Shiv Subedi

Dr. Shiv Subedi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in The Astrophysical Journal
Verified
Journal Article
Closed access
SSShiv Subedi
Shiv Subedi
ZMZach Meisel
Zach Meisel
GMGrant Merz
Grant Merz
Recent observational advances have enabled high resolution mapping of 44Ti in core-collapse supernova (CCSN) remnants. Comparisons between observations and models provide stringent constraints on the CCSN mechanism. However, past work has identified several uncertain nuclear reaction rates that influence 44Ti and 56Ni production in postprocessing model calculations. We evolved one-dimensional models of 15 M ⊙, 18 M ⊙, 22 M ⊙, and 25 M ⊙ stars from zero age main sequence through CCSN using Modules for Experiments in Stellar Astrophysics and investigated the previously identified reaction rate sensitivities of 44Ti and 56Ni production. We tested the robustness of our results by making various assumptions about the CCSN explosion energy and mass cut. We found a number of reactions that have a significant impact on the nucleosynthesis of 44Ti and 56Ni, particularly for lower progenitor masses. Notably, the reaction rates , , , , , , , , , , and are influential for a large number of model conditions. Furthermore, we found the list of influential reactions identified by previous postprocessing studies of CCSN shock-driven nucleosynthesis is likely incomplete, motivating future larger-scale sensitivity studies.

1 February 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MFM. Febbraro
M. Febbraro
BBB. Becker
B. Becker
RDR.J. Deboer
R.J. Deboer
KBK. Brandenburg
K. Brandenburg
CBC. Brune
C. Brune
RTR. Toomey
R. Toomey

2 May 2024 in Physical Review C
Verified
Journal Article
Closed access
AVA. V. Voinov
A. V. Voinov
MHM. Hartos
M. Hartos
CBC. R. Brune
C. R. Brune
SGS. M. Grimes
S. M. Grimes
YJY. Jones-Alberty
Y. Jones-Alberty
SSShiv Subedi
Shiv Subedi

13 February 2025 in Radiation Measurements
Verified
Journal Article
Closed access
SSShiv Subedi
Shiv Subedi
SCSimon R. Cherry
Simon R. Cherry
YQYi Qiang
Yi Qiang
PPPeng Peng
Peng Peng

2 June 2025 in Physical Review C
Verified
Journal Article
Closed access
GOG. Owens-Fryar
G. Owens-Fryar
SLStephanie M Lyons
Stephanie M Lyons
ARA. L. Richard
A. L. Richard
ASA. Spyrou
A. Spyrou
ABAlex Brown
Alex Brown
ATA. Tsantiri
A. Tsantiri

13 October 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
SSShiv Subedi
Shiv Subedi
SDSree Bash Chandra Debnath
Sree Bash Chandra Debnath
Optical fiber-based inorganic scintillating detectors (ISDs) are increasingly investigated for radiation therapy applications, including microbeam and ultra-high-dose-rate dosimetry. Accurate characterization of these compact detectors is particularly important for proton beams delivered under high-flux and FLASH conditions. Simplified analytical and ray-tracing models can estimate detector saturation limits but may inadequately account for internal optical scattering and the fiber insertion geometry within the scintillating volume, leading to inaccurate estimates of the effective sensitive volume and dose-rate response. In this study, we developed a detailed computational framework that explicitly models the fiber–scintillator geometry and volumetric optical photon transport. Five detector geometries with different sensitive volumes were evaluated under 25 and 230 MeV proton irradiation using a fully volumetric GATE Monte Carlo optical transport model incorporating intra-dosimeter optical scattering. The results revealed a clear inverse relationship between detector sensitive volume and maximum measurable dose rate before saturation. At 25 MeV, the maximum measurable dose rate (D˙max) ranged from 364.5 ± 7.6 Gy/s for the smallest detector to 13.5 ± 0.2 Gy/s for the largest detector, while at 230 MeV, it ranged from 392.6 ± 8.1 Gy/s down to 15.6 ± 0.3 Gy/s at 230 MeV, respectively. These findings demonstrate that fiber insertion geometry and volumetric optical scattering significantly influence the dose-rate response and saturation threshold of scintillating micro-probes. Accurate modeling of these effects is therefore essential for optimizing detector geometry, establishing reliable quantitative dosimetry across conventional and proton-FLASH dose-rate regimes.