Myriam Cristina Jimenez Mares

Dr. Myriam Cristina Jimenez Mares

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2024 in Optical Fiber Technology
Verified
Journal Article
Closed access
LGLuis Enrique Guillen
Luis Enrique Guillen
GAGilberto Anzueto-Sánchez
Gilberto Anzueto-Sánchez
AMAlejandro Martinez-Rios
Alejandro Martinez-Rios
MMMyriam Cristina Jimenez Mares
Myriam Cristina Jimenez Mares
JCJ.L. Camas-Anzueto
J.L. Camas-Anzueto

6 October 2026 in Photonics
Verified
Journal Article
Open access
PDF file
JVJavier Antonio Martin Vela
Javier Antonio Martin Vela
Gilberto Anzueto-SánchezGilberto Anzueto-Sánchez
Gilberto Anzueto-Sánchez
AMAlejandro Martinez-Rios
Alejandro Martinez-Rios
LGLuis Enrique Guillen-Ruiz
Luis Enrique Guillen-Ruiz
AAANA ISABEL ORTEGA AGREDO
ANA ISABEL ORTEGA AGREDO
LRLuis Alberto Rodriguez-Morales
Luis Alberto Rodriguez-Morales
A wavelength-selectable passively Q-switched erbium-doped fiber laser (EDFL) is experimentally demonstrated as a pulsed laser source for addressing selected acetylene P-branch absorption lines near 1.53 μm. The cavity combines interchangeable fiber Bragg gratings (FBGs) for coarse wavelength selection with temperature control of the selected FBG for fine wavelength positioning. Target absorption transitions were identified from the HITRAN database; their line positions were converted to the wavelength convention used in the experimental plots, giving P(7), P(9) and P(11) reference wavelengths of 1528.76 nm, 1529.94 nm, and 1531.17 nm, respectively. The laser output was amplified and launched into an acetylene-filled hollow-core fiber (HCF), and the transmitted spectra were monitored during gas filling and FBG thermal tuning. The source exhibited passively Q-switched operation from approximately 7 to 30 kHz over the investigated pump-power range, with pulse widths decreasing from about 12.3 μs to 3.5–4.0 μs. Short-term spectral measurements showed no resolvable central-wavelength drift within the 0.05 nm resolution of the optical spectrum analyzer (OSA) over 30 min. Thermal tuning produced relative transmission minima near the selected P-branch spectral positions, consistent with increased laser–line spectral overlap; these minima are used as wavelength-positioning indicators rather than quantitative absorption measurements. The results establish a compact wavelength-selectable pulsed source architecture for acetylene-filled HCF experiments and related gas–fiber photonic systems.