Ying Hong

Dr. Ying Hong


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2010 in Eye
Verified
Journal Article
Open access
PDF file
YHYing Hong
Ying Hong
CZC Zhang
C Zhang
WWW Wang
W Wang
The effects of phacoemulsification on intraocular pressure and the ultrasound biomicroscopic image of filtering bleb in eyes with cataract and functioning filtering blebs: comparison of the Tongren Eye Center and Peking University Eye Center data

27 June 2018 in Preprints.org
Verified
Preprint
Open access
PDF file
CWChao Wang
Chao Wang
YDYalong Dang
Yalong Dang
PSPriyal Shah
Priyal Shah
HEHamed Esfandiari
Hamed Esfandiari
YHYing Hong
Ying Hong
NLNils Loewen
Nils Loewen
Purpose: To investigate whether microsurgical excision of trabecular meshwork (TM) in an ex vivo pigmentary glaucoma model can normalize the hypertensive phenotype. Methods: Eight eyes of a porcine pigmentary glaucoma model underwent 90° of microsurgical TM excision with an aspirating dual-blade (Goniotome (G)). 24 hours later, an additional 90° of TM were removed. Anterior segments with sham surgeries served as the control (C). Outflow facility and intraocular pressure (IOP) were analyzed. Histology with hematoxylin and eosin (H&E) was obtained. Results: After the first 90° TM excision, IOP was significantly lower in G (10.23±2.39 mmHg, n=7) than C (20.04±1.97mmHg, n=8, P<0.01). Outflow facility in G (0.38±0.07 µl/min/mmHg) was higher than C (0.16±0.02 µl/min/mmHg, P<0.01). After the second 90° TM excision, IOP in G (6.46±0.81 mmHg, n=7) was significantly lower than C (20.25±1.66 mmHg, n=8, P<0.001), while the outflow facility in G (0.50±0.05 µl/min/mmHg, n=7) was higher than C (0.16±0.01 µl/min/mmHg, n=8, P<0.001). Compared to the first excision, excision of an additional 90° did not change of IOP (P=0.20) or outflow facility (P=0.17) further. Conclusion: Excision of 90° of TM in a pigmentary glaucoma model using an aspirating dual-blade decreased IOP and increased outflow facility. Translational Relevance: Microsurgical TM excision over 90° can effectively restore outflow in pigmentary glaucoma.

27 November 2018 in Preprints.org
Verified
Preprint
Open access
PDF file
YHYing Hong
Ying Hong
CWChao Wang
Chao Wang
RLRalitsa Loewen
Ralitsa Loewen
SWSusannah Waxman
Susannah Waxman
PSPriyal Shah
Priyal Shah
NLNils Loewen
Nils Loewen
Purpose: To investigate the extent of anterior chamber angle circumference needed to maintain a physiological outflow facility (C). Methods: Twenty anterior segments of porcine eyes were assigned to 5 groups, each with a different degree of cyanoacrylate-mediated angle closure: 90° (n = 4), 180° (n = 4), 270° (n = 4), 360° (n = 4) and four unoccluded control eyes. The outflow facility was measured at baseline, 3, 12, 24, and 36 hours after angle closure. Outflow patterns were evaluated with canalograms and the histomorphology was compared. Results: Baseline outflow facilities of the five groups were similar (F = 0.922, P = 0.477). Complete, circumferential occlusion over 360° induced a significant decrease in facility from baseline at all time-points (P ≤ 0.023 at 3, 12, 24 and 36 hours). However, no difference from baseline was found in any of the partially-occluded (0–270°) groups (F ≥ 0.067, P ≥ 0.296 at 3, 12, 24 and 36 hours). The canalograms confirmed the extent of occlusion with flow through the unblocked regions. Histology revealed no adverse effects of blockage on the TM or aqueous plexus in the unoccluded angle portions. The unoccluded TM appeared normal. Conclusion: Cyanoacrylate-mediated angle occlusion created a reproducible angle closure model. 90° of unoccluded anterior chamber angle circumference was sufficient to maintain physiological outflow. This model may help understand how outflow can be regulated in healthy, nonglaucomatous TM.

27 March 2018 in Preprints.org
Verified
Preprint
Open access
PDF file
YDYalong Dang
Yalong Dang
CWChao Wang
Chao Wang
PSPriyal Shah
Priyal Shah
SWSusannah Waxman
Susannah Waxman
RLRalitsa T. Loewen
Ralitsa T. Loewen
NLNils Loewen
Nils Loewen
Purpose: To evaluate three different microincisional ab interno trabeculectomy procedures in a porcine eye perfusion model. Methods: In perfused porcine anterior segments, 90 degrees of trabecular meshwork (TM) were ablated using the Trabectome (T; n = 8), Goniotome (G; n = 8), or Kahook device (K; n = 8). After 24 hours, additional 90 degrees of TM were removed. Intraocular pressure (IOP) and outflow facility were measured at 5 µL/min and 10 µL/min perfusion to simulate an elevated IOP. Structure and function were assessed with canalograms and histology. Results: At 5 µL/min infusion rate, T resulted in a greater IOP reduction than G or K from baseline (76.12% decrease versus 48.19% and 47.96%, P = 0.013). IOP reduction between G and K was similar (P = 0.420). Removing another 90 degrees of TM caused an additional IOP reduction only in T and G but not in K. Similarly, T resulted in the largest increase in outflow facility at 5 µL/min compared with G and K (first ablation: 3.41 times increase versus 1.95 and 1.87; second ablation: 4.60 versus 2.50 and 1.74) with similar results at 10 µL/min (first ablation: 3.28 versus 2.29 and 1.90 (P = 0.001); second ablation: 4.10 versus 3.01 and 2.01 (P = 0.001)). Canalograms indicated circumferential flow beyond the ablation endpoints. Conclusions: T, G and K significantly increased the outflow facility. In this model, T had a larger effect than G and K.