Eman M. Moaaz

Dr. Eman M. Moaaz

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2021 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
EMEman M. Moaaz
Eman M. Moaaz
AMAmr M. Mahmoud
Amr M. Mahmoud
AFAhmed S. Fayed
Ahmed S. Fayed
MRMamdouh R. Rezk
Mamdouh R. Rezk
EAEzzat M. Abdel‐Moety
Ezzat M. Abdel‐Moety

17 May 2022 in Electroanalysis
Verified
Journal Article
Closed access
AMAmr M. Mahmoud
Amr M. Mahmoud
EMEman M. Moaaz
Eman M. Moaaz
MRMamdouh R. Rezk
Mamdouh R. Rezk
EAEzzat M. Abdel‐Moety
Ezzat M. Abdel‐Moety
AFAhmed S. Fayed
Ahmed S. Fayed

28 June 2021 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Closed access
PDF file
EMEman M. Moaaz
Eman M. Moaaz
EAEzzat M Abdel-Moety
Ezzat M Abdel-Moety
MRMamdouh R Rezk
Mamdouh R Rezk
AFAhmed S Fayed
Ahmed S Fayed
Background: The green chemistry approach was developed for the purpose of saving the environment by using green solvents. Applying green analytical chemistry principles to traditional methods is considered a challenge. Acemetacin is a commonly used analgesic prodrug that bioactivates to indomethacin. Objective: Developing two simple, eco-friendly chromatographic methods for simultaneous determination of acemetacin and indomethacin. Method: The first method is HPLC-DAD. Separation was performed on a Waters XBridge® Shield RP18 (250 × 4.6 mm, 5 µm) analytical column with ethanol–ammonium acetate buffer (50 mM, pH 3.5 ± 0.1; 60:40, v/v) as a mobile phase at a flow rate of 1 mL/min at 25 ± 0.5°C and UV detection at 254 nm. The other method is TLC coupled with densitometric quantification using pre-coated silica TLC plates and butanol–ethyl acetate (70:30, v/v) elution system. The plates were scanned at 254 nm. Results: Both methods were validated according to International Conference on Harmonization guidelines. Linearity was confirmed for both over a concentration range of 1–100 µg/mL for the HPLC method and 0.2–7 µg/band for TLC-densitometric method. The methods’ greenness was evaluated by the National Environmental Methods Index, Eco-Scale, Green Analytical Procedure Index metrics and Analytical GREEnness Metric Approach. Conclusions: The proposed methods were found to be suitable for determination of studied drugs in their marketed formulations and is suggested for routine analysis in quality control laboratories. Highlights: The developed HPLC method shortened the elution time of the analyzed drugs saving more time and money and the TLC method lowered the drugs’ detection limit. HPLC and TLC methods were validated for the assay of acemetacin and indomethacin. The methods’ greenness was evaluated and compared to published methods. The developed HPLC method shortened the elution time of the analyzed drugs, saving time and money and the TLC method lowered the drugs’ detection limit.

29 May 2025 in RSC Advances
Verified
Journal Article
Open access
EMEman M. Moaaz
Eman M. Moaaz
AFAhmed S. Fayed
Ahmed S. Fayed
EAEzzat M. Abdel-Moety
Ezzat M. Abdel-Moety
MRMamdouh R. Rezk
Mamdouh R. Rezk
This work is overcoming the selectivity issue using the molecularly imprinted polymer (MIP) approach to determine donepezil (DON) and memantine (MEM) in their combined pharmaceutical formulation.

23 September 2024 in BMC Chemistry
Verified
Journal Article
Open access
PDF file
EMEman M. Moaaz
Eman M. Moaaz
EAEzzat M. Abdel-Moety
Ezzat M. Abdel-Moety
MRMamdouh R. Rezk
Mamdouh R. Rezk
AFAhmed S. Fayed
Ahmed S. Fayed
The rapid uprising technologies of smartphone applications and software introduced a new era for analytical detection techniques. It has transformed bench-top laboratory methods into simpler ones depending on cost-effective, portable, and widely accessible devices. In this work, two high performance thin layer chromatographic (HPTLC) methods were developed based on smartphone’s camera detection and either ImageJ desktop software or Color-Picker smartphone’s application as alternative techniques to conventional densitometric detection. A mixture of Naltrexone hydrochloride (NAL) and Bupropion hydrochloride (BUP) was chromatographed on HPTLC- plates using ethyl acetate, methanol, acetone, and glacial acetic acid (3:6:1:0.5, by volume) as a developing system. The developed plates were scanned at 203 nm for the densitometric analysis, then visualized by modified Dragendorff’s reagent and shot by a smartphone’s camera. The captured images were uploaded to either ImageJ software or Color-Picker application to detect the separated spots. The results derived from the three detection methods were compared over the concentration range of 0.4–24 & 0.6–18 µg/band for the densitometric method, 0.4–24 & 2–24 µg/band for ImageJ built method and 0.8–20 & 5–20 µg/band for Color Picker built method for NAL and BUP, respectively. The methods were found to be appropriate for assaying both active drug substances in pure forms and combined in marketed pharmaceutical formulations. The excellent sustainability of densitometric and ImageJ-based methods enabled also the assessment of their dosage form content uniformity. The greenness and sustainability of the methods were assessed by three metric tools, namely Green Analytical Procedure Index (GAPI), Analytical GREEnness Metric Approach (AGREE), and White Analytical Chemistry (WAC). The assessments results confirmed the sustainability and superiority of the proposed methods in terms of sample treatment, waste mount, energy consumption, cost, and number of analyzed samples per an hour.

1 February 2025 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
EMEman M. Moaaz
Eman M. Moaaz
AFAhmed S. Fayed
Ahmed S. Fayed
EAEzzat M. Abdel-Moety
Ezzat M. Abdel-Moety
MRMamdouh R. Rezk
Mamdouh R. Rezk
Substantial preference for target analytes was attained by molecularly-imprinted polymers (MIPs). A novel indirect voltammetric technique was developed to provide a useful gate for the analysis of electro-inactive substances through selective interaction with MIP and hence decrease of redox-active probe signal at the electrode’s surface. In this work, a methyldopa-based MIP was fabricated for the selective binding with memantine (MEM), a voltammetry-inactive and widely used drug for Alzheimer’s disease. In-situ electropolymerization of methyldopa monomer was implemented onto a pencil graphite electrode using MEM as a template in phosphate buffer pH 7.0. The monomer-template interaction was evaluated by UV-spectroscopy. The modified surface of the electrode was characterized using scanning electron microscope and X-ray photoelectron spectroscopy. The functionality of the sensor was assessed using cyclic voltammetry and electrochemical impedance analysis. The response was linear over a concentration range of 1.0 × 10–12 to 1.0 × 10−10 M with a detection limit down to 1.5 × 10−13 M. Sensor selectivity was studied using the co-formulated drug, donepezil. The MIP-sensor exhibited high sensitivity and proper selectivity, allowing its applicability for the analysis of MEM in combined formulations and in spiked human plasma samples. The overall process was subjected to a greenness and whiteness assessment, confirming its eco-friendliness and sustainability.