1 February 2012 in Respiratory Care
Verified
Journal Article
Closed access
EDEhab GAMIL Dawood
Ehab GAMIL Dawood
HFHany L Farag
Hany L Farag
RCRobert L Chatburn
Robert L Chatburn
Airway pressure release ventilation (APRV) is inverse ratio, pressure controlled, intermittent mandatory ventilation with unrestricted spontaneous breathing. It is based on the principle of open lung approach. It has many purported advantages over conventional ventilation, including alveolar recruitment, improved oxygenation, preservation of spontaneous breathing, improved hemodynamics, and potential lung-protective effects. It has many claimed disadvantages related to risks of volutrauma, increased work of breathing, and increased energy expenditure related to spontaneous breathing. APRV is used mainly as a rescue therapy for the difficult to oxygenate patients with acute respiratory distress syndrome (ARDS). There is confusion regarding this mode of ventilation, due to the different terminology used in the literature. APRV settings include the "P high," "T high," "P low," and "T low". Physicians and respiratory therapists should be aware of the different ways and the rationales for setting these variables on the ventilators. Also, they should be familiar with the differences between APRV, biphasic positive airway pressure (BIPAP), and other conventional and nonconventional modes of ventilation. There is no solid proof that APRV improves mortality; however, there are ongoing studies that may reveal further information about this mode of ventilation. This paper reviews the different methods proposed for APRV settings, and summarizes the different studies comparing APRV and BIPAP, and the potential benefits and pitfalls for APRV.

1 January 2007 in Annals of Thoracic Medicine
Verified
Journal Article
Open access
PDF file
EDEhab GAMIL Dawood
Ehab GAMIL Dawood
Airway pressure release ventilation was introduced to clinical practice about two decades ago as an alternative mode for mechanical ventilation; however, it had not gained popularity until recently as an effective safe alternative for difficult-to-oxygenate patients with acute lung injury/ acute respiratory distress syndrome This review will cover the definition and mechanism of airway pressure release ventilation, its advantages, indications, and guidance.

16 July 2019 in Respiratory Care
Verified
Journal Article
Closed access
EDEhab GAMIL Dawood
Ehab GAMIL Dawood
RKReynaldo Katigbak
Reynaldo Katigbak
MOMarcus Ottochian
Marcus Ottochian
BACKGROUND: New-generation ventilators display dynamic measures of respiratory mechanics, such as compliance, resistance, and auto-PEEP. Knowledge of the respiratory mechanics is paramount to clinicians at the bedside. These calculations are obtained automatically by using the least squares fitting method of the equation of motion. The accuracy of these calculations in static and dynamic conditions have not been fully validated or examined in different clinical conditions or various ventilator modes. METHODS: A bench study was performed by using a lung simulator to compare the ventilator automated calculations during passive and active conditions. Three clinical scenarios (normal, COPD, and ARDS) were simulated with known compliances and resistance set per respective condition: normal (compliance 50 mL/cm H 2 O, resistance 10 cm H 2 O/L/s), COPD (compliance 60 mL/cm H 2 O, resistance 22 cm H 2 O/L/s), and ARDS (compliance 30 mL/cm H 2 O, and resistance 13 cm H 2 O/L/s). Each scenario was subjected to 4 different muscle pressures (P mus ): 0, −5, −10, and −15 cm H 2 O. All the experiments were done using adaptive support ventilation. The resulting automated dynamic calculations of compliance and resistance were then compared based on the clinical scenarios. RESULTS: There was a small bias (average error) and level of agreement in the passive conditions in all the experiments; however, these errors and levels of agreement got progressively higher proportional to the increased P mus . There was a strong positive correlation between P mus and compliance measured as well as a strong negative correlation between P mus and resistance measured. CONCLUSIONS: Automated displayed calculations of respiratory mechanics were not dependable or accurate in active breathing conditions. The calculations were clinically more reliable in passive conditions. We propose different methods of calculating P mus , which, if incorporated into the calculations, would improve the accuracy of respiratory mechanics made via the least squares fitting method in actively breathing conditions.

1 March 2011 in Cleveland Clinic Journal of Medicine
Verified
Journal Article
Open access
PDF file
EDEhab GAMIL Dawood
Ehab GAMIL Dawood
ENEngi Nakhla
Engi Nakhla
RSReecha Sharma
Reecha Sharma


1 September 2020 in Journal of Mechanical Ventilation
Verified
Journal Article
Closed access
NHNatsumi Hamahata
Natsumi Hamahata
RSRyota Sato
Ryota Sato
KYKimiyo Yamasaki
Kimiyo Yamasaki
SPSophie Pereira
Sophie Pereira
EDEhab GAMIL Dawood
Ehab GAMIL Dawood
Background: Quantification of the patient’s respiratory effort during mechanical ventilation is very important, and calculating the actual muscle pressure (Pmus) during mechanical ventilation is a cumbersome task and usually requires an esophageal balloon manometry. Airway occlusion pressure at 100 milliseconds (P0.1) can easily be obtained non-invasively. There has been no study investigating the association between Pmus and P0.1. Therefore, we aimed to investigate whether P0.1 correlates to Pmus and can be used to estimate actual Pmus Materials and Methods: A bench study using lung simulator (ASL 5000) to simulate an active breathing patient with Pmus from 1 to 30 cmH2O by increments of 1 was conducted. Twenty active breaths were measured in each Pmus. The clinical scenario was constructed as a normal lung with a fixed setting of compliances of 60 mL/cmH2O and resistances of 10 cmH2O/l/sec. All experiments were conducted using the pressure support ventilation mode (PSV) on a Hamilton-G5 ventilator (Hamilton Medical AG, Switzerland), Puritan Bennett 840TM (Covidien-Nellcor, CA) and Avea (CareFusion, CA). Main results: There was significant correlation between P 0.1 and Pmus (correlation coefficient = - 0.992, 95% CI: - 0.995 to -0.988, P-value<0.001). The equation was calculated as follows: Pmus = -2.99 x (P0.1) + 0.53 Conclusion: Estimation of Pmus using P 0.1 as a substitute is feasible, available, and reliable. Estimation of Pmus has multiple implications, especially in weaning of mechanical ventilation, adjusting ventilator support, and calculating respiratory mechanics during invasive mechanical ventilation. Keywords: P 0.1, Inspiratory occlusion pressure, WOB, Esophageal balloon, mechanical ventilators, respiratory failure Keywords: P 0.1, P mus, Inspiratory occlusion pressure, WOB, Esophageal balloon, mechanical ventilators, respiratory failure