Mahnoor Ali

Ms. Mahnoor Ali


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SAShoukat Ali Arain
Shoukat Ali Arain
Abdullah Al hawilAbdullah Al hawil
Abdullah Al hawil
SAShahid Akhund
Shahid Akhund
MAMahnoor Ali
Mahnoor Ali
SASalman Mohammed Aldosari
Salman Mohammed Aldosari
ABAbdulwahab Zaid Binjomah
Abdulwahab Zaid Binjomah
Objectives: Aggregate pre-analytical rejection rates conflate specimen-quality failures and administrative events, which require distinct mitigation protocols. We disaggregated rejection events to isolate specimen-quality failures and benchmarked them against global frameworks. Methods: We conducted a 25-month retrospective audit (July 2023 to August 2025) of test orders received by the Al Rass General Hospital laboratory. Using an AI-assisted classification protocol, we isolated pre-analytical Specimen Quality Failures from operational and administrative events. We mapped Specimen Quality Failure causes into IFCC WG-LEPS Quality Indicators (QIs) and evaluated via Six Sigma metrics, IFCC benchmarks, and Pareto analysis—stratified by laboratory section, sample type, priority, and work shift. Results: Of 905,018 test orders received, 35,476 were rejected (overall rejection rate 3.92%). However, the specimen-quality failures were 2.21% (σ = 3.51), with 15,495 entries excluded as operational events. Clotted samples (26.2%), hemolysis (23.0%), wrong sample type (20.2%), sample not received (7.8%), and insufficient volume (7.1%) together accounted for 84.3% of specimen quality failures (the Vital Few). Most individual categories scored Good (≥4.0) on Sigma, despite a pooled Sigma of 3.51 (Acceptable). Benchmarking against IFCC WG-LEPS targets showed that 6 of 13 quality indicators, including clotted sample, wrong sample type, and insufficient volume, fell Below Minimum, demonstrating divergent absolute internal process capability metrics and population-relative external benchmark performance signals. STAT samples had a lower specimen quality failure rate than Routine samples (1.25% vs. 2.51%). Although the morning shift accounted for 80.98% of total rejections, only 53.4% represented true specimen quality failures. Conclusions: Headline laboratory rejection rates are inflated by operational and administrative events, necessitating partitioned reporting models. While individual Westgard Sigma scores demonstrate satisfactory absolute process capability across most specimen quality failure categories, cross-referencing against population-relative IFCC targets contextualizes these results and identifies areas performing in the lower international quartiles. Quality improvement strategies require structural changes and workforce training.