John Mark O Leary

Mr. John Mark O Leary

Veterinary Medicine, University College Dublin (UCD), Dublin, Ireland
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2011 in Equine Veterinary Education
Verified
Journal Article
Closed access
PDF file
John Mark O LearyJohn Mark O Leary
John Mark O Leary
PDP. M. Dixon
P. M. Dixon

29 January 2013 in Equine Veterinary Journal
Verified
Journal Article
Closed access
PDF file
TBT. P. Barnett
T. P. Barnett
John Mark O LearyJohn Mark O Leary
John Mark O Leary
TPT. D. H. Parkin
T. D. H. Parkin
PDP. M. Dixon
P. M. Dixon
SBS. Z. Barakzai
S. Z. Barakzai

1 April 2013 in Veterinary Surgery
Verified
Journal Article
Closed access
PDF file
TBTimothy P. Barnett
Timothy P. Barnett
John Mark O LearyJohn Mark O Leary
John Mark O Leary
TPTimothy D.H. Parkin
Timothy D.H. Parkin
PDPadraic M. Dixon
Padraic M. Dixon
SBSafia Z. Barakzai
Safia Z. Barakzai

23 December 2017 in Veterinary and Comparative Orthopaedics and Traumatology
Verified
Journal Article
Closed access
PDF file
JSJohn David Stack
John David Stack
CRConor Rowan
Conor Rowan
IHIan Handel
Ian Handel
John Mark O LearyJohn Mark O Leary
John Mark O Leary
JJJessica Purefoy Johnson
Jessica Purefoy Johnson
Summary: Objectives: To compare accuracy of the ultrasound-guided craniodorsal (CrD) approach with the dorsal (D) approach to the cervical articular process joints, and to evaluate the effect of the transducer, needle gauge, and operator experience. Methods: Cervical articular process joints from 14 cadaveric neck specimens were injected using either a D or CrD approach, a linear (13 MHx) or microconvex transducer (10 MHz), and an 18 or 20 gauge needle, by an experienced or inexperienced operator. Injectate consisted of an iodinated contrast material solution. Time taken for injection, number of redirects, and retrieval of synovial fluid were recorded. Accuracy was assessed using a scoring system for contrast seen on computed tomography (CT). Results: The successful performance of intraarticular injections of contrast detected by CT using the D (61/68) and CrD (57/64) approaches was comparable. No significant effect of approach, transducer or needle gauge was observed on injection accuracy, time taken to perform injection, or number of redirects. The 18 gauge needle had a positive correlation with retrieval of synovial fluid. A positive learning curve was observed for the inexperienced operator. Clinical relevance: Both approaches to the cervical articular process joints were highly accurate. Ultrasound-guided injection of the cervical articular process joints is an easilylearnt technique for an inexperienced veterinarian. Either approach may be employed in the field with a high level of accuracy, using widely available equipment.

21 August 2012 in Equine Veterinary Journal
Verified
Journal Article
Closed access
PDF file
John Mark O LearyJohn Mark O Leary
John Mark O Leary
TBT. P. Barnett
T. P. Barnett
TPT. D. H. Parkin
T. D. H. Parkin
PDP. M. Dixon
P. M. Dixon
SBS. Z. Barakzai
S. Z. Barakzai

17 May 2011 in Equine Veterinary Education
Verified
Journal Article
Closed access
PDF file
PDP. M. Dixon
P. M. Dixon
John Mark O LearyJohn Mark O Leary
John Mark O Leary