Sichao Tan

Prof. Dr. Sichao Tan


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2009 in Applied Thermal Engineering
Verified
Journal Article
Closed access
STSichao Tan
Sichao Tan
GSG.H. Su
G.H. Su
PGPu-Zhen Gao
Pu-Zhen Gao

1 October 2013 in Experimental Thermal and Fluid Science
Verified
Journal Article
Closed access
STSichao Tan
Sichao Tan
ZWZhanwei Wang
Zhanwei Wang
CWChang Wang
Chang Wang
SLShu Lan
Shu Lan

1 January 2009 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
STSichao Tan
Sichao Tan
GSG.H. Su
G.H. Su
PGPuzhen Gao
Puzhen Gao

1 July 2011 in Review of Scientific Instruments
Verified
Journal Article
Closed access
CECarlos E. Estrada-Pérez
Carlos E. Estrada-Pérez
YHYassin A. Hassan
Yassin A. Hassan
STSichao Tan
Sichao Tan
Laser induced fluorescence (LIF) is a non-intrusive optical technique that uses fluorescent dyes to measure whole-field fluid scalars such as temperature, concentration, pH, etc. LIF measurements’ accuracy is strongly influenced by the fluorescent dye's behavior under different experimental conditions. In particular, ratiometric LIF thermometry accuracy depends on the correct selection of fluorescent dyes mixtures. Therefore, a thorough characterizations of fluorescent dyes is needed to obtain optimal mixtures and suitable optical configurations for given experimental conditions. This work presents the experimental characterization of fluorescein-27 (FL27) and rhodamine-B (RhB) mixtures to determine suitable aqueous solutions for ratiometric LIF thermometry. The mixtures' fluorescence emission intensity was measured with a spectrofluorometer, and the influence of concentration ratio (\documentclass[12pt]{minimal}\begin{document}$C_{\text{RhB}}/C_{\text{FL27}}$\end{document}CRhB/CFL27), temperature, excitation wavelength (λext), and pH were analyzed. The results show that the temperature dependence of FL27 emission intensity changed from a negative to a positive value as the excitation wavelength increased. The temperature sensitivity (4.0% per °C) of RhB and FL27 mixture under 532 nm excitation wavelength was found to be higher than that of the commonly used mixture of RhB and Rh110 (2.0% per °C) at the same excitation wavelength. While the emission intensities of the dyes are sensitive to pH value, the temperature dependence is unaffected. The influence of concentration ratio on temperature sensitivity depends on both the detected bands of the emitted spectrum and the temperature; the concentration ratio should be selected based on the measured temperature scope. A new multicolor method or advanced two color method with high temperature sensitivity (6.0% or 10.0% per °C) is presented. This technique was specially developed to improve whole-field temperature measurements.

1 February 2018 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
XCXianbing Chen
Xianbing Chen
PGPuzhen Gao
Puzhen Gao
STSichao Tan
Sichao Tan
ZYZhiting Yu
Zhiting Yu
CCChong Chen
Chong Chen

1 July 2018 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
KCKun Cheng
Kun Cheng
TMTao Meng
Tao Meng
CTChunping Tian
Chunping Tian
HYHongsheng Yuan
Hongsheng Yuan
STSichao Tan
Sichao Tan