Key points: What is already known about this topic? In 2015, the International Society for Prenatal Diagnosis (ISPD) published its first position statement on the use of non‐invasive prenatal testing (NIPT) to screen for aneuploidy. Widespread uptake across the globe and subsequent published research has shed new light on test performance and implementation issues. What does this study add? This new position statement replaces the 2015 statement with updated information on the current technologies, clinical experience, and implementation practices. As an international organization, ISPD recognizes that there are important population‐specific considerations in the organization of prenatal screening and diagnosis. These opinions are designed to apply to high income settings where prenatal screening for aneuploidy is an established part of antenatal care. This position statement is not a clinical practice guideline but represents the consensus opinion of the current ISPD Board based on the current state of knowledge and clinical practice.
Non-invasive prenatal testing (NIPT) identifies fetal aneuploidy by sequencing cell-free DNA in the maternal plasma. Pre-symptomatic maternal malignancies have been incidentally detected during NIPT based on abnormal genomic profiles. This low coverage sequencing approach could have potential for ovarian cancer screening in the non-pregnant population. Our objective was to investigate whether plasma DNA sequencing with a clinical whole genome NIPT platform can detect early- and late-stage high-grade serous ovarian carcinomas (HGSOC). This is a case control study of prospectively-collected biobank samples comprising preoperative plasma from 32 women with HGSOC (16 ‘early cancer’ (FIGO I–II) and 16 ‘advanced cancer’ (FIGO III–IV)) and 32 benign controls. Plasma DNA from cases and controls were sequenced using a commercial NIPT platform and chromosome dosage measured. Sequencing data were blindly analyzed with two methods: (1) Subchromosomal changes were called using an open source algorithm WISECONDOR (WIthin-SamplE COpy Number aberration DetectOR). Genomic gains or losses ≥ 15 Mb were prespecified as “screen positive” calls, and mapped to recurrent copy number variations reported in an ovarian cancer genome atlas. (2) Selected whole chromosome gains or losses were reported using the routine NIPT pipeline for fetal aneuploidy. We detected 13/32 cancer cases using the subchromosomal analysis (sensitivity 40.6 %, 95 % CI, 23.7–59.4 %), including 6/16 early and 7/16 advanced HGSOC cases. Two of 32 benign controls had subchromosomal gains ≥ 15 Mb (specificity 93.8 %, 95 % CI, 79.2–99.2 %). Twelve of the 13 true positive cancer cases exhibited specific recurrent changes reported in HGSOC tumors. The NIPT pipeline resulted in one “monosomy 18” call from the cancer group, and two “monosomy X” calls in the controls. Low coverage plasma DNA sequencing used for prenatal testing detected 40.6 % of all HGSOC, including 38 % of early stage cases. Our findings demonstrate the potential of a high throughput sequencing platform to screen for early HGSOC in plasma based on characteristic multiple segmental chromosome gains and losses. The performance of this approach may be further improved by refining bioinformatics algorithms and targeting selected cancer copy number variations.
While being small-for-gestational-age due to placental insufficiency is a major risk factor for stillbirth, 50% of stillbirths occur in appropriate-for-gestational-age (AGA, > 10th centile) fetuses. AGA fetuses are plausibly also at risk of stillbirth if placental insufficiency is present. Such fetuses may be expected to demonstrate declining growth trajectory across pregnancy, although they do not fall below the 10th centile before birth. We investigated whether reduced growth velocity in AGA fetuses is associated with antenatal, intrapartum and neonatal indicators of placental insufficiency. We performed a prospective cohort study of 308 nulliparous women who subsequently gave birth to AGA infants. Ultrasound was utilised at 28 and 36 weeks’ gestation to determine estimated fetal weight (EFW) and abdominal circumference (AC). We correlated relative EFW and AC growth velocities with three clinical indicators of placental insufficiency, namely (1) fetal cerebroplacental ratio (CPR; CPR < 5th centile reflects placental resistance, and blood flow redistribution to the brain – a fetal response to hypoxia); (2) neonatal acidosis after the hypoxic challenge of labour (umbilical artery (UA) pH < 7.15 at birth); and (3) low neonatal body fat percentage (BF%, measured by air displacement plethysmography) reflecting reduced nutritional reserve in utero. For each one centile reduction in EFW growth velocity between 28 and 36 weeks’ gestation, there was a 2.4% increase in the odds of cerebral redistribution (CPR < 5th centile, odds ratio (OR) (95% confidence interval) = 1.024 (1.005–1.042), P = 0.012) and neonatal acidosis (UA pH < 7.15, OR = 1.024 (1.003–1.046), P = 0.023), and a 3.3% increase in the odds of low BF% (OR = 1.033 (1.001–1.067), P = 0.047). A decline in EFW of > 30 centiles between 28 and 36 weeks (compared to greater relative growth) was associated with cerebral redistribution (CPR < 5th centile relative risk (RR) = 2.80 (1.25–6.25), P = 0.026), and a decline of > 35 centiles was associated with neonatal acidosis (UA pH < 7.15 RR = 3.51 (1.40–8.77), P = 0.030). Similar associations were identified between low AC growth velocity and clinical indicators of placental insufficiency. Reduced growth velocity between 28 and 36 weeks’ gestation among fetuses born AGA is associated with antenatal, intrapartum and neonatal indicators of placental insufficiency. These fetuses potentially represent an important unrecognised cohort at increased risk of stillbirth and may warrant more intensive antenatal surveillance.