Fire risk analysis models utilized for the fire risk assessment of domestic structures do not usually take into account flame spread and building size. Therefore, in this study, the effect of the building size on flame spread was investigated. Results showed that the frequency of occurrence of fires increased when the building has 11 or more floors. Additionally, the rate of occurrence of small-scale fires also increased when the total floor area was greater than or equal to 1,000 m2. From the risk analysis, the fire risk of health care, medical, and recreational facilities were calculated to be 25.7 × 10-3, 4.29 × 10-3, and 0.91 × 10-3 persons per year, respectively. As such, these were classified as high-risk facilities.
28 February 2021 in Journal of the Korean Society of Hazard Mitigation
This study has developed a model that predicts casualties (dead and injured people) using the Classification And Regression Tree (CART). Based on the fire statistics collected over a decade, this model aims to select the appropriate risk-assessment scenarios and fire prevention and safety methods applicable on individual buildings. Our evaluation indicates that this CART model can accurately predict 48 scenarios based on 5 variables related to the types of fire, fire growth rates, and evacuation situations, and calculate the corresponding probabilities for each occurrence. This model is expected to improve future quantitative fire risk assessments.
28 February 2021 in Journal of the Korean Society of Hazard Mitigation
There are approximately 290 million blind people worldwide. Among them, approximately 40 million people are severely blind. Although systems and policies have been improved to enhance the convenience of the visually impaired, the standards related to evacuation safety in the case of fire have not been sufficiently improved. Therefore, in this study, to ensure the safe evacuation of the visually impaired in case of fire, domestic fire safety standards were derived by analyzing the development status of a domestic barrier-free system and related manuals based on the characteristics of evacuation behaviors of the visually impaired, as well as by reviewing the cases in the United States and the United Kingdom. As a result, the following measures were derived: 1) improving the display method for landmark elements, 2) customized fire safety education and training for employees, and 3) a plan to develop a personal emergency evacuation planning manual in accordance with the characteristics of a building. It is expected that these objectives can be used to improve fire safety standards and manuals and to develop related technologies for the visually impaired.
31 December 2019 in Journal of the Korean Society of Hazard Mitigation