannon
EVEli Vlaisavljevich
Eli Vlaisavljevich
MMMatthew G. Mallay
Matthew G. Mallay
JWJeffrey K. Woodacre
Jeffrey K. Woodacre
JBJeremy A. Brown
Jeremy A. Brown
Objective . Initial performance evaluation of a system for simultaneous high-resolution ultrasound imaging and focused mechanical submillimeter histotripsy ablation in rat brains. Impact Statement . This study used a novel combination of high-resolution imaging and histotripsy in an endoscopic form. This would provide neurosurgeons with unprecedented accuracy in targeting and executing nonthermal ablations in minimally invasive surgeries. Introduction . Histotripsy is a safe and effective nonthermal focused ablation technique. However, neurosurgical applications, such as brain tumor ablation, are difficult due to the presence of the skull. Current devices are too large to use in the minimally invasive approaches surgeons prefer. We have developed a combined imaging and histotripsy endoscope to provide neurosurgeons with a new tool for this application. Methods . The histotripsy component had a 10 mm diameter, operating at 6.3 MHz. Affixed within a cutout hole in its center was a 30 MHz ultrasound imaging array. This coregistered pair was used to ablate brain tissue of anesthetized rats while imaging. Histological sections were examined, and qualitative descriptions of ablations and basic shape descriptive statistics were generated. Results . Complete ablations with submillimeter area were produced in seconds, including with a moving device. Ablation progress could be monitored in real time using power Doppler imaging, and B-mode was effective for monitoring post-ablation bleeding. Collateral damage was minimal, with a 100 μ m maximum distance of cellular damage from the ablation margin. Conclusion . The results demonstrate a promising hardware suite to enable precision ablations in endoscopic procedures or fundamental preclinical research in histotripsy, neuroscience, and cancer.

1 January 2005 in Aquaculture
Verified
Journal Article
Closed access
NLNeil LeBlanc
Neil LeBlanc
TLThomas Landry
Thomas Landry
HSHenrik Stryhn
Henrik Stryhn
RTRéjean Tremblay
Réjean Tremblay
MMMary McNiven
Mary McNiven
JDJeff Davidson
Jeff Davidson

15 February 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
CJChen Jiang
Chen Jiang
SSShreya Singhal
Shreya Singhal
TLThomas Landry
Thomas Landry
IRIwan V. Roberts
Iwan V. Roberts
SRSimone R. de Rijk
Simone R. de Rijk
MBManohar Bance
Manohar Bance
Cochlear implants use electrical stimulation of the auditory nerve to restore the sensation of hearing to deaf people. Unfortunately, the stimulation current spreads extensively within the cochlea, resulting in “blurring” of the signal, and hearing that is far from normal. Current spread can be indirectly measured using the implant electrodes for both stimulating and sensing, but this provides incomplete information near the stimulating electrode due to electrode-electrolyte interface effects. Here, we present a 3D-printed “unwrapped” physical cochlea model with integrated sensing wires. We integrate resistors into the walls of the model to simulate current spread through the cochlear bony wall, and “tune” these resistances by calibration with an in-vivo electrical measurement from a cochlear implant patient. We then use this model to compare electrical current spread under different stimulation modes including monopolar, bipolar and tripolar configurations. Importantly, a trade-off is observed between stimulation amplitude and current focusing among different stimulation modes. By combining different stimulation modes and changing intracochlear current sinking configurations in the model, we explore this trade-off between stimulation amplitude and focusing further. These results will inform clinical strategies for use in delivering speech signals to cochlear implant patients.

1 September 2014 in Hearing Research
Verified
Journal Article
Closed access
JFJames B. Fallon
James B. Fallon
RSRobert K. Shepherd
Robert K. Shepherd
DNDavid A.X. Nayagam
David A.X. Nayagam
AWAndrew K. Wise
Andrew K. Wise
LHLeon F. Heffer
Leon F. Heffer
DIDexter R.F. Irvine
Dexter R.F. Irvine