Andreas Baranowski

Dr. Andreas Baranowski

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2008 in The American Journal of Cardiology
Verified
Journal Article
Closed access
MTMargaret Taaffe
Margaret Taaffe
EFEvelyn Fischer
Evelyn Fischer
ABAndreas Baranowski
Andreas Baranowski
NMNicolas Majunke
Nicolas Majunke
CHCorinna Heinisch
Corinna Heinisch
HSHorst Sievert
Horst Sievert

1 February 2009 in The American Journal of Cardiology
Verified
Journal Article
Closed access
NMNicolas Majunke
Nicolas Majunke
JBJacek Bialkowski
Jacek Bialkowski
NWNeil Wilson
Neil Wilson
MSMalgorzata Szkutnik
Malgorzata Szkutnik
JKJacek Kusa
Jacek Kusa
HSHorst Sievert
Horst Sievert

25 April 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ABAndreas Baranowski
Andreas Baranowski
AKAnja Klein
Anja Klein
URUlrike Ritz
Ulrike Ritz
AAAngelika Ackermann
Angelika Ackermann
JAJoris Anthonissen
Joris Anthonissen
AHAlexander Hofmann
Alexander Hofmann
Orthopedic implant failure due to aseptic loosening and mechanical instability remains a major problem in total joint replacement. Improving osseointegration at the bone-implant interface may reduce micromotion and loosening. Bone sialoprotein (BSP) has been shown to enhance bone formation when coated onto titanium femoral implants and in rat calvarial defect models. However, the most appropriate method of BSP coating, the necessary level of BSP coating, and the effect of BSP coating on cell behavior remain largely unknown. In this study, BSP was covalently coupled to titanium surfaces via an aminosilane linker (APTES), and its properties were compared to BSP applied to titanium via physisorption and untreated titanium. Cell functions were examined using primary human osteoblasts (hOBs) and L929 mouse fibroblasts. Gene expression of specific bone turnover markers at the RNA level was detected at different intervals. Cell adhesion to titanium surfaces treated with BSP via physisorption was not significantly different from that of untreated titanium at any time point, whereas BSP application via covalent coupling caused reduced cell adhesion during the first few hours in culture. Cell migration was increased on titanium disks that were treated with higher concentrations of BSP solution, independent of the coating method. During the early phases of hOB proliferation, a suppressive effect of BSP was observed independent of its concentration, particularly when BSP was applied to the titanium surface via physisorption. Although alkaline phosphatase activity was reduced in the BSP-coated titanium groups after 4 days in culture, increased calcium deposition was observed after 21 days. In particular, the gene expression level of RUNX2 was upregulated by BSP. The increase in calcium deposition and the stimulation of cell differentiation induced by BSP highlight its potential as a surface modifier that could enhance the osseointegration of orthopedic implants. Both physisorption and covalent coupling of BSP are similarly effective, feasible methods, although a higher BSP concentration is recommended.

Verified
Journal Article
Open access
PDF file
ALAlina Lauer
Alina Lauer
PWPhilipp Wolf
Philipp Wolf
DMDorothea Mehler
Dorothea Mehler
HGHermann Götz
Hermann Götz
MRMehmet Rüzgar
Mehmet Rüzgar
URUlrike Ritz
Ulrike Ritz
Large segmental bone defects occurring after trauma, bone tumors, infections or revision surgeries are a challenge for surgeons. The aim of our study was to develop a new biomaterial utilizing simple and cheap 3D-printing techniques. A porous polylactide (PLA) cylinder was printed and functionalized with stromal-derived factor 1 (SDF-1) or bone morphogenetic protein 7 (BMP-7) immobilized in collagen type I. Biomechanical testing proved biomechanical stability and the scaffolds were implanted into a 6 mm critical size defect in rat femur. Bone growth was observed via x-ray and after 8 weeks, bone regeneration was analyzed with µCT and histological staining methods. Development of non-unions was detected in the control group with no implant. Implantation of PLA cylinder alone resulted in a slight but not significant osteoconductive effect, which was more pronounced in the group where the PLA cylinder was loaded with collagen type I. Addition of SDF-1 resulted in an osteoinductive effect, with stronger new bone formation. BMP-7 treatment showed the most distinct effect on bone regeneration. However, histological analyses revealed that newly formed bone in the BMP-7 group displayed a holey structure. Our results confirm the osteoinductive character of this 3D-biofabricated cell-free new biomaterial and raise new options for its application in bone tissue regeneration.

1 July 2019 in Drug Design, Development and Therapy
Verified
Journal Article
Open access
PDF file
ABAndreas Baranowski
Andreas Baranowski
LSLudwig Schlemmer
Ludwig Schlemmer
KFKatharina Förster
Katharina Förster
ESEkaterina Slotina
Ekaterina Slotina
TMTim Mickan
Tim Mickan
PRPol M Rommens
Pol M Rommens
Background: After a trauma, exuberant tissue healing with fibrosis of the joint capsule can lead to posttraumatic joint stiffness (PTJS). Losartan and atorvastatin have both shown their antifibrotic effects in different organ systems. Objective: The purpose of this study was the evaluation of the influence of losartan and atorvastatin on the early development of joint contracture. In addition to joint angles, the change in myofibroblast numbers and the distribution of bone sialoprotein (BSP) were assessed. Study design and methods: In this randomized and blinded experimental study with 24 rats, losartan and atorvastatin were compared to a placebo. After an initial joint injury, rat knees were immobilized with a Kirschner wire. Rats received either losartan, atorvastatin or a placebo orally daily. After 14 days, joint angle measurements and histological assessments were performed. Results: Losartan increased the length of the inferior joint capsule. Joint angle and other capsule length measurements did not reveal significant differences between both drugs and the placebo. At cellular level both losartan and atorvastatin reduced the total number of myofibroblasts (losartan: 191±77, atorvastatin: 98±58, placebo: 319±113 per counting field, p<0.01) and the percentage area of myofibroblasts (losartan: 2.8±1.8% [p<0.05], atorvastatin: 2.5±1.7% [p<0.01], vs control [6.4±4%], respectively). BSP was detectable in equivalent amounts in the joint capsules of all groups with only a trend toward a reduction of the BSP-stained area by atorvastatin. Conclusion: Both atorvastatin and losartan reduced the number of myofibroblasts in the posterior knee joint capsule of rat knees 2 weeks after trauma and losartan increased the length of the inferior joint capsule. However, these changes at the cellular level did not translate an increase in range of motion of the rats´ knee joints during early contracture development.

12 March 2016 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
URU. Ritz
U. Ritz
TNT. Nusselt
T. Nusselt
ASA. Sewing
A. Sewing
TZThomas Ziebart
Thomas Ziebart
KKK. Kaufmann
K. Kaufmann
AHAlexander Hofmann
Alexander Hofmann