Bone loss caused by cysts, tumors, trauma, and other factors is a significant challenge in medicine and dentistry. Effective bone regeneration is essential for accelerated healing and improved bone volume. While systemic drug supplementation helps, local delivery through gbr/gtr membranes is preferred for targeted treatment with minimal systemic effects. This study aims to develop drug-loaded gbr membranes using electrospinning to enhance localized drug delivery and tissue regeneration. Polycaprolactone (PCL) membranes were produced via electrospinning with various concentrations and solvent ratios. Therapeutic agents—pentoxifylline, carrageenan, and sodium fluoride—were incorporated into the membranes. Morphological analysis was performed using scanning electron microscopy (SEM), mechanical properties were assessed through tensile testing, structural characterization was done via Fourier-transform infrared spectroscopy (FTIR), and thermal properties were evaluated with thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC). Drug release behavior was studied using UV-Vis spectrophotometry. SEM revealed optimal fiber morphology in membranes with 10% PCL and 1% pentoxifylline, 0.5% NaF, and 1% carrageenan. Tensile strength was highest in 10% PCL membranes (2.5 MPa), outperforming 12% PCL (1.8 MPa). FTIR and TGA confirmed successful drug incorporation and thermal stability, with decomposition temperatures ranging from 395 °C to 510.9 °C. UV-Vis showed effective drug release, with 2% pentoxifylline achieving the highest release at 2 h (34%) and 4 h (62%), demonstrating enhanced performance for localized drug delivery. PCL-based electrospun membranes with therapeutic agents were successfully developed, exhibiting promising characteristics for localized drug delivery and tissue regeneration. These membranes showed comparable mechanical properties to commercial GBR/GTR membranes. Future research should focus on optimizing formulations and evaluating clinical efficacy.

1 January 2024 in International Journal of Medical Sciences
Verified
Journal Article
Open access
PDF file
AKAbdulsamet Kundakcioglu
Abdulsamet Kundakcioglu
BGBetul Gedik
Betul Gedik
Purpose: This study aimed to assess subperiosteal implants concerning bone stress and screw displacement, utilizing finite element analysis to determine the optimal screw diameter for enhanced bone support.

11 November 2024 in International Journal of Medical Sciences
Verified
Journal Article
Open access
PDF file
MAMustafa Ayhan
Mustafa Ayhan
BGBetul Gedik
Betul Gedik
EKEkrem Emir Kalelioglu
Ekrem Emir Kalelioglu
AKAbdulsamet Kundakcioglu
Abdulsamet Kundakcioglu
CKCanan Kucukgergin
Canan Kucukgergin
MYMehmet Yaltirik
Mehmet Yaltirik
Background: This study aims to investigate the effectiveness of lasers at various wavelengths in treating medication-related osteonecrosis of the jaw (MRONJ) using biochemical, clinical scoring, micro CT analysis, and histopathological methods. The study follows the ARRIVE guidelines to ensure robust and transparent research.

29 September 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
BYBasak Keskin Yalcin
Basak Keskin Yalcin
BGBetul Gedik
Betul Gedik
EEEda Etik
Eda Etik
ACAbdulkadir Burak Cankaya
Abdulkadir Burak Cankaya
MEMehmet Ali Erdem
Mehmet Ali Erdem
HBHulya Kocak Berberoglu
Hulya Kocak Berberoglu
Implant drills are essential for precise osteotomy preparation, and their repeated use can affect surface integrity, sharpness, and material loss. This original study presents a comprehensive evaluation of four implant drill systems—conventional stainless steel drills (CS), hard-coated stainless steel drills (HCS), ceramic drills (CD), and tapered expansion drills (TE)—by assessing cutting edge wear, surface roughness, and material loss at defined usage intervals. A total of 160 osteotomies were performed on fresh bovine rib bone blocks using four different drill systems. Each group included 40 repetitions. Each drill was analyzed at baseline and after 10, 20, 30, and 40 osteotomies. Drilling was performed under standardized parameters (23 °C, 800 rpm, 2 kg axial load, 50 mL/min irrigation). Surface roughness was measured using a stylus-based contact profilometer. SEM was used for morphological inspection, and a precision analytical balance (± 0.0001 g) was used to detect material loss. No significant material loss was observed in any group during the first 20 osteotomies. The ceramic drills demonstrated zero material loss and minimal surface wear across all time points. HCS drills showed the highest variability in mass loss (up to 136.5 µg), and TE drills exhibited visible edge degradation after 30 uses. SEM revealed progressive morphological changes, including edge rounding and microcracks, predominantly in HCS and TE groups. While differences between groups were not statistically significant, ceramic drills consistently demonstrated superior structural preservation. Repeated use of implant drills results in gradual wear, particularly in metallic systems. Ceramic drills exhibited the most stable performance, suggesting their potential advantage for extended clinical use.

27 June 2025 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
BGBetul Gedik
Betul Gedik
MEMehmet Ali Erdem
Mehmet Ali Erdem
Oroantral fistula (OAF) is a pathological communication between the oral cavity and the maxillary sinus, most commonly resulting from maxillary molar extractions. While traditional surgical techniques such as buccal advancement or palatal flaps have demonstrated efficacy in achieving closure, they may lead to complications including vestibular shortening, mucosal tension, and interference with prosthetic rehabilitation. This case report presents a novel technique for OAF closure involving the mobilization of palatal submucosal tissue anchored to the buccal bone, thereby eliminating the need for buccal flap advancement. Applied in 2 male patients with postextraction OAF, the method preserved soft tissue architecture, reduced surgical morbidity, and facilitated future prosthetic planning. Both patients exhibited complete closure without recurrence or significant postoperative complications. This approach offers a minimally invasive, anatomically respectful, and prosthetically favorable alternative to conventional OAF repair techniques.

20 August 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
BGBetul Gedik
Betul Gedik
MKMetin Berk Kasapoglu
Metin Berk Kasapoglu
GDGulce Ecem Dogancali
Gulce Ecem Dogancali
GUGozde Gokce Uckun
Gozde Gokce Uckun
ACAbdulkadir Burak Cankaya
Abdulkadir Burak Cankaya
MEMehmet Ali Erdem
Mehmet Ali Erdem
This study aimed to investigate the influence of different titanium mesh thicknesses (0.1 mm, 0.2 mm, and 0.3 mm) on mechanical durability and stress distribution in guided bone regeneration using finite element analysis (FEA). Three-dimensional mandibular bone models were reconstructed from cone-beam computed tomography (CBCT) data of a patient with a posterior alveolar defect. Custom titanium meshes with varying thicknesses were designed and virtually applied to the defect area. All models were subjected to a vertical force of 30 N to simulate masticatory loading. FEA simulations were performed using ALTAIR Hypermesh and OptiStruct software to evaluate von Mises stress distribution across the mesh, graft, and bone. The 0.1 mm mesh exhibited the highest stress concentrations (981.569 MPa), indicating a high risk of plastic deformation and potential graft damage (35.287 MPa). The 0.2 mm mesh provided moderate protection with improved stress distribution (mesh: 452.218 MPa, graft: 11.589 MPa). The 0.3 mm mesh showed the best mechanical performance, with the lowest stress values on both the mesh (226.205 MPa) and the graft (7.785 MPa). Bone stress remained below critical thresholds in all models. Mesh thickness significantly affects the mechanical behavior and stress shielding capacity of titanium meshes in GBR applications. A thickness of 0.3 mm offers the most reliable mechanical performance. However, 0.2 mm meshes may serve as a viable alternative in cases requiring greater flexibility or lower cost, with caution toward borderline graft stress.