Marco Tosi

Dr. Marco Tosi

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2025 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
DNDavide Negrini
Davide Negrini
LPLaura Pighi
Laura Pighi
MTMarco Tosi
Marco Tosi
Giuseppe LippiGiuseppe Lippi
Giuseppe Lippi
Article Evaluating the accuracy of ChatGPT in classifying normal and abnormal blood cell morphology was published on January 10, 2025 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 0, issue 0).

12 July 2024 in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
Verified
Journal Article
Open access
PDF file
MTMarco Tosi
Marco Tosi
DNDavide Negrini
Davide Negrini
GCGiovanni Celegon
Giovanni Celegon
Martina MontagnanaMartina Montagnana
Martina Montagnana
Giuseppe LippiGiuseppe Lippi
Giuseppe Lippi
Objectives: Urinalysis is widely used and is also frequently requested in emergency situations for screening hypovolemia, urinary tract infections, diabetes, ketoacidosis and hematuria. Our aim was to evaluate the impact of reporting urinary sediment in emergency department specimens with the Sysmex UN system. Methods: We evaluated urinalyses requested by the emergency department over a three-month period and examined red blood cell count interference, compared leukocyte esterase dipsticks to cytofluorimetric leukocyte count and nitrites to cytofluorimetric bacterial count. We then examined digital microscopy images to identify additional elements of interest or pathology. Results: We collected 532 cases, 354 with only chemical and cytofluorimetric analysis and 178 with digital microscopy. Automated erythrocyte counting showed a 7 % error rate, mainly false-positive results. Leukocyte esterase had a sensitivity of 88.22 % and specificity of 88.84 % at the lower limit, while nitrites had a sensitivity of 41.06 % and a specificity of 99.38 %. Pathological elements were detected in 126 samples by digital microscopy: 70 had casts, 36 crystals and seven cells with high pathological value. Conclusions: Evaluation of urine sediments by trained specialists can provide potentially important information even in emergency situations, whereby the pre-analytical phase must always be taken into account.

23 September 2024 in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
Verified
Journal Article
Open access
PDF file
MTMarco Tosi
Marco Tosi
DNDavide Negrini
Davide Negrini
GCGiovanni Celegon
Giovanni Celegon
Martina MontagnanaMartina Montagnana
Martina Montagnana
Giuseppe LippiGiuseppe Lippi
Giuseppe Lippi
Resumen: Objetivos: El análisis de orina es ampliamente utilizado y frecuentemente solicitado desde los servicios de urgencias para evaluar la presencia de hipovolemia, infecciones del tracto urinario, diabetes, cetoacidosis y hematuria. Nuestro objetivo era evaluar el impacto de informar el sedimento urinario en muestras enviadas desde el servicio de urgencias utilizando el analizador Sysmex ® Serie-UN. Métodos: Evaluamos los análisis de orina solicitados por el servicio de urgencias durante un periodo de tres meses e investigamos la interferencia del recuento de hematíes, comparamos las tiras reactivas de esterasa leucocitaria con el recuento de leucocitos citofluorimétrico y los nitritos con el recuento bacteriano citofluorimétrico. A continuación, examinamos las imágenes con el microscopio digital para identificar otros posibles elementos o patologías de interés. Resultados: Recopilamos 532 casos, en 354 de los cuales solo se disponía de análisis bioquímico y citofluorimetríco, y en 178 se disponía además de análisis por microscopía digital. El recuento automatizado de eritrocitos mostró una tasa de error del 7 %, principalmente falsos positivos. La esterasa leucocitaria tuvo una sensibilidad del 88,22 % y una especificidad del 88,84 % en el límite inferior, mientras que los nitritos tuvieron una sensibilidad del 41,06 % y una especificidad del 99,38 %. Se detectaron elementos patológicos en 126 muestras mediante microscopía digital, de los cuales 70 presentaban cilindros, 36 cristales y 7 contenían células de elevado valor patológico. Conclusiones: La evaluación de los sedimentos en orina por parte de especialistas capacitados puede aportar información potencialmente relevante incluso en casos urgentes, donde la fase preanalítica debe ser siempre tenida en cuenta.

5 September 2023 in Diagnosis
Verified
Journal Article
Closed access
Giuseppe LippiGiuseppe Lippi
Giuseppe Lippi
LPLaura Pighi
Laura Pighi
MTMarco Tosi
Marco Tosi
MVMarco Vettori
Marco Vettori
GCGiovanni Celegon
Giovanni Celegon
GSGian Luca Salvagno
Gian Luca Salvagno
Objectives: There is limited information on the influence of collecting small amounts of blood on the quality of blood gas analysis. Therefore, the purpose of this study was to investigate the effects of different degrees of underfilling of syringes on test results of venous blood gas analysis. Methods: Venous blood was collected by venipuncture from 19 healthcare workers in three 1.0 mL syringes for blood gas analysis, by manually aspirating different volumes of blood (i.e., 1.0, 0.5 and 0.25 mL). Routine blood gas analysis was then immediately performed with GEM Premier 5,000. The results of the two underfilled syringes were compared with those of the reference syringe filled with appropriate blood volume. Results: The values of most assayed parameters did not differ significantly in the two underfilled syringes. Statistically significant variations were found for lactate, hematocrit and total hemoglobin, the values of which gradually increased as the fill volume diminished, as well as for sodium concentration, which decreased in both insufficiently filled blood gas syringes. The bias was clinically meaningful for lactate in syringe filled with 0.25 mL of blood, and for hematocrit, total hemoglobin and sodium in both syringes containing 0.5 and 0.25 mL of blood. Conclusions: Collection of smaller volumes of venous blood than the specified filling volume in blood gas syringes may have an effect on the quality of some test results, namely lactate, hematocrit, total hemoglobin and sodium. Specific indications must be given for standardizing the volume of blood to be collected within these syringes.

17 February 2026 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
PDF file
MTMarco Tosi
Marco Tosi
LPLaura Pighi
Laura Pighi
CCClaudia Lo Cascio
Claudia Lo Cascio
FMFilippo Marcazzan
Filippo Marcazzan
MRMariateresa Rizza
Mariateresa Rizza
Giuseppe LippiGiuseppe Lippi
Giuseppe Lippi
Objectives: The acute coronary syndrome (ACS) is a leading cause of morbidity and mortality worldwide, with timely diagnosis being critical for improving outcomes. Since high-sensitivity cardiac troponin (hs-cTn) assays have become the gold standard for detecting myocardial injury, this study aimed to evaluate the analytical performance of the novel Roche Elecsys TnT hs Gen 6 (TNT6ST) immunoassay. Methods: The TNT6ST immunoassay was assessed for intra- and inter-assay imprecision, linearity, limit of blank (LoB), limit of detection (LoD), functional sensitivity, and 99th percentile upper reference limit (URL). Comparisons were made with the previous Elecsys hs-cTnT immunoassay (TNTHSSTX). Hemolysis interference was evaluated in plasma samples with serially induced hemolysis. Results: TNT6ST exhibited excellent precision (intra-assay CV 0.8–2.0 %, inter-assay 1.5–2.4 %), linearity (r=1.00), LoB of 0.939 ng/L, LoD of 1.201 ng/L, and functional sensitivity of 1.255 ng/L. The 99th percentile URL was 20.9 ng/L overall, 30.5 ng/L in males, and 13.7 ng/L in females. Comparison with TNTHSSTX showed strong correlation (r=0.995) but a systematic bias, with TNT6ST overestimating cTnT by around 66 %. Hemolysis decreased cTnT values in both assays, but TNT6ST remained within the allowable total error, while TNTHSSTX exceeded this threshold at higher hemolysis levels. Conclusions: The novel Roche TNT6ST immunoassay demonstrates superior precision, sensitivity, and robustness to hemolysis compared with its predecessor, with excellent correlation across a wide cTnT range, supporting its reliability for introduction into routine clinical practice.

3 April 2025 in Scandinavian Journal of Clinical and Laboratory Investigation
Verified
Journal Article
Closed access
LPLaura Pighi
Laura Pighi
DNDavide Negrini
Davide Negrini
MTMarco Tosi
Marco Tosi
Giuseppe LippiGiuseppe Lippi
Giuseppe Lippi