Alistair Curd

Dr. Alistair Curd

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2017 in eLife
Verified
Journal Article
Open access
CTChristian Tiede
Christian Tiede
RBRobert Bedford
Robert Bedford
SHSophie J Heseltine
Sophie J Heseltine
GSGina Smith
Gina Smith
IWImeshi Wijetunga
Imeshi Wijetunga
DTDarren Charles Tomlinson
Darren Charles Tomlinson
Molecular recognition reagents are key tools for understanding biological processes and are used universally by scientists to study protein expression, localisation and interactions. Antibodies remain the most widely used of such reagents and many show excellent performance, although some are poorly characterised or have stability or batch variability issues, supporting the use of alternative binding proteins as complementary reagents for many applications. Here we report on the use of Affimer proteins as research reagents. We selected 12 diverse molecular targets for Affimer selection to exemplify their use in common molecular and cellular applications including the (a) selection against various target molecules; (b) modulation of protein function in vitro and in vivo; (c) labelling of tumour antigens in mouse models; and (d) use in affinity fluorescence and super-resolution microscopy. This work shows that Affimer proteins, as is the case for other alternative binding scaffolds, represent complementary affinity reagents to antibodies for various molecular and cell biology applications.

23 November 2015 in Nature Cell Biology
Verified
Journal Article
Closed access
PDF file
NLNils J. Lambacher
Nils J. Lambacher
ABAnge-Line Bruel
Ange-Line Bruel
TDTeunis J. P. van Dam
Teunis J. P. van Dam
KSKatarzyna Szymańska
Katarzyna Szymańska
GSGisela G. Slaats
Gisela G. Slaats
Oliver E BlacqueOliver E Blacque
Oliver E Blacque

1 April 2023 in Communications Biology
Verified
Journal Article
Open access
PDF file
ECEulashini Chuntharpursat-Bon
Eulashini Chuntharpursat-Bon
OPOleksandr V. Povstyan
Oleksandr V. Povstyan
MLMelanie J. Ludlow
Melanie J. Ludlow
DCDavid J. Carrier
David J. Carrier
MDMarjolaine Debant
Marjolaine Debant
DBDavid John Beech
David John Beech
Two prominent concepts for the sensing of shear stress by endothelium are the PIEZO1 channel as a mediator of mechanically activated calcium ion entry and the PECAM1 cell adhesion molecule as the apex of a triad with CDH5 and VGFR2. Here, we investigated if there is a relationship. By inserting a non-disruptive tag in native PIEZO1 of mice, we reveal in situ overlap of PIEZO1 with PECAM1. Through reconstitution and high resolution microscopy studies we show that PECAM1 interacts with PIEZO1 and directs it to cell-cell junctions. PECAM1 extracellular N-terminus is critical in this, but a C-terminal intracellular domain linked to shear stress also contributes. CDH5 similarly drives PIEZO1 to junctions but unlike PECAM1 its interaction with PIEZO1 is dynamic, increasing with shear stress. PIEZO1 does not interact with VGFR2. PIEZO1 is required in Ca2+-dependent formation of adherens junctions and associated cytoskeleton, consistent with it conferring force-dependent Ca2+ entry for junctional remodelling. The data suggest a pool of PIEZO1 at cell junctions, the coming together of PIEZO1 and PECAM1 mechanisms and intimate cooperation of PIEZO1 and adhesion molecules in tailoring junctional structure to mechanical requirement.

15 July 2018 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
TSThomas Schlichthaerle
Thomas Schlichthaerle
AEAlexandra S. Eklund
Alexandra S. Eklund
FSFlorian Schueder
Florian Schueder
MSMaximilian T. Strauss
Maximilian T. Strauss
CTChristian Tiede
Christian Tiede
RJRalf Jungmann
Ralf Jungmann

1 October 2015 in Methods
Verified
Journal Article
Open access
ACAlistair Curd
Alistair Curd
ACAlexa Cleasby
Alexa Cleasby
KMKatarzyna Makowska
Katarzyna Makowska
AYAndrew York
Andrew York
HSHari Shroff
Hari Shroff
MPMichelle Peckham
Michelle Peckham
A challenge in biological imaging is to capture high-resolution images at fast frame rates in live cells. The "instant structured illumination microscope" (iSIM) is a system designed for this purpose. Similarly to standard structured illumination microscopy (SIM), an iSIM provides a twofold improvement over widefield microscopy, in x, y and z, but also allows much faster image acquisition, with real-time display of super-resolution images. The assembly of an iSIM is reasonably complex, involving the combination and alignment of many optical components, including three micro-optics arrays (two lenslet arrays and an array of pinholes, all with a pitch of 222 μm) and a double-sided scanning mirror. In addition, a number of electronic components must be correctly controlled. Construction of the system is therefore not trivial, but is highly desirable, particularly for live-cell imaging. We report, and provide instructions for, the construction of an iSIM, including minor modifications to a previous design in both hardware and software. The final instrument allows us to rapidly acquire fluorescence images at rates faster than 100 fps, with approximately twofold improvement in resolution in both x-y and z; sub-diffractive biological features have an apparent size (full width at half maximum) of 145 nm (lateral) and 320 nm (axial), using a 1.49 NA objective and 488 nm excitation.

27 July 2017 in Biophysical Reviews
Verified
Journal Article
Open access
PDF file
RBR. Bedford
R. Bedford
CTC. Tiede
C. Tiede
RHR. Hughes
R. Hughes
ACAlistair Curd
Alistair Curd
MMM. J. McPherson
M. J. McPherson
DTDarren Charles Tomlinson
Darren Charles Tomlinson
Antibodies have been indispensable tools in molecular biology, biochemistry and medical research. However, a number of issues surrounding validation, specificity and batch variation of commercially available antibodies have prompted research groups to develop novel non-antibody binding reagents. The ability to select highly specific monoclonal non-antibody binding proteins without the need for animals, the ease of production and the ability to site-directly label has enabled a wide variety of applications to be tested, including imaging. In this review, we discuss the success of a number of non-antibody reagents in imaging applications, including the recently reported Affimer.