Zhaoan Yu

Dr. Zhaoan Yu


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2015 in Discover Nano
Verified
Journal Article
Open access
PDF file
GWGuoming Wang
Guoming Wang
SLShibing Long
Shibing Long
ZYZhaoan Yu
Zhaoan Yu
MZMeiyun Zhang
Meiyun Zhang
YLYang Li
Yang Li
MLMing Liu
Ming Liu
Further performance improvement is necessary for resistive random access memory (RRAM) to realize its commercialization. In this work, a novel pulse operation method is proposed to improve the performance of RRAM based on Ti/HfO2/Pt structure. In the DC voltage sweep of the RRAM device, the SET transition is abrupt under positive bias. If current sweep with positive bias is utilized in SET process, the SET switching will become gradual, so SET is current controlled. In the negative voltage sweep for RESET process, the change of current with applied voltage is gradual, so RESET is voltage controlled. Current sweep SET and voltage sweep RESET shows better controllability on the parameter variation. Considering the SET/RESET characteristics in DC sweep, in the corresponding pulse operation, the width and height of the pulse series can be adjusted to control the SET and RESET process, respectively. Our new method is different from the traditional pulse operation in which both the width and height of program/erase pulse are simply kept constant which would lead to unnecessary damage to the device. In our new method, in each program or erase operation, a series of pulses with the width/height gradually increased are made use of to fully finish the SET/RESET switching but no excessive stress is generated at the same time, so width/height-controlled accurate SET/RESET can be achieved. Through the operation, the uniformity and endurance of the RRAM device has been significantly improved.

27 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
YZYanfei Zhang
Yanfei Zhang
KYKaiping Yuan
Kaiping Yuan
ZYZhaoan Yu
Zhaoan Yu
YZYunhan Zhang
Yunhan Zhang
XLXin Liu
Xin Liu
TLTieliang Lv
Tieliang Lv
The application of oxygen sensors based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) in the industrial field has received extensive attention. However, most of the existing studies construct detection systems using discrete devices, making it difficult to apply them in the industrial field. In this work, through the optimization of the sensor circuit, the size of the core components of the sensor is reduced to 7.8 × 7.8 × 11.8 cm3, integrating the laser, photodetector, and system control circuit. A novel integrated optical path design is proposed for the optical mechanical structure, which enhances the structural integration and long-term optical path stability while reducing the system assembly complexity. The interlocking design of the laser-driven digital-to-analog converter (DAC) and photocurrent acquisition analog-to-digital converter (ADC) reduces the requirements of the harmonic signal extraction for the system hardware. By adopting a high-precision ADC and a high-resolution pulse-width modulation (PWM), the peak-to-peak value of the laser temperature control noise is reduced to 2 m°C, thereby reducing the detection noise of the sensor. This oxygen detection system has a minimum response time of 0.1 s. Under the condition of a 0.5 m detection optical path, the Allan variance shows that when the integration time is 5.6 s, the detection limit reaches 53.4 ppm, which is ahead of the detection accuracy of similar equipment under the very small system size.

9 November 2026 in Photonics
Verified
Journal Article
Open access
PDF file
TLTao Liu
Tao Liu
ZYZhaoan Yu
Zhaoan Yu
KYKaiping Yuan
Kaiping Yuan
TLTieliang Lv
Tieliang Lv
Tunable diode laser absorption spectroscopy (TDLAS) has been widely applied in industrial gas detection, but traditional calibration methods face challenges including high standard gas consumption, exorbitant costs, and heavy calibration workloads—particularly under wide temperature and pressure ranges, where variations in laser parameters can introduce significant errors. This study proposes a simplified calibration method for peak-locking TDLAS systems based on wavelength modulation spectroscopy (WMS). First, a coupling relationship model between the modulation index (m) and amplitude modulation (AM) is established, and an iterative calibration method is developed to synchronously adjust the laser operating current and temperature, enabling both m = 2.2 and AM = 0.1 to converge to their target values simultaneously, thereby eliminating the need for per-device temperature–pressure–concentration ternary calibration. Subsequently, the effects of quadratic nonlinearity in the laser power–current (P-I) and wavenumber–current (v-I) curves on detection accuracy are systematically analyzed for both 2f/1f and 4f/1f WMS representation methods. The simulation results obtained within a temperature range of 300 K ± 100 K and a pressure range of 1 atm ± 0.2 atm show that, for 2f/1f-WMS, a v-I nonlinearity rate of ±5% yields a maximum detection error of no more than 0.11% (with the error peak occurring in the 40–65% concentration range and no zero offset), while a P-I nonlinearity rate of ±5% results in a maximum error of no more than 0.82%, nearly independent of concentration. By comparison, the 4f/1f-WMS scheme effectively suppresses the zero offset induced by P-I nonlinearity, achieves lower detection errors, and requires only span calibration for each device. The proposed method significantly reduces the calibration workload and cost of TDLAS systems while ensuring detection accuracy.