Emre Kara

Dr. Emre Kara


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2010 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
EKEmre Kara
Emre Kara
AKA.İ. Kutlar
A.İ. Kutlar
Computational fluid dynamics (CFD) modelling based on a commercial package, FLUENT, has been used in the present study. The primary aim of this study is to develop a novel implant by employing CFD techniques. Firstly, CFD analyses on the best design commercially available, which is the Ahmed Glaucoma Valve (AGV®), are accomplished. In the light of the results, the new design focus is selected as the valve. The new design is analysed using GAMBIT and FLUENT software. CFD analyses of the new design and the AGV® are compared and the strengths of the new design are revealed. The results are also compared with the experimental studies AGV® in the literature. It is deduced that the proposed model shows a nonlinear pressure drop response, which is quite similar to that of AGV®. The optimum combination would be a flow rate of 2.5 μl/min and a pressure drop of 1054.58 Pa for the proposed model.

1 October 2023 in Journal of Applied Fluid Mechanics
Verified
Journal Article
Open access
PDF file
EKEmre Kara
Emre Kara
DKD. F. Kurtuluş
D. F. Kurtuluş
In the realm of aviation, jet propulsion systems serve to provide enhanced maneuverability and to make sure that the aircraft thrust is accurately and precisely regulated during take-off and landing operations. The movement of aerodynamic control surfaces (flaps, slats, elevators, ailerons, spoilers, wing attachments) determines the mobility of practically all aircraft types. Recognized as dependable components in the aviation world for take-off and landing tasks, these control surfaces are being replaced by fluidic thrust vectoring (FTV) systems, especially in small unmanned aerial vehicles (UAVs) and short or vertical take-off and landing aircraft. The FTV system is capable of directing thrust in any preferred direction without the need for any movable components. This paper numerically examines the FTV system by utilizing computational fluid dynamics (CFD) and an optimization technique based on gradients of the system components to understand the physics of the Coanda effect in FTV systems. This research employs gradient-based optimization for nozzle design in order to optimize the parameter space for different velocity ratios (VR) by calculating the moment around the upper Coanda surface, which is used to represent the jet deflection angle. In that context, four different Coanda surface-pintle pair designs for four different VRs are produced. The parameter space shows significant improvement in all four configurations, and results reveal that all output parameters successfully delay separation on the thrust vectoring system's upper Coanda surface. Finally, four optimum design suggestions are tested at various VRs, and the most efficient and proper design is recommended based on output parameters.

15 April 2021 in International Advanced Researches and Engineering Journal
Verified
Journal Article
Open access
PDF file
EKEmre Kara
Emre Kara
HEHüdai Erpulat
Hüdai Erpulat
In this study, a popular co-flow thrust vectoring system, which is superior to typical Coanda nozzles with one main jet, is examined experimentally and compared with 2D and 3D computational fluid dynamics results. High Speed Orienting Momentum with Enhanced Reversibility nozzle concept is the base design to proposed configuration which uses a control jet additional to the main jet for better and active enhancement on the flow vectoring and streamlined side-walls resulted in less flow blockage. This comparatively novel concept is utilized in an experimental setup to direct the thrust of aerial vehicles. The system includes two inlets (inlet1, inlet2) with different jet velocities and one pintle to separate and smoothly direct these jets and a converging-diverging nozzle to enclose these components. Experimental study is accomplished with four different configurations of inlet1 and inlet2 as 15 m/s and 10 m/s; 20 m/s and 10 m/s; 30 m/s and 10 m/s, and 45 m/s and 10 m/s, respectively. The tangential velocities on the curved surfaces are successfully measured utilizing a micro-manometer (Pitot tube) so that attachments/detachments of jets on the exit walls and deflection angles are calculated for each inlet velocities. The current experimental study also revealed that 3D assumption of computational fluid dynamics of Coanda effect is highly accurate and deflection angle results are not far from experimental results with the average deficit of only 5.44 %. As the result, 3D verification study resembles to experimental study in terms of deflection angles for all configurations.

21 October 2021 in Current Eye Research
Verified
Journal Article
Closed access
EKEmre Kara
Emre Kara
STSinan Turhan
Sinan Turhan
AKAhmet İhSan Kutlar
Ahmet İhSan Kutlar
KGKıvanç Güngör
Kıvanç Güngör
Researchers have investigated glaucoma drainage devices in various in vitro experimental setups to overcome their disadvantages. In this study, it is aimed to perform in vitro analyses of glaucoma ...

30 December 2024 in International Journal of Turbo & Jet-Engines
Verified
Journal Article
Closed access
EKEmre Kara
Emre Kara
DKDilek Funda Kurtuluş
Dilek Funda Kurtuluş
In this study, parametric optimization is employed to identify optimal output parameters for physical components of HOMER nozzle type fluidic thrust vectoring (FTV) system. Optimization study is conducted on seven output parameters: moment around upper Coanda surface, MA; performance parameter, PP; thrust vectoring angle, θ T; total thrust, T; thrust vectoring efficiency, η; axial thrust, Tx; transverse thrust, Ty. 440 case studies in design-of-experiment stage are employed, utilizing a range of meta-models. Genetic-Aggregation meta-model exhibited highest coefficient of determination (R2) among tested meta-models. In response surface optimization stage, six objectives are enforced through use of Multi-Objective-Genetic-Algorithm technique. Subsequently, three optimization candidate points are identified for filtering of output parameters deemed to be of particular importance. Among them, candidate point with geometry-4 and parameter-1 = 39.23 m/s, exhibited the highest values for PP, θ T, η, and Ty, with 4.78 %, 4.48 %, 7.97 %, and 7.94 % higher values, respectively, compared to the baseline geometry.

1 September 2019 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
EKEmre Kara
Emre Kara
AKAhmet İhSan Kutlar
Ahmet İhSan Kutlar
KGKıvanç Güngör
Kıvanç Güngör
Glaucoma is an eye disorder in which the optic nerve is damaged over time due to a sustained elevation of the intraocular pressure (IOP). Being the second leading cause of blindness according to the reports of the World Health Organization, glaucoma is not only a serious ocular disease that threatens individuals, but also a community health problem. In recent years, great improvement has been achieved in the technology of implants used in the treatment of the disease. Despite the great effort dedicated to the design and implementation of the glaucoma drainage devices (GDD), they still have unsolved problems and weaknesses. Most of the currently employed GDDs are very simple and have major problems such as reversed flow, choking and a coarse interval of pressure control. Experiments must be devised to investigate the flow behavior inside these devices. In this study, an accurate microfluidics experimental setup is constructed to analyze and characterize the in-vitro performance of actively employed GDDs on the glaucoma treatment. Proposed setup includes a pressurized fluid reservoir, ELVEFLOW microfluidics flow rate measurement/control unit, microfluidics flow/pressure sensors, and data analysis system. In the setup, more precise measurements than experimental setups in literature is planned to be provided. It is estimated that the results showing consistency with in-vivo measurements will be obtained, behavior of the fluid passing through the GDDs will be observed and issues with design flaws will be addressed.