Samuel Adema

Mr. Samuel Adema

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
SASamah Alharbi
Samah Alharbi
Sijung HuSijung Hu
Sijung Hu
DMDavid Mulvaney
David Mulvaney
LBLaura Barrett
Laura Barrett
LYLiangwen Yan
Liangwen Yan
SASamuel Adema
Samuel Adema
Photoplethysmography (PPG) based pulse oximetry devices normally use red and infrared illuminations to obtain oxygen saturation (SpO 2 ) readings. In addition, the presence of motion artefacts severely restricts the utility of pulse oximetry physiological measurements. In the current study, a combination of green and orange illuminations from a multi-wavelength optoelectronic patch sensor (mOEPS) was investigated in order to improve robustness to subjects’ movements in the extraction of SpO 2 measurement. The experimental protocol with 31 healthy subjects was divided into two sub-protocols, and was designed to determine SpO 2 measurement. The datasets for the first sub-protocol were collected from 15 subjects at rest, with the subjects free to move their hands. The datasets for the second sub-protocol with 16 subjects were collected during cycling and walking exercises. The results showed good agreement with SpO 2 measurements (r = 0.98) in both sub-protocols. The outcomes promise a robust and cost-effective approach of physiological monitoring with the prospect of providing health monitoring that does not restrict user physical movements.

24 October 2018 in Preprints.org
Verified
Preprint
Open access
SASamah Alharbi
Samah Alharbi
Sijung HuSijung Hu
Sijung Hu
DMDavid Mulvaney
David Mulvaney
LBLaura Barrett
Laura Barrett
LYLiangwen Yan
Liangwen Yan
SASamuel Adema
Samuel Adema
Photoplethysmography (PPG) based pulse oximetry devices normally use red and infrared illuminations to obtain oxygen saturation (SpO2) readings. In addition, the presence of motion artefacts severely restricts the utility of pulse oximetry physiological measurements. In the current study, a combination of green and orange illuminations from a multi-wavelength optoelectronic patch sensor (mOEPS) was investigated in order to improve robustness to subjects’ movements in the extraction of SpO2 measurement. Two experimental protocols with 31 healthy subjects were designed to determine SpO2 measurement. The datasets for the first protocol were collected from 15 subjects at rest, with the subjects free to move their hands. The datasets for the second protocol with 16 subjects were collected during cycling and running exercises. The results showed good agreements with SpO2 measurements (r = 0.98) in the both protocols. The outcomes promise a robust and cost-effective approach of physiological monitoring with the prospect of providing health monitoring that does not restrict user physical movements.