Stefano Bennardo

Dr. Stefano Bennardo


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2023 in Cosmetics
Verified
Journal Article
Open access
PDF file
GCGiovanni Cannarozzo
Giovanni Cannarozzo
CRChiara Del Re
Chiara Del Re
FNFrancesca Negosanti
Francesca Negosanti
SBStefano Bennardo
Stefano Bennardo
GAGiuseppe Fabrizio Amoruso
Giuseppe Fabrizio Amoruso
LBLuigi Bennardo
Luigi Bennardo
(1) Introduction: In cosmetic dermatology, benign hyperpigmentation is a prevalent issue. Solar lentigo and other melanoses are bringing patients to the attention of physicians more and more often. The Q-switched 1064/532-nanometer (nm) laser is the gold standard device to treat these conditions. A new generation of these machines, able to shorten pulse duration to hundreds of picoseconds, has emerged showing better preliminary results. In order to treat hypermelanoses in Asians, we used a Q-switched laser with a picosecond pulse. (2) Methods: A retrospective recruitment of 31 Asian individuals requesting treatment for melanosis was conducted at Catanzaro’s Magna Graecia University, University of Rome Tor Vergata and Villa Bella Antiaging. Although they might have varied, the treatment settings were typically as follows: for dermic lesions, a pulse wavelength of 1064 nm with a duration of 450 picoseconds (ps) was used, and for epidermal lesions, a pulse wavelength of 532 nm with a duration of 370 ps was used. Up to four laser treatments were carried out, each at least 30 days apart. During a three-month follow-up after the final session, patient satisfaction was evaluated using a visual analogue scale (VAS). Images taken prior to laser treatments and thereafter were compared, and the aesthetic effect was scored on a five-point scale by two blinded specialists. (3) Results: Of the 31 patients recruited, 25 (80.6%) were female and 6 were male (19.4%). The average stated age was 48.96 ± 13.68. During the dermatological examination, all patients were found to have nearly completely removed melanosis, with a mean VAS score of 7.03 ± 1.35 and a five-point evaluation scale of 2.71 ± 0.78. Conclusions: The Q-switched 1064/532 nm laser can be seen as a safe and effective option to treat benign hypermelanosis in Asian patients. Compared to other technologies, the use of a picosecond pulse appears to promise superior outcomes. To validate the results of this investigation, however, a clinical trial comparing the many commercially accessible therapy options is required.

25 March 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
MVMaria Teresa Viviano
Maria Teresa Viviano
APAlessia Provini
Alessia Provini
CMCinzia Mazzanti
Cinzia Mazzanti
Steven NisticòSteven Nisticò
Steven Nisticò
Cataldo PatrunoCataldo Patruno
Cataldo Patruno
LBLuigi Bennardo
Luigi Bennardo
A large part of the world’s population suffers from Striae distensae (SD) or stretch marks, which create physical and psychological discomfort in people. We evaluate the SD clinical improvement by using a non-ablative fractional Nd:YAP 1340 nm laser. The research was performed on 25 patients of both sexes, with a mean age of 31 ± 13.09 years. Each patient underwent from a minimum of 3 to a maximum of 4 treatments, with an Nd:YAP (1340 nm) medical device, every four weeks, with 3- and 6-month follow-up, in these areas: back, abdomen, breast, flanks, lower limbs, buttocks, and thighs. Manchester Scar Scale assessed stretch marks improvement. Side effects, patient pain, and SD overall appearance improvement were also recorded for all patients. Digital photographs measured the aesthetic results. Treatment was well-tolerated (pain score 1.08 ± 0.76) by all patients. There were no long-term side effects, and 88% of patients revealed an SD excellent improvement showing good aesthetic results achieved by the treatment. The total mean pretreatment Manchester Scar Scale score decreased from 13.80 (±1.58) to 10.36 (±1.70) after 3 months (p < 0.01) and to 8.36 (±1.07) after 6 months (p < 0.01). An Nd:YAP (1340 nm) laser seems to be a safe and effective treatment, showing a higher security profile with no side effects.

2 September 2022 in Medicina
Verified
Journal Article
Open access
PDF file
Steven NisticòSteven Nisticò
Steven Nisticò
LBLuigi Bennardo
Luigi Bennardo
SBStefano Bennardo
Stefano Bennardo
MMMiriam Marigliano
Miriam Marigliano
Elena ZappiaElena Zappia
Elena Zappia
GCGiovanni Cannarozzo
Giovanni Cannarozzo
Background and Objectives: Hair removal is a common cosmetic problem interesting more and more patients nowadays. Various laser treatments are currently available. Alexandrite and Nd:YAG laser are the most effective procedures in lighter and darker skin phototypes, respectively. Materials and Methods: A total of 40 patients seeking hair removal in one or more body areas with skin phototypes 2–6 was recruited to perform this study. Patients were divided into two groups. One group was treated with the standard Nd:YAG hair removal procedure, while the other group was treated with a new “in motion” Nd:YAG technology. Results and hair removal rates were evaluated six months after the last treatment. Results: Out of 40 patients treated, all patients experienced hair reduction. No statistically significant difference in hair removal was noted between the two groups; however, a statistically significant reduction in pain during the procedure was observed in the group treated with the “in motion” technique. Conclusions: While traditional and “in motion” Nd:YAG techniques have similar result outcomes in hair removal, the “in motion” technology seems to guarantee a better safety profile compared with the traditional technique. A more extensive clinical study will be necessary to confirm our study’s results.

3 March 2025 in Cosmetics
Verified
Journal Article
Open access
PDF file
Elena ZappiaElena Zappia
Elena Zappia
SBStefano Bennardo
Stefano Bennardo
Gaia FasanoGaia Fasano
Gaia Fasano
VRValerio Raffaele
Valerio Raffaele
TZTiziano Zingoni
Tiziano Zingoni
Steven NisticòSteven Nisticò
Steven Nisticò
Unwanted abdominal fat is a common aesthetic concern treated through various interventions, including surgical and energy-based devices, often leading to inconsistent results. This study aimed to evaluate the feasibility of a localized, non-invasive microwave (MW) device for preferential heating of subcutaneous adipose tissue using a controlled electromagnetic field. Five female volunteers scheduled for abdominoplasty were enrolled, each undergoing a single MW treatment session five days prior to surgery. Histological analyses of adipose tissue and skin samples were conducted using Hematoxylin and Eosin staining and immunohistochemistry for Perilipin-1 and CD68. Epidermal and dermal layers remained unaffected, as evidenced by unaltered morphology in treated samples. In contrast, the absence of Perilipin-1 expression in disrupted fat cell membranes indicated adipocyte non-viability and irreversible injury. Inflammatory responses, including CD68-positive macrophages surrounding damaged adipocytes, were observed, suggesting the activation of the monocyte/macrophage system for the clearance of adipocyte residues. Microscopic and immunohistochemical findings demonstrate the effectiveness of the MW device in reducing subcutaneous fat. This study also discussed the underlying mechanisms involved in macrophage recruitment and the removal of adipocyte residues.

30 March 2023 in Cosmetics
Verified
Journal Article
Open access
PDF file
LBLuigi Bennardo
Luigi Bennardo
Steven NisticòSteven Nisticò
Steven Nisticò
GPGrazia Primavera
Grazia Primavera
MTMartina Tolone
Martina Tolone
FTFederica Tamburi
Federica Tamburi
GCGiovanni Cannarozzo
Giovanni Cannarozzo
Background and Objectives: Hair removal is a common aesthetic concern for patients referred to dermatologists and aesthetic physicians. Lasers and lights are one of the mainstays in the management of this condition. Among these devices, intense pulsed lights (IPLs) are broadly used in order to reduce the number and width of the hair present. Currently used techniques are associated with a high risk of side effects, such as hyper or hypopigmentation. Materials and Methods: Thirty patients seeking hair removal in one or more body areas with skin phototypes 1 to 4 were recruited to perform this study. All areas to be treated were divided into two equal regions; one side was treated with the standard IPL hair removal procedure, while the other was treated with a new “in-motion” IPL technology. Results and hair removal rates were evaluated six months after the last treatment. Results: Out of the 30 patients treated, all patients experienced hair reduction. No statistically significant difference in hair removal was noted among the two sides. A statistically significant reduction in pain during the procedure was observed in the side treated with the “in-motion” technique. Conclusions: Traditional and “in-motion” IPL techniques have similar results in hair removal; the “in-motion” technology seems to guarantee a better safety profile than the traditional technique, as well as maintains the same results over time and a faster treatment time. A more extensive clinical study will be necessary to confirm our study’s results.