Thijs Vandenryt

Mr. Thijs Vandenryt

Hasselt University, Belgium
+1
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
MKMarie Krecmarova
Marie Krecmarova
MGMichal Gulka
Michal Gulka
TVThijs Vandenryt
Thijs Vandenryt
JHJaroslav Hrubý
Jaroslav Hrubý
LFLadislav Fekete
Ladislav Fekete
MNMiloš Nesládek
Miloš Nesládek
We propose a label-free biosensor concept based on the charge state manipulation of nitrogen-vacancy (NV) quantum color centers in diamond, combined with an electrochemical microfluidic flow cell sensor, constructed on boron-doped diamond. This device can be set at a defined electrochemical potential, locking onto the particular chemical reaction, whilst the NV center provides the sensing function. The NV charge state occupation is initially prepared by applying a bias voltage on a gate electrode and then subsequently altered by exposure to detected charged molecules. We demonstrate the functionality of the device by performing label-free optical detection of DNA molecules. In this experiment, a monolayer of strongly cationic charged polymer polyethylenimine is used to shift the charge state of near surface NV centers from negatively charged NV– to neutral NV0 or dark positively charged NV+. Immobilization of negatively charged DNA molecules on the surface of the sensor restores the NV centers charge state back to the negatively charged NV–, which is detected using confocal photoluminescence microscopy. Biochemical reactions in the microfluidic channel are characterized by electrochemical impedance spectroscopy. The use of the developed electrochemical device can also be extended to nuclear magnetic resonance spin sensing.

20 June 2014 in Sensors
Verified
Journal Article
Open access
PDF file
GWGideon Wackers
Gideon Wackers
TVThijs Vandenryt
Thijs Vandenryt
PCPeter Cornelis
Peter Cornelis
EKEvelien Kellens
Evelien Kellens
Ronald ThoelenRonald Thoelen
Ronald Thoelen
PWPatrick Wagner
Patrick Wagner
In this work we present the first steps towards a molecularly imprinted polymer (MIP)-based biomimetic sensor array for the detection of small organic molecules via the heat-transfer method (HTM). HTM relies on the change in thermal resistance upon binding of the target molecule to the MIP-type receptor. A flow-through sensor cell was developed, which is segmented into four quadrants with a volume of 2.5 μL each, allowing four measurements to be done simultaneously on a single substrate. Verification measurements were conducted, in which all quadrants received a uniform treatment and all four channels exhibited a similar response. Subsequently, measurements were performed in quadrants, which were functionalized with different MIP particles. Each of these quadrants was exposed to the same buffer solution, spiked with different molecules, according to the MIP under analysis. With the flow cell design we could discriminate between similar small organic molecules and observed no significant cross-selectivity. Therefore, the MIP array sensor platform with HTM as a readout technique, has the potential to become a low-cost analysis tool for bioanalytical applications.

23 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
TVThijs Vandenryt
Thijs Vandenryt
BGBart Van Grinsven
Bart Van Grinsven
KEKasper Eersels
Kasper Eersels
PCPeter Cornelis
Peter Cornelis
SKSafira Kholwadia
Safira Kholwadia
PWPatrick Wagner
Patrick Wagner
Serotonin is an important neurotransmitter that plays a major role in the pathogenesis of a variety of conditions, including psychiatric disorders. The detection of serotonin typically relies on high-performance liquid chromatography (HPLC), an expensive technique that requires sophisticated equipment and trained personnel, and is not suitable for point-of-care applications. In this contribution, we introduce a novel sensor platform that can measure spiked neurotransmitter concentrations in whole blood samples in a fast and low-cost manner by combining synthetic receptors with a thermal readout technique—the heat-transfer method. In addition, the design of a miniaturized version of the sensing platform is presented that aims to bridge the gap between measurements in a laboratory setting and point-of-care measurements. This fully automated and integrated, user-friendly design features a capillary pumping unit that is compatible with point-of-care sampling techniques such as a blood lancet device (sample volume—between 50 µL and 300 µL). Sample pre-treatment is limited to the addition of an anti-coagulant. With this fully integrated setup, it is possible to successfully discriminate serotonin from a competitor neurotransmitter (histamine) in whole blood samples. This is the first demonstration of a point-of-care ready device based on synthetic receptors for the screening of neurotransmitters in complex matrices, illustrating the sensor’s potential application in clinical research and diagnosis of e.g., early stage depression.

6 January 2022 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
Gilles OudebrouckxGilles Oudebrouckx
Gilles Oudebrouckx
JGJuul Goossens
Juul Goossens
SBSeppe Bormans
Seppe Bormans
TVThijs Vandenryt
Thijs Vandenryt
PWPatrick Wagner
Patrick Wagner
Ronald ThoelenRonald Thoelen
Ronald Thoelen

1 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SBSeppe Bormans
Seppe Bormans
Gilles OudebrouckxGilles Oudebrouckx
Gilles Oudebrouckx
PVPatrick Vandormael
Patrick Vandormael
TVThijs Vandenryt
Thijs Vandenryt
PWPatrick Wagner
Patrick Wagner
Ronald ThoelenRonald Thoelen
Ronald Thoelen
The study of cell proliferation is of great importance for medical and biological research, as well as for industrial applications. To render the proliferation process accurately over time, real-time cell proliferation assay methods are required. This work presents a novel real-time and label-free approach for monitoring cell proliferation by continuously measuring changes in thermal properties that occur at the sensor interface during the process. The sensor consists of a single planar resistive structure deposited on a thin foil substrate, integrated at the bottom of a cell culture reservoir. During measurement, the structure is excited with square wave current pulses. Meanwhile, the temperature-induced voltage change measured over the structure is used to derive variations in the number of cells at the interface. This principle is demonstrated first by performing cell sedimentation measurements to quantify the presence of cells at the sensor interface in the absence of cell growth. Later, cell proliferation experiments were performed, whereby parameters such as the available nutrient content and the cell starting concentration were modified. Results from these experiments show that the thermal-based sensor is able to accurately measure variations in the number of cells at the interface. Moreover, the influence of the modified parameters could be observed in the obtained proliferation curves. These findings highlight the potential for the presented thermal method to be incorporated in a standardized well plate format for high-throughput monitoring of cell proliferation.

23 October 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Gilles OudebrouckxGilles Oudebrouckx
Gilles Oudebrouckx
TVThijs Vandenryt
Thijs Vandenryt
PNPhilippe Nivelle
Philippe Nivelle
SBSeppe Bormans
Seppe Bormans
PWPatrick Wagner
Patrick Wagner
Ronald ThoelenRonald Thoelen
Ronald Thoelen
In many sensing applications, ranging from processes monitoring to bioassays, interactions occur between a thin film and a liquid medium. For such applications, it is generally crucial to monitor physical changes in the film over time. Consequently, the demand for sensitive, yet robust readout methods that can be used to do so is high. In this article, we present a new, thermal-based readout principle that can be applied to monitor physical changes in thin samples over time. This new Transient Thermal Offset (TTO) method is derived from the widely used Transient Plane Source (TPS) method, but intentionally deviates from the condition to not apply thermal pulses that probe deeper than the boundaries of the thin sample. By doing so, it is possible to use the properties of the sample on top of the film as a reference with the novel data processing method. The sensing principle was first demonstrated via numerical simulations in COMSOL Multiphysics. software. Then, for experimental validation, we performed TTO measurements to monitor the removal process of a thin film over time. The results show that the TTO method can be used reliably in practice for monitoring physical changes in thin films. Since also the properties of the surrounding material are measured, it is possible to distinguish between changes in the thin film and changes in the direct environment.