Pontie Maxime

Prof. Pontie Maxime

Department of Chemistry, Angers University, Faculty of sciences, 2 Bd Lavoisier, Manager of the Group Analysis and Processes, F-49045 Angers CEDEX 01, France
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2021 in Journal of Applied Electrochemistry
Verified
Journal Article
Closed access
PDF file
Mehri ShabaniMehri Shabani
Mehri Shabani
Pontie MaximePontie Maxime
Pontie Maxime
HYHabibollah Younesi
Habibollah Younesi
MNMouna Nacef
Mouna Nacef
ARAhmad Rahimpour
Ahmad Rahimpour
RKRacha Medjda Bouchenak Khelladi
Racha Medjda Bouchenak Khelladi

25 May 2011 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
Pontie MaximePontie Maxime
Pontie Maxime
GTG. Thouand
G. Thouand
FNF. De Nardi
F. De Nardi
ITIssa Tapsoba
Issa Tapsoba
SLS. Lherbette
S. Lherbette

1 January 2013 in Desalination and Water Treatment
Verified
Journal Article
Open access
Pontie MaximePontie Maxime
Pontie Maxime
JDJ.S. Derauw
J.S. Derauw
SPS. Plantier
S. Plantier
LEL. Edouard
L. Edouard
LBL. Bailly
L. Bailly
We present the possibility to replace the first-stage reverse osmosis (RO) seawater by nanofiltration (NF) membranes. Then, we tested few membranes in the laboratory (NF200, NF2540, MPS44, and MPS34) on synthetic and natural seawater, for 2.6 m2 membrane area pilot. We observed that the membrane NF200 is the best membrane from all tested due to its higher productivity with 1.8 L h−1 m−2 bar−1 and its higher salt rejection with 60%. Furthermore, as expected, NF200 filtration of natural seawater permits to decrease SDI3 to a value of 4 ± 2%/min and total organic carbon under 0.1 mg/L, eliminating totally the risk of biofouling development on second-stage RO treatment. The configuration NF200-SW30 gave the best energy gain with 29%. The permeate obtained presents a total dissolved solids of 324 ppm and the flow yield ratio increase of 16%, in reference to SW30-SW30 configuration. Also, we tested the limits of ROSATM simulation, especially for NF membranes. We observed lots of flaws, especially for high pressures and high salts concentrations. As a consequence, each simulation realized for NF must be validated by experiments on real seawater to a sufficient scale and during sufficient time of experiments.

1 February 2015 in Desalination and Water Treatment
Verified
Journal Article
Open access
Pontie MaximePontie Maxime
Pontie Maxime
The overall objective of the present work was to estimate the degradation level of old reverse osmosis (RO) membranes in terms of permeability and salt rejection, along with their potential reuse as ultrafiltration (UF) membranes after NaOCl oxidation at 62,500 ppm for 3 h. Detailed study of old RO membrane materials deconstruction has also resulted in recommendations in their reuse as geotextile, mouse pad, support for children drawings, protection to snake attack, and aromatic wall in familial kitchen; all being alternatives solutions to incineration. At the end of the work, 95% of the old RO membrane materials were recycled.

1 January 2013 in Desalination and Water Treatment
Verified
Journal Article
Open access
Pontie MaximePontie Maxime
Pontie Maxime
HDHanane Dach
Hanane Dach
ALAbdekhaadi Lhassani
Abdekhaadi Lhassani
CDCourfia Kéba Diawara
Courfia Kéba Diawara
The possibility of producing drinking water from brackish groundwater polluted with F− using nanofiltration (NF) process was previously studied at a pilot scale. Brackish groundwaters were taken from the south of Morocco (Tan Tan city) and from the center west of Senegal (Thiadiaye City). The performances of few commercialized NF spiral wound elements, low-pressure reverse osmosis (LPRO), and reverse osmosis (RO) were compared to a large-scale pilot experiments (membrane area, 7.6 m2). The following parameters were determined: hydraulic permeability, total salinity; and Cl−, F−, and SO4 2− removals were compared under the influence of various experimental parameters such as flow yield ratio, transmembrane pressure, energy consumption and water compositions before and after treatment. This study shows that NF provides specific advantages for fluoride removal as compared to LPRO and RO. Indeed, NF permits to reduce partially the total salinity and to reject selectively fluorides with a high flow yield ratio, at low pressure (lower than 20 bars) and therefore with a low energy consumption as compared to actual RO membranes. Furthermore, this paper presents the first NF plant in the world dedicated to water defluoridation by nanofiltration and built recently in Thiadiaye (Senegal) (fresh water production 33,000 L/h).

1 March 2004 in Journal of Membrane Science
Verified
Journal Article
Closed access
QNQuang Trong Nguyen
Quang Trong Nguyen
KGKarine Glinel
Karine Glinel
Pontie MaximePontie Maxime
Pontie Maxime
ZPZhenghua Ping
Zhenghua Ping